Photovoltaics rely on unique properties of _____ to convert solar radiation directly into electricity

Semiconductors

What factor would typically limit the power output of a photovoltaic array that could be installed on a residential rooftop area?

Area

The energy product of photovoltaic modules and arrays overtime is primarily determined by _____

Irradiation

What is the average solar irradiation on a surface that receives a 4 kilowatt hour per square meter over a 10 hour period

400 W/m²

The peak solar irradiation incident outside the earth's atmosphere is approximately ____ times the nominal peak terrestrial irradiation at sea level

1.3

A horizontal surface generally receive the max amount of solar radiation during??

Summer

A pyranometer is used to measure ____ and _____ solar radiation

Diffuse and direct

Shading analysis is a typical test conducted during a??

Site survey

Large obstruction towards the south side and a present the greatest overall shading effect on a??

Photovoltaic array

A ____ photovoltaic system operates autonomously

Stand alone

Balance of system components consist of wiring, disconnects, switchgear,overcurrent protection, conduit systems and mounting supplies

Know all

___ is the process typically used for applying n-type semiconductors material to n-type silicon wafer

Gas diffusion

In the figure below, A is a short circuit amperage, B is the max current Point, C is the max voltage point, D is open circuit voltage point in it is a maximum power point

Photovoltaic modules are connected in parallel to build ____ and _____ output

Current , power

A unique feature of alternating current photovoltaic modules is

That no Field installable DC wiring is present 690.2 & 690.6(A)

What is the primary distinction between interactive inverters and rotating generators

Rotating generators can act as loads while inverters cannot

IEEE 1547 installations standards apply to photovoltaic and other generators less then ____

10 megawatts

If a 120V inverter output is placed between one ungrounded conductor and the neutral of a 240V system, what is the result?

It adds to the load connected between the neutral and any one ungrounded conductor 705.95(A)