Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
83 Cards in this Set
- Front
- Back
T or F:
Officers and members shall attempt to cause the arrest of any person apprehended transmitting a false alarm. |
True
|
|
The Department on call Fire Investigator shall respond to all fire incidents involving:
|
a. Large loss
b. Fire fatality c. Undetermined, suspicious or incendiary cause |
|
glass that has been heat-treated to give it greater strength than ordinary glass and usually found in side and rear windows. When broken, transforms into hundreds of small cubical pieces.
|
Tempered glass
|
|
For car fires, proper distance to stay away form the car when doing the scene survey?
|
25 feet
|
|
During car fires, how far should the truck be parked from the involved car?
|
75 feet
|
|
Rescue is always the _____ priority after size-up.
|
first
|
|
T or F:
If vehicle is inside or threatens a building, advise Dispatch to send a structure fire response and alter your actions appropriately. |
True
|
|
T or F:
Apply Class “B” foam to leaking fuels such as gasoline or diesel to prevent ignition or to extinguish the fire. |
True
|
|
_____ remove a fuel tank cap because the tank’s contents are under pressure and may spew out resulting in tragic consequences.
|
Never
|
|
Recommended line sizes for minivans, light trucks, SUVs and passenger cars is ___ that has foam capability.
|
1¾”
|
|
T or F:
Work in the area extending from the area between the front bumper and in front of the front tire. |
True
|
|
Over ___ of total loss vehicle fires are arson.
|
50%
|
|
T or F:
Residential units are primarily constructed of Concrete Block and Stucco (CBS), wood frame, composite materials, or combination. |
True
|
|
Electrical shutoffs are required on exterior of residences constructed since the 1990’s and usually located __ _ ___ ____ ___ _________ ______. The shutoff allows the power to be disconnected safely by FLFR personnel and should be turned off anytime there is significant fire involvement. The shutoff may be located and turned off by the crew performing the 360 / walk-around or the Rapid Intervention Team (RIT).
|
in a box near the electric meter
|
|
In the absence of an exterior electrical shutoff, _______ electrical circuits can sometimes be turned off by switching the main circuit breaker to the off position by interior crews.
|
interior
|
|
First arriving engine officer tool assignment:
|
TIC, 6' hook, handlight
|
|
First arriving engine Firefighter tool assignment:
|
Irons, Handlight
|
|
First arriving engine responsibility:
|
1. Stretch initial attack line of the appropriate size
2. Force entry as needed. 3. Search en route to seat of fire. 4. remove victims if found. 5. Extinguish all visible fire. |
|
T or F:
Water application to the fire is usually the most critical action taken on the fire ground. Expeditious application of the correct fire flow, in the proper form, to the correct location during initial fire ground operations will have the greatest impact upon the outcome of a fire. |
True
|
|
Second arriving engine responsibilities:
|
1. Establish water supply
2. Initiate search if not already under way. 3. Stretch back-up hose line if not completed or assist with attack line if needed. 4. Vent fire room or structure if not already initiated. |
|
Second arriving engine Officer tool assignment:
|
TIC, 6' hook, handlight
|
|
Second arriving engine Firefighter tool assignment:
|
Irons, Handlight
|
|
The first arriving ladder LT tool assignment:
|
TIC, 6' hook, handlight
|
|
The first arriving ladder FF tool assignment:
|
Irons, handlight
|
|
The first arriving ladder DE tool assignment:
|
Apparatus, 6' hook, halligan, handlight
|
|
First arriving Rescue tool assignment for fireground ops:
|
CC: hook, handlight
Medic: irons, handlight |
|
T or F:
If the first rescue if assigned to fireground activities, immediately a second rescue will be called to be medical rehab. |
True
|
|
Multiple occupancy dwellings are structures that vary from ___ to _____ stories.
|
one, five
|
|
Method of hoisting a dry hoseline to upper floors of a building with open hallways. The bale of the nozzle is hooked with the head of a hook or pike pole and the hook is handed up to a firefighter on the floor above.
