Liquid that flows easily, such as gasoline, has a _______ Viscosity?

Low

Hydraulic _______ eliminates the need for complicated system of gears, cams and levers?

Fluid

The main pump draws from the _______ or Low-pressure (LP) accumulators and charge the high-pressure (HP) accumulators or HP tank?

????

If the pressure in the exhaust tank exceeds _____ pounds per square inch gauge (PSIG), the exhaust tank relief valve lifts to discharge air from the exhaust tank

?????

When the main pumps are ______, the filtered and cooled hydraulic fluid is returned to exhaust tank?

?????

Five physical factors that can affect its behavior.

Gravity


Atmosphere


Specified force


Inertia


Friction

Viscosity of flow

The average speed at which the fluid moves past a given point

Viscosity

Measure of a fluids resistance to flow


Low - lose


High - thick

Liquid viscosity is affected by

Changes in temperatures and pressure

Friction tends to oppose?

Motion

Hydraulic on moving parts enables them to?

Move more freely

Factor that impact chemical stability (Oil molecule)

Metal particles


Heat


Oxygen


Water

Factor that impact chemical stability (increasing total acid number TAN)

Acid


Corrosion

Flashpoint

The temperature at which a liquid gives off vapors in sufficient quantity to ignite momentarily or flash when a flame is applied

Fire Point

Temperatures that a distance gives off vapors in sufficient quantity to ignite and continue to burn

Flashpoint minimum temperature vary from _______ degrees for lightest oils to _______ degree for the heaviest oils.

300


510

Four type of hydraulic fluid

Petroleum


Synthetic fire resistant


Water base


Synthetic hydrocarbon

Petroleum-based fluids

Most common used in ships systems

Synthetic fire resistant fluids

MIL-H-19457


Used where fire resistant is required

Which hydraulic fluids are considered hazardous material?

All hydraulic fluids are considered hazardous.

Information regarding hydraulic fluid refer to?

NSTM Chapter 670, volume 2 HMUG Group 12

Hydraulics provide the motive for ________?

ACE Platform

The main pumps and servo pumps continue to operate until the accumulators and the servo control accumulator are?

Fully recharged

Once recharged the main pumps will then _______ until next demand is initiated.

Go off-stroke

In emergency situations what can be used to raise and unload platform or circulate hydraulic fluid through exchanger?

Sump pumps

Belleville spring reseats itself when pressure drops below?

90 PSIG


Amphibious HP point is 150 PSIG


Valve reseat at 135

When the differential pressure exceeds _______ the piston is pushed away from the indicator button decreasing the magnetic pull.

90 PSID


(CVN have the pop up indicators)

Exhaust tanks are designed for use at approximately________PSIG?

200

Exhaust tanks on CVN 73 capacity

2,500 gallons

How many sight gauges, pressure gauges, fluid flow switches Exhaust tank have

Two

Circulation pump and filter assembly

Pumps hydraulic fluid from exhaust tank through the heat exchanger

Circulation pump and filter assembly consists of?

AC Motor


Coupling


Hydraulic pump


Relief Valve


Suction strainer


Filter


Temperatures switch and other valves

CVN circulation pump is _______?


LHA/LHD circulation pump is____?

CVN double cartridge


Amphib is piston pump

Circulation pump relief valve prevent the pressure in the discharge from exceeding

285 PSIG

How many main pumps are there onboard LHA/LHD?

Four ( might be 8)

Regulates pressure in main pump to?

3,300 PSIG

Servo tank assembly is the supply tank for?

Hydraulic motor

CVN ACE has how many lift cables?

20


(8 forward and 12 aft)

Motor operated valves

6” and 10”


Four per ACE on CVN 73