1. What major components of the Manipulator Crane have direction and speed controls available at the control console?
|
Ans. Bridge, Trolley, and Gripper Hoist (fuel mast)
|
|
2. Who must give permission before any interlock can be bypassed?
|
Ans. Refueling SRO
|
|
1. When is the chance of fuel damage the greatest?
|
Ans. When interlocks are bypassed.
|
|
2. How is the chance of fuel damage because of handling minimized?
|
Ans. Operation with interlocks enabled and interlocks are only bypassed with Refueling SRO permission.
|
|
1. List the major components of the Refueling Machine. Reactor Vessel Head and internals with the Polar Crane. Fuel assemblies with the Refueling Machine
|
Ans. Fuel Assembly Gripper, Stationary Mast and Guide Tube, Gripper Hoist, Trolley, and Bridge.
|
|
2. What interlocks on the Refueling Machine are related to the Technical Requirements Manual?Gripper, Mast and Guide tube, Hoist, Trolley, Bridge, Electrical controls, Interlocks and Limit switches
|
Ans. Overload Interlock and Master Overload Interlock. Hoist Overload, Max Overload, and Underload
|
|
3. How are the Overload and Underload settings adjusted for different weight fuel assemblies?
|
Ans. Fuel Selector Switch is selected to the position that corresponds to the type of fuel assembly to be lifted. fuel selector switch on the console
|
|
4. What are the bridge, trolley, and hoist speeds in normal operation and in slow speed zones?
|
Ans. Bridge: 60 / 3 FPM; Trolley: 40 / 3 FPM; Hoist: 21 / 3 FPM Bridge normal 60 FPM; slow speed 3 FPM, Trolley normal 40 FPM; slow speed 3 FPM, Hoist normal 21 FPM; slow speed 3 FPM
|
|
5. The Refuel Machine is located over the lower internal storage area in Zone 3. What is required to move the bridge with the gripper not inside the mast?
|
Ans. The Traverse Interlock prevents bridge or trolley motion when the gripper is not inside the mast and unloaded, this interlock may be bypassed with Refueling SRO permission.
|
|
6. The PLC has detected a difference between the two load cells of 95 lbs. What occurs?
|
Ans. Nothing. A System Fault interlock occurs due to Load Cell comparison error when PLC detects a difference between two load cells is greater than 100 lbs. No effect on operation. Difference greater than 100 lb. would disable bridge, trolley, and hoist motion.
|
|
7. The main hoist is loaded and the operator tries to unlatch the gripper. What happens?
|
Ans. Gripper Unlatch Interlock displays on the Control Console and gripper does not unlatch. Unlatching is also mechanically prevented when hoist is loaded. All motions inhibited due to Gripper Unlatch Interlock.
|