|
Flying hook evolution
|
|
Evolution where a rope is dropped down from the desired floor and used to hoist an attack line to the fire floor. Line hoisted may be a pre-connect from a pumper or a hi-rise pack which may then be supplied via 2.5” supply line.
|
Drop bag evolution
|
|
Evolution where a 2.5" hose is vertically lowered to, or hoisted from, the pumping apparatus to the desired floor and wyed off into one or two 1.75” attack lines.
|
Portable standpipe evolution
|
|
Entire area on face of structure effectively reached by an aerial ladder without repositioning the apparatus. For rear mount aerial apparatus, this area is maximized when backing into position.
|
Scrub area
|
|
Evolution where the hose is stretched vertically up the open shaft or "well" present in many staircases. The "well" in a staircase is the open vertical space that permits a vertical stretch of hose without danger of kinking. This can be performed with 1.75" or 2.5" hose and results in the ability to reach the 4th or 5th floor with a single 50' length of hose.
|
Well Stretch
|
|
T or F:
Although the exterior walls seldom collapse, expect early collapse of the roof and portions of interior construction when exposed to heavy fire. |
True
|
|
______ stairs are the most common and are named so because of their ascend / descent to a half-landing and "return" to continue the ascend / descent to the next floor.
|
Return
|
|
_______ stairs provide a straight run from one floor to another and change direction at each floor.
|
Scissor
|
|
_____-_______ stairs "wrap around" an elevator or open shaft.
|
Wrap-around
|
|
Standpipe systems are typically not required in structures less than __ feet in height
|
50
|
|
Most apartment buildings of three or more stories built since ____ will have sprinklers.
|
1994
|
|
For a multiple occupancy dwelling, the first arriving engine LT tool assignment: |
TIC, 6' hook, handlight, rope bag( if doing drop bag evolution) |
|
FOr a multiple occupancy dwelling, the first arriving engine DE tool assignment:
|
apparatus
|
|
FOr a multiple occupancy dwelling, the first arriving engine FF tool assignment:
|
Irons, handlight
|
|
For a multiple occupancy dwelling, the second arriving engine(water supply) tool asignmnet:
|
Same as first engine.
|
|
For a multiple occupancy dwelling, the third arriving engine has what responsibilty and tool assignments?
|
Attack back up(back up hoseline, ventilation, search).
Lt- TIC, 6' hook, handlight, rope bag DE- apparatus, handlight, halligan, 6' hook FF - Irons, handlight |
|
For multiple occupancy dwelling, the first arriving ladder responsibilties and too assignments?
|
Primary search, ventilation, utilities control.
LT - TIC, 6' hook, handlight DE - apparatus, 6' hook, halligan, handlight FF - Irons, handlight, saw if needed |
|
In multiple story buildings with enclosed hallways and stairwells, the search is prioritized as follows:
|
a. Fire floor.
b. Floor above the fire floor. c. Top floor. d. Floors between top floor and floor above fire, stairwells, and elevators |
|
If refuse accumulated in the trash chute from an overloaded dumpster, a fire originating in the dumpster may spread up the chute. In addition to attacking the dumpster, a hoseline must be stretched to the _______ _____ with fire in the chute to extinguish from above.
|
highest floor
|
|
Windows will not be vented until a ________ hoseline is deployed and manned.
|
charged
|
|
Windows will be vented _____ to advancing the hoseline to the interior.
|
prior
|
|
Large windows will be vented using the reach of a long pike pole or hook and broken at the ___first (in anticipation of plate glass). Although tempered glass is required by code and broken by striking at the bottom, frequently, and illegally, it is replaced with plate glass.
|
top
|
|
A sign of imminent collapse is heavy body of fire which has been burning out of control for __ minutes or more, particularly in a large open floor area.
|
20
|
|
A highrise is a building that is __ feet or greater in height.
|
60
|
|
AN ultra-highrise is a buidling greater than how many stories?
