What command shows a effective zones and configurations in Brocade?
zoneShow/cfgShow
Sorry, No Hint Available.
What command add a member to a zone in Brocade?
zoneAdd
Sorry, No Hint Available.
What command removes a member from a zone in Brocade?
zoneRemove
Sorry, No Hint Available.
What command deletes a zone in Brocade?
zoneDelete
Sorry, No Hint Available.
What command adds a zone to a zone configuration in Brocade?
cfgAdd
Sorry, No Hint Available.
What command saves a defined config to all switches in a fabric across reboots in Brocade?
cfgSave
Sorry, No Hint Available.
What command removes a zone from a zone configuration in Brocade?
cfgRemove
Sorry, No Hint Available.
What command deletes a zone from a zone configuration in Brocade?
cfgDelete
Sorry, No Hint Available.
What command clears all zoning information and must be disabled the effective configuration in Brocade?
cfgClear
Sorry, No Hint Available.
What command disables the effective zone configuration in Brocade?
cfgDisable
Sorry, No Hint Available.
What command creates a zone in Brocade?
zoneCreate
Sorry, No Hint Available.
What command creates a zone configuration in Brocade?
zoneCreate
Sorry, No Hint Available.
What command enables a zone configuration in Brocade?
cfgEnable
Sorry, No Hint Available.
What command actively shows the connected running zoneset in McData?
showActive
Sorry, No Hint Available.
What command clears the WWNs in a zone in McData?
clearZone
Sorry, No Hint Available.
What are the Management Options for McData Switches?
SNMP, Telnet, Serial, EWS, Connectrix Manager
Sorry, No Hint Available.
What command removes a zone from the running config in McData?
deleteZone
Sorry, No Hint Available.
What command activates a zoneset of changes in McData?
activateZoneset
Sorry, No Hint Available.
What command adds a new zone to the working area in McData?
addZone
Sorry, No Hint Available.
What command associates a WWN with a zone in McData?
addWWNmem: <zonename> <wwn>
Sorry, No Hint Available.
What command shows pending zones in McData?
showPending
Sorry, No Hint Available.
What command deletes a WWN from a zone in McData?
deleteWWNmem: <zonename> <wwn>
Sorry, No Hint Available.
What command renames a zoneset in McData?
renameZoneSet
Sorry, No Hint Available.
What are the management options for Cisco MDS?
SNMP, Telnet SSH, Serial Console, Fabric Manager/Device Manager.
Sorry, No Hint Available.
What command copies from source to startup configuration on Cisco MDS?
COPY running-config start-up config
Sorry, No Hint Available.
What command goes into vsan configuration mode in Cisco MDS?
vsan database
Sorry, No Hint Available.
What command creates a zone in Cisco MDS?
zone name <name> vsan <#>
Sorry, No Hint Available.
What command creates a zoneset in Cisco MDS?
zoneset name <name> vsan <#>
Sorry, No Hint Available.
What command shows all zonesets that are active?
show zoneset
Sorry, No Hint Available.
What commands shows all zones active in a vsan in Cisco MDS?
show zone vsan <#>
Sorry, No Hint Available.
What command displays the active zoneset in Cisco MDS?
show zoneset active
Sorry, No Hint Available.
What command shows the vsans on a Cisco MDS switch?
show vsan
Sorry, No Hint Available.
What are the Management options for Brocade?
SNMP, Telnet, Serial, Webtools
Sorry, No Hint Available.
What is the telnet command that lists the logins on Connectrix in Brocade?
switchshow /nsshow
Always one word.
What the the telnet command that lists the logins on Connectrix in McData?
show> loginserver
Only command with > in.
What is the telnet command that lists the logins on Connectrix in Cisco MDS?
show fcns database
Always starts with show.
What is the telnet command that lists logins to the fabric on Connectrix in Brocade?
nsallshow / fabric show
Sorry, No Hint Available.
What is the telnet command that lists logins to the fabric on Connectrix in McData?
show> nameserver
Sorry, No Hint Available.
What is the telnet command that lists logins to the fabric on Connectrix in Cisco MDS?
show flogi database
Sorry, No Hint Available.
