SCOTT SCBA
BACKPACK |
heat treated alum. alloy, chem. resist
adjustable cylinder band auto locking devise when sliding bottle into harness contoured, weight on hips |
|
HARNESS
|
KEVLAR
RETRO-REFLECTED FRONT PATCHES ACCESSORY CLIP ON LEFT SIDE STRAP |
|
WAIST BAND
|
3-POINT SYSTEM
SEATBELT TYPE, TIGHTEN BY PULL'N STRAPS FORWARD SHOULDER STRAPS ARE QUICK RELEASE, PARACHUTE STYLE HARDWARE, TIGHTEN PULL STRAIGHT DOWN |
|
REGULATOR PART ONE
|
SCOTT EASY- FLOW
FLAME RESISTANT HIGH IMPACT PLASTIC locking mount automatic 1/4 TURN counter clockwise INTO FACE PIECE REG IS AUTO ACTIVATED ON 1ST BREATH AIR DIRECTS OVER LENS TO PREVENT FOGGING |
|
REGULATOR PART TWO
|
DELIVERS 160LPM W/ PEAK OF 500LPM
QUICK-DISCONNECT COUPLING HOLDER LEFT SIDE OF BELT PURGE VALE CLOSED @ 1/2 TURN CLOCKWISE POINTER UP |
|
REGULATOR PURGE VALVE DELIVERS
|
125-175LPM
|
|
REGULATOR VIBRALERT
|
END OF SERVICE INDICATOR, AUDIBLE AND TACTILE, CAN BE HEARD AND FELT ON FACE PIECE. AIR IS DIRECTED BACK INTO REGULATOR, NO WASTED AIR
|
|
SCOTT PRESSURE REDUCER 4.5
|
LOCATED ON LEFT SIDE, REDUNDANT SYSTEM
Primary -supplies air to reg during normal use. Secondary -if 1st becomes clogged or fails in the closed position the secondary will automatically supply air & end of service is activated |
|
SCOTT SCBA - GAUGE
|
READS IN 1/4 INCERMENTS (X 100)
GREEN 4000-4500 "FULL" RED 0-500 " EMPTY" ILLUMINATES UP TO 2 HRS WHEN EXPOSED TO LIGHT |
|
SEMS UNIT WITH INTEGRATED P.A.S.S.
|
TURNS ON WHEN BOTTLE IS ON
NEEDS AT LEAST 80 PSI TO ACTIVATE MANUAL TURN ON PRESS RED BUTTON yellow twice for reset |
|
SEMS SELF- TEST
|
FLASHING GREEN LIGHT
3 AUDIBLE CHIRPS 4 ARROWS ARROWS DISSAPPEAR WHEN SIGNED ON TO A BASE UNIT |
|
SEMS PRE-ALARM/ ALARM
|
AFTER 20 SEC OF NON-MOVEMENT
FLASHING RED , AUDIBLE CHIRP (CAN RESET BY MOVEMENT OR YELLOW BUTTON 2X) RAMP UP 10 SEC LATER, RED LIGHTS, CONSTANT 3 TONE ALARM ( CAN BE RESET W/ YELLOW BUTTON 2X) |
|
ALARM-
TONE dba's SPEAKERS |
DUAL AUDIBLE 3 TONE ALARM
95 dba's TWO SPEAKERS IN CASE ONE IS BLOCKED |
|
BATTERIES
|
3- 9 VOLT
ONE IN THE SEMS TWO IN THE AUDIBLE BATTERIES DEFAULT TO GOOD BATTERIES AS THEY BECOME DISCHARGED |
|
BATTERY OPERATIONAL LIFE
|
20 HRS
|
|
CHECKING BATTERY STATUS
WITH CYLINDER OFF |
HOLD DOWN YELLOW BUTTON
GREEN LED "OK" RED = DEAD |
|
ACTIVATED PASS SOUNDS FOR?
|
3HRS UNLESS RESET
|
|
PASS IS MANUALLY ACTIVATED BY
|
HOLDING RED BUTTON
|
|
1/2 TANK WARNING
|
4 CHIRPS
1/2 DISPLAYED IN VISUAL WINDOW |
|
AIR PRESSURE DISPLAY
|
HOLD YELLOW BUTTON
|
|
LOW AIR WARNING
|
@ 1,125, LED DISPLAYS"LOW" THEN "AIR" THEN REMAINING AIR PRESSURE WITH ASSOCIATED CHIRPS
|
|
ONCE LOW AIR GOES OFF
|
UNIT CAN'T BE RESET UNTIL BOTTLE IS TURNED OFF, AND AIR IS BLED
THEN PRESS YELLOW RESET 2X DISPLAY WILL SHOW OFF |
|
EVACUATION CAN BE SENT BY
|
BASE STATION
THREE LONG TONES REPEATED EVERY THREE SECONDS |
|
ACKNOWLEDGING EVACUATION
|
YELLOW RESET BUTTON TWICE
|
|
AFTER ACKNOWLEDGING EVACUATION
TONES WILL BE |
PUT ON A 60 SECOND DELAY
EVACUATE WILL BE DISPLAYED IN DIGITAL WINDOW UNTIL SHUT DOWN |
|
SEMS UNIT ALLOWS INFO TO BE EXCHANGED BETWEEN COMMAND AND INDIVIDUAL FF'S THROUGH?
|
TRANSCEIVER TECHNOLOGY
|
|
SEMS UNIT MONITORS?
|
WHOS SCBA IS ACTIVATED, CURRENT TANK PRESSURE, A UNIT NEEDS ASSISTANCE, LOW AIR WARNINGS, NEW CYLINDER, FF IMMOBILITY, SELF EVAC OR INJURY, EVAC CAN GO TO AN INDIVIDUAL OR ALL UNITS.
LOGS UP TO 48 FF"S, TRACKS UP TO 100 |
|
EBSS DEFINITION
|
EMERGENCY BREATHING SUPPORT SYSTEM
|
|
EBSS HOSE LENGTH
|
3 FT
|
|
EBSS STORAGE
|
left belt, secured w/ either a 1/4 turn manifold retainer or pocket
|
|
EBSS CONNECTIONS
|
DUAL MANIFOLD, W/ MALE/ FEMALE QUICK DISCONNECTS ( EITHER ONE MAY BE USED TO SUPPLY OR RECEIVE AIR)
|
|
EBSS CONNECTIONS ARE PRESSURIZED TO
|
160 PSI
|
|
FACE PIECE
|
SCOTT AV 3000
|
|
FACE PIECE SEAL
|
EPDM NATURAL RUBBER SEAL BLEND
|
|
FACE PIECE LENS
|
POLY-CARBINATE LENS WITH SCRATCH RESISTANT EXTERIOR, ANTI-FOG INTERIOR
|