Bleed air is normally taken from the ___th stage (low pressure)
|
5th
|
|
|
------th stage of the compressor assists during low engine speeds
|
9th
|
|
|
9th stage (high pressure) valve is ____ ________ closed, open at ____, and closes at __ psi.
|
spring loaded
idle 35 |
|
|
The Engine Bleed Valve is __ controlled and uses ____ force to open, _____ force to close
|
DC
pneumatic spring |
|
|
Engine Bleed Valve acts as a ______ _______ and ____ ___ _____
|
Pressur Regulator
Shut-off Valve |
|
|
Engine Bleed Valve gets electrical control from ____ __ and ____ __ busses
|
DC 1
DC 2 |
|
|
Engine Bleed Valve acts as a temperature regulator and closes at ____ F. The _____, _____, and ____ lights illuminate.
|
490F
BLEED TRIP OFF AIR COND MASTER CAUTION |
|
|
The APU Bleed Switch/Valve is __V DC operated off the ____ Bus.
|
28 V
Battery |
|
|
The APU Bleed Valve is able to open into the left duct when APU speed is > ___ RPM
|
95%
|
|
|
Max Pneumatic System Pressure
|
60 PSI
|
|
|
The ______ valve separates the Manifold into left and right sides
|
Isolation
|
|
|
The Isolation Valve is ___ operated and remains in position with a ____ _____.
|
AC
Power Failure |
|
|
When in AUTO with either one or more packs or bleeds off, the isolation valve _____.
|
opens
|
|
|
The Isolation Valve looks at the bleed ______, not the bleed _____.
|
switches
valves It is "switch sensitive" |
|
|
The _____ bleed switch has no effect on isolation valve position
|
APU
|
|
|
Pneumatic Pressure Indicator requires ____ power.
|
AC
|
|
|
Wing Body Overheat
Left Side elements Right Side elements |
Left: engine strut, leading edge, air cond bay, keel beam, APU
Right: engine strut, leading edge, air cond bay |
|
|
Electronic (Analog) Pressure Controller failure causes
|
1) Loss of AUTO AC pwr for more than 15 seconds
2) Cabin ALT 13, 875 ft 3) Excessive cabin rate of change +/- 1800 fpm |
|
|
OFF SCHED DESCENT light causes
(Analog Pressure Controller) |
1) A/C descent prior to cruise
-Controller programs cabin to land at takeoff field elevation |
|
|
OUTFLOW VALVE switch
(Analog Pressure Controller) |
OPEN- opens main cabin outflow valve electrically
CLOSE- closes main cabin outflow valve electrically when in manual mode: full travel 7 sec in AC, 14 sec in DC |
|
|
Digital Pressure Controller failure causes
|
1) loss of DC power
2) pressure controller fault/failure 3) excessive cabin rate of change +/- 2000 fpm 4) Cabin ALT > 15,800 ft |
|
|
OFF SCHED DESCENT light causes
(Digital Pressure Controller) |
1) A/C has started descent at least 1000 ft prior to cruise
-T/O alt is retained in memory and auto controller schedules descent for return to dept airport minus 300 ft |
|
|
Main Outflow Valve is signalled closed if cabin alt exceeds ____ft in AUTO or ALT mode or ___ft in STBY mode.
|
14,500 ft - AUTO or ALT
14,625 ft - STBY mode |
|
|
Flow Control Valve (300/500) is spring loaded open during ____ ____, ____ ___, and ____ ____ below a cabin diff press of approximately ___ psi
|
Ground Operation
Unpressurized Flight Pressurized Flight, 2.5 psi |
Discharges warm air from EE Bay. When valve closes, air is directed around fwd cargo compartment liner for in-flight heating.
|
|
Overboard Exhaust Valve OEV (700) 3 modes
|
Normal Mode
High Flow Mode Smoke Clearance Flow Mode |
Pneumatically controlled pressure regulated air shutoff valve
|
|
OEV Normal Mode
Fully closed when diff press is more than ___psi |
1 psi
|
Exhaust air is then discharged under the fwd cargo compartment floor for inflight heating
|
|
OEV High Flow Mode occurs when (3 conditions)
|
1) Either pack in HIGH
2) Recirc Fan in AUTO 3) Main Outflow Valve has supplied "open enable" cmd |
|
|
OEV Smoke Clearance Flow Mode occurs when (2 conditions)
|
1) Either pack in HIGH
2) Recirc Fan OFF |
28 V DC actuator overrides pneumatic control to open OEV to clear smoke
|
|
Forward Outflow Valve (300/500) closes when Main Outflow Valve is within ___ of full-closed position or ___ ___ is operating.
|
0.5 degrees
recirc fan |
Discharge exit for air circulated around the fwd cargo compartment
|
|
Forward Outflow Valve opens when the Main Outflow Valve opens approx ___, or if the ___ ___ is not operating.
|
4.5 degrees
recirc fan |
Placing the right pack to HIGH turns off recirc fan and opens FOV, adding more fresh air to pressure vessel
|
|
Pressurization Relief Valves limit differential pressure to ___ psi in 300/500 or ___ psi in 700.
|
8.65 psi
9.1 psi |
Vacuum relief valve prevents pressure inside a/c from becoming less than ambient pressure. Can be checked on walk-around by pushing door inward
|