Types of Snapshots and Data Protection?

Crash consistent & Application consistent

A backup or snapshot is ____________ if all the interrelated data components are as they were (write-order consistent) at the instant of the crash.

Crash consistent

A backup or snapshot is ____________ if, in addition to being write-order consistent, running applications have completed all their operations and flushed their buffers to disk.

Application consistent

Snapshots can be configured on what schedule?

Hourly, daily, weekly in a snapshot policy.

SteelFusion Edge interacts with both VMware tools and VSS. What data drives can you take backups and snapshots of?

VMFS & NTFS

A physical SteelFusion Core supports the following network/storage protocols?

iSCSI

A virtual SteelFusion Core supports the following network/storage protocols?

iSCSI & FC

Type of Core VE Fibre Channel LUNs?

FC with RDM (Fiber Channel with Raw Device Mapping)

Fibre Channel LUNs are distinct from iSCSI LUNs in these ways:

- No MIPO


- SCSI reservations are not taken on the FC LUNs


- Additional HA configuration required, each appliance must be deployed on a seperate ESXi system for failover peers


- Maximum 60 Fibre Channel LUNs per ESXi system, ESXi allows a max of 60 RDMs into a VM. Within the VM an RDM is presented as a virtual SCSI device.

Where do you configure LUNs in the Core?

Configure -> Manage -> LUNs

Where do you configure iSCSI?

Configure -> Storage Array -> ISCSI, Initiators, MPIO

The Edge is what type?


- iSCSI target


- iSCSI portal


- iSCSI initiator

iSCSI target - as the edge holds the data.

How many Cores can be configured in one pool?

32

SteelFusion Core has deep snapshot integration with what vendors?

EMC, Dell & NetAPP

Which port is used for management in the SteelFusion Core & Edge?

7970

What file systems would benefit most of pinning a LUN?

EXT3 & FAT32

The Edge functions as what SAN component?

Cache

The information required for configuring a SteelFusion Edge in the Core is?

The Edge identifier