What is rod speed for control banks in manual?

36 SPM.

What is rod speed for control banks in auto based on?

Temp Error = Tave - Tref

What is rod speed for shutdown banks?

64 SPM.

What does 0-100% correlate to on


PT-485?

0-664 psig.

What does the Logic Cabinet consist of?

Pulser


-


Master Cycler


-


Bank Overlap Unit


-


Slave Cycler

What does the Pulser control?

Controls the rate of rod steps.

What does the Master Cycler control?

Initiates GO signals at zero and three.


-


Zero is for group 1's.


-


Three is for group 2's.

What does the Bank Overlap Unit do?

Designates which BANK receives the GO signal.

What does the Slave Cycler do?

Generates stationary, movable, and lift current for rod movement based on GO signal.

When does the Bank Overlap Unit count?

Only in auto or manual.


-


Not in bank select.

Explain what each Power Cabinet controls.

1AC: Group 1 of Control Banks A and C; and Shutdown Bank A.


-


1BD: Control Banks B and D; and Shutdown Bank B (these banks only have 1 group each).


-


2AC: Group 2 of Control Banks A and C; and Shutdown Bank A.


At what point does turbine first stage pressure prevent rod withdrawal?

AUTO rod withdrawal is prevented <15%.


-


MANUAL rod withdrawal is still possible for start up.

What are the Auto and Manual Rod Stops?

Power Range: 1/4 > or = 104%


-


Intermediate Range: 1/2 ~23%


-


OP delta T: 2/4 1.5F


-


OT delta T: 2/4 3.0F

What are the required alignment limits for individual rod positions?

Plus or minus 18 steps of demanded position in mode 1 >85 % RTP; when bank demand position is < 215 steps.


-


Plus or minus 24 steps of demanded position in mode 1 >85% RTP; when demanded position is 215 steps or more.


-


Plus or minus 24 steps of demanded position in mode 1 < or equal to 85% or mode 2.