|
40
|
|
A ______ is the space between the ceiling and the floor above that is used for heating ventilation and air conditioning (HVAC) air return, typically found above the public halls and large common areas in commercial buildings.
|
plenum
|
|
Doors in hallways that lead to these electrical rooms generally are _______ ________ doors into the hallway.
|
outward swinging
|
|
_____ _ standpipe systems are designed for Fire Department (FD) use and larger hose streams. They contain 2 ½” outlets and no occupant use hose cabinets. The standpipe outlets will be located in the stairwells.
|
Class 1
|
|
_____ _ standpipe systems are designed for occupant use. They provide 1 ½” outlets with occupant use hose cabinets. These cabinets and their outlets are in the hallways. These outlets are not designed for FD use.
|
Class 2
|
|
_____ _ standppipe systems are designed for both occupant and FD use. Two basic designs require providing the 2 ½” outlets in the stairs in addition to the hose cabinets in the hallways or providing only the hallway hose cabinets equipped with a 2 ½”outlet reduced to 1 ½”.
|
class 3
|
|
HIghrise fire first arriving engine LT tool assignment:
|
TIC, hand light, 75ft. section of 1 ¾” or 50ft. section of 2 ½” attack hose, and a rescue rope bag.
|
|
Highrise fire first arriving engine DE tool assignment:
|
Hand light, 50ft. section of 2 ½” supply hose with high-rise accessory gear bag. The D/E will also carry a set of fire service and elevator keys
|
|
Highrise fire first arriving engine FF tool assignment:
|
Hand light, 75ft. section of 1 ¾“ or 50ft. section of 2 ½“attack hose and irons (flat head axe and Halligan), the irons will be supported using a Milwaukee iron sling.
|
|
Highrise fire second arriving engine(back up) LT, DE, FF tool assignment:
|
Same as first arriving engine if performing back up functions.
|
|
WHen will the second arriving engine on a highrise fire perform water supply?
|
If the first arriving crew advises that the building is equipped with a dry standpipe or lack of water the standpipe
|
|
1 1/2" or 1 3/4" hose is to be tested on what size discharge only?
|
A 2 1/2" discharge with a reducer
|
|
Life saftey rope is __" static kernmantle and has a tensile strength of ______.
|
1/2", 9000
|
|
Lifeline will be limited to a maximum of ____ lbs or __ people.
|
600, 2
|
|
Size and material of utility rope?
|
7/16" static kernmantle
|
|
The months ropes are inspected?
|
Feb, Aug
|
|
tensile strength of class 2 rescue harness?
|
5000 lbs
|
|
Tensile strength of 1" tubular webbing?
|
4000 lbs
|
|
Tensile strength of carabiners and rescue 8 plates?
|
10,000 lbs
|
|
If a carabiner is dropped more than __ feet, it is to be quarantined and permanently removed from service.
|
5
|
|
What months are ladders inspected?
|
June, Dec
|
|
Who is responsible to oversee all training conducted within acquired structures/props? |
Training chief(or designee) |
|
Regarding Salvage/Overhaul, the most valuable asset can be the? |
Owner/manager of the property |
|
If a firefighter cannot be located through a PAR, a _______ must be announced. |
Mayday |
|
Who will be designated the command of the RIT team in the event the team gets activated? |
Incident Safety Officer |
|
FLPD's terminology for "hot zone" in reference to the area of an EOD operation. |
Standoff Area |
|
The standoff are shall be a minimum of ______ in all directions around the hazard area unless otherwise defined by EOD incident commander. |
300 feet |
|
During an EOD operation, it is imperative what be maintained due to the possibility of radio waves triggering an explosive device? |
Radio silence |
|
All personnel on an EOD scene will operate on what radio channel only? |
Simplex |
|
When using the big easy, do no attempt to open any door with a what? |
Side impact airbag |
|
The Broward County Health Department and the City of Fort Lauderdale Environmental Laboratory test The ocean waters when and where? |
Each Monday at: Birch State Park Sebastian Beach Bahia Mar |