9 Cards in this Set

  • Front
  • Back
TACW Pump Auto Starts

Low Pressure on Running Pump


U1 155 psig, U2 145 psig


*Alarms set 5 psig higher

TACW Pump Trips

Load Conservation


Loadshed


Overload


Overcurrent

TACW Pump Power Supplies

Both Pumps are powered by 600V Train B



TACW Pump flow rates are 8500 gpm U1 and 8800 gpm on U2.

TACW Loads

Bus Duct Cooling


Hydrogen Coolers


Exciter Coolers


Stator Water Coolers



Steam Packing Exhauster (Unit 1)


Gland Steam Condensers (Unit 2)

1-CMO-630

Inlet Valve for Steam Packing Exhauster


Auto Closes on Packing Exhauster's condenser level Extreme High

2-CMO-630, 2-CMO-635

Inlet Valve for Gland Steam Condenser


Associated condensers valve Auto Closes on Gland Steam Condenser level Extreme High

TACW Closed Cycle

1 of 2 TACW pumps takes suction on the common return header and discharge through the TACW Heat Exchanger.



The flow path is then through the parallel loads into a common return header and back to the Pump suction.



Makeup water is supplied through a small bypass line around open cycle shutoff valve c-210, which is closed at this time.



The TACW Heat Exchanger is cooled by circulating water in the heat exchanger tubes.



TACW from Hotwell temperatures >95F on U1 and >104F on U2 must be in closed cycle



--Rejects heat to lake which lowers cycle efficiency

TACW Open Cycle

TACW pump suction is supplied from the hotwell pump discharge header through open cycle shutoff valve C-210.



One of two TACW pumps discharge through Heat Exchanger Bypass Valve CMO-600 the parallel loads.



The flow exits the loads to a common return header and returns to the Hotwell Pumps Discharge Header through the OPEN Cycle Shutoff valve C-249.



++Increases Cycle Efficiency

TACW Modified Open Cycle

Open Cycle WITH TACW Heat Exchanger



Used up to 30% power to reduce overall condensate temperatures (in conjunction with MFP ELOs and Turbine spray).



TACW Heat Exchanger no longer has copper. Some loads do.