What is the telnet command that lists IP addresses on Connectrix in Brocade?
ipaddrshow
Sorry, No Hint Available.
What is the telnet command that lists IP addresses on Connectrix in McData?
config ip show
Sorry, No Hint Available.
What is the telnet command that lists IP addresses on Connectrix in Cisco MDS?
show running-config
Sorry, No Hint Available.
What is the telnet command to list Domain IDs on Connectrix in Brocade?
switchshow
Sorry, No Hint Available.
What is the telnet command to list Domain IDs on Connectrix in McData?
show> switch
Sorry, No Hint Available.
What is the telnet command to list Domain IDs on Connectrix in Cisco?
show running-config
Sorry, No Hint Available.
What ECC agents are needed for zoning and LUN masking in SYMM in Clariion?
Master Agent, SDM, FCC, Clariion Agent, Symmetrix Agent.
MSFCS
What is the SYMCLI command to add a lun masking entry to the VCMDB?
Symmask add devs
Sorry, No Hint Available.
What is the SYMCLI command to backup the VCMDB?
Symmaskdb backup
Sorry, No Hint Available.
What is the SYMCLI command to list all devices in a symm?
Symdev list
Sorry, No Hint Available.
What are the 3 EMC commands to list devices mapped to your host?
syminq, sympd list, inq
Sorry, No Hint Available.
What are the management options for the Symm?
ECC and Solutions Enabler
Sorry, No Hint Available.
What are the management options for for the Clariion?
Navisphere Manager and NaviCLI
Sorry, No Hint Available.
What software needs to be enabled on a Clariion for LUN masking?
Access Logix
Sorry, No Hint Available.
What connectrix has a service processor?
McData
Sorry, No Hint Available.
What Connectrix uses the multi-protocol services module?
Cisco MDS
Sorry, No Hint Available.
What proprietary technologies are used to logically aggregate ISLs?
Trunking (Brocade/McData)
Port channelling /ISL Aggregation (Cisco)
Sorry, No Hint Available.
What is RA-TOV? (see hint.)
Resource Allocation Time Out Value
Resources are allocated to a circuit when an error is detected and are not released until the time specified by the RA-TOV.
What is a default zone?
Zone that contains all the ports that are not allocated to a zone.
If you are not in zone, you are in the default zone.
List 2 iSCSI storage models.
Native (plugged directly)
Bridged (uses a gateway)
Sorry, No Hint Available.
How far can DWDM span?
Less than 200km.
Sorry, No Hint Available.
What is a principle switch?
The switch in charge of the fabric that holds the master copy of the login table and propagates the information to the other switches. Tells other switches to change their domain IDs.
Sorry, No Hint Available.
What is Over-Subscription Ratio?
Number of N ports using ISL links.
Sorry, No Hint Available.
What is FAN OUT?
One storage port, many hosts.
Sorry, No Hint Available.
What is FAN IN?
One Host, many storage ports.
Sorry, No Hint Available.
List 3 SAN topologies.
Single, Mirrored, Balanced, Meshed, Core Edge, and Compound Core Edge.
Sorry, No Hint Available.
Where do you see evidence of logins in Windows
Event Viewer (Fabric), Driver Conf Utility (Port), Device Manager (Disks)
Sorry, No Hint Available.
What do you see evidence of logins in UNIX?
Messages Files
Sorry, No Hint Available.
What protocols are used on FC SAN?
SCSI, IP, SCSI over IP (FCP)
Sorry, No Hint Available.
How many bits & characters are in a WWN?
WWN 64 bits / 16char
Sorry, No Hint Available.
How many bits & characters are in a FCID?
FCID: 24 bits / 6 char
Sorry, No Hint Available.
List the 3 FC Logins.
FLOGI, PLOGI, Process Login
Sorry, No Hint Available.
List the 3 FC common services.
Login, Name, Fabric Controller
Sorry, No Hint Available.
Name the 5 FC layers from FC0-FC04.
Physical, Encoding, Flow Control/Framing, Common Services, Upper Layer Protocols mapped.
P.E.F.C.U.