Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
24 Cards in this Set
- Front
- Back
- 3rd side (hint)
Tempe Policy 601.01 Station Security Who is responsible for making station security a priority? |
All department members at all times. |
Page 1 |
|
Tempe Policy 601.01 Station Security What time is station "Lockdown"? |
2300: securing all windows and doors |
Page 1 |
|
Tempe Policy 601.01 Station Security When should you change door remote batteries? |
At least quarterly |
Page 1 |
|
Tempe Policy 601.02 Station Care & Maintenance When are fire station & equipment inspected? By whom? |
Semiannually, by District managers |
Page 1 |
|
Tempe Policy 601.03 Facility Maintenance & Reporting Who can submit a facilities service request? |
Any TFMR department member |
Page 1 |
|
Tempe Policy 601.04 Dry Wells @ TTC How must drain valves be set prior to fire training? |
V-1 & V-2 in the closed position, V-3 in the open position. |
Page 1 |
|
Tempe Policy 601.04 Dry Wells @ TTC What position should the valves be following fire training? |
V-1 & V-2 in the open position V-3 in the closed position. |
Page 2 |
|
Tempe Policy 601.04 Dry Wells @ TTC What WILL NOT be used at the training center? |
Foam |
Page 2 |
|
Tempe Policy 602.04 Fire Maintenance Call-Out/ Towing procedures Who do you contact first if you have a maintenance issue after hours? |
The Senior Fire Mechanic |
Page 1 |
|
Tempe Policy 602.04 Fire Maintenance Call-Out/ Towing Procedures If neither of the fire mechanics can be reached whom do you contact? |
Fit our Duty DC |
Page 1 |
|
Tempe Policy 602.04 Fire Maintenance Call-Out/ Towing Procedures If apparatus needs to be towed after hours who do you contact. |
Tempe PD non-emergency |
Page 2 |
|
Tempe Policy 602.04 Fire Maintenance Call-Out/ Towing Procedures What are the approximate size of fire apparatus? |
Pumper:32'/45K lbs Ladder:50'/70K lbs |
Page 2 |
|
Tempe Policy 603.01 Water Distribution System How many water producing facilities does Tempe have? How much can they produce? |
4 facilities producing, 128.5M gallons per day |
Page 1 |
|
Tempe Policy 603.01 Water Distribution System How many water storage facilities does Tempe have? How much water can be stored? |
6 storage facilities Storing 49.7M gallons |
Page 1 |
|
Tempe Policy 603.01 Water Distribution System What is the pressure range for the Tempe water system? |
From 50psi to 95psi |
Page 2 |
|
Tempe Policy 603.01 Water Distribution System What is the fire water flow range in Tempe? |
1K gpm in residential areas, 5K gpm in commercial areas |
Page 2 |
|
Tempe Policy 603.01 Water Distribution System How many hydrants are in Tempe? |
Over 8K |
Page 2 |
|
Tempe Policy 603.01 Water Distribution System What's Tempe's average daily water use and when? |
Between 35-40M gallons, from 0600-1000 & 1600-2200 |
Page 2 |
|
Tempe Policy 603.01 Water Distribution System How far can "Dead-end" hydrants be from their supply source? |
150' |
Page 2 |
|
Tempe Policy 604.01 Uniforms What is the NFPA governing emergency uniforms? |
NFPA 1975 Standard on Emergency Services Work Clothing Elements |
Page 1 |
|
Tempe Policy 604.03 Selection, Care & Maintenance of Firefighting Protective Ensembles What NFPA covers S.C.A.M? |
NFPA 1851 consisting of: Selection, inspection, cleaning, repair, issuing & storage, training, record keeping, retirement & disposition, special incident procedure |
Page 1 |
|
Tempe Policy 604.03Selection, Care & Maintenance of Firefighting Protective Ensembles Per NFPA 1851 how many types of PPE cleaning are there? |
3: Routine Advanced Specialized |
Page 3 |
|
Tempe Policy 604.03Selection, Care & Maintenance of Firefighting Protective Ensembles What temperatures should PPE be stored? |
Between -40°F & 180°F |
Page 5 |
|
Tempe Policy 605.00 Tools/ Equipment Inventory Who is responsible for apparatus equipment inventory? |
Company Officer |
Page 1 |