  • Back

Special fresh air ventilation fittings must be used to connect the fresh air duct to the return trunk duct. true or false

false

The combustion air termination is used to:




a) finish the combustion air duct neatly


b) add to the cost of the job


c) provide a secure mounting point for the end of the combustion air duct


d) keep cold air from dropping into the furnace room.

d) keep cold air from dropping into the furnace room.

Both factory built chimneys and vents have a system of parts that are _______ by a recognized testing agency.

certified

Installations requiring you to run forced air heating under the concrete slab are known as:




a) spiral heating


b) underslab heating


c) underground heating


d) under concrete heating

b) underslab heating

Roof jacks used on dryer vents are available without which of the following?




a) flaps


b) dampers


c) bird screens


d) springs

c) bird screens

What is the fitting used to connect the return air branch runs to the main duct called?




a) return take-off


b) liner connector


c) branch connector


d) none of the above

d) none of the above

The material used for venting of the fan to the outside must be metal duct with insulation and a vapour barrier, such as foilback insulation. True or false?

false

Furnaces require air to fuel the fire in side of them. This is called ______ air.

combustion air

The entire underslab ducting system must slope ______ the furnace.




a) back to


b) level with


c) away from



a) back to

When a return air branch run is finished on the bottom with a drywall ceiling, the bottom of the branch run is finished with:




a) light gauge metal


b) thermopan


c) plastic


d) drywall

d) drywall

____________ is the uncontrolled leakage of air from a building.

Exfiltration

What does a type L-vent construction consist of?




a) an outer casing of Galvalume / airspace / inner liner of aluminum


b) an outer casing of Galvalume, air space, inner liner of stainless steel


c) an outer casing of stainless steel / airspace/ inner liner of stainless steel


d) an outer casing of stainless steel / insulation / inner liner of stainless steel

b) an outer casing of Galvalume, air space, inner liner of stainless steel

The ductwork coming off the plenum for underground heating installations will be ____________ for strength and to make it easier to seal against moisture in the ground.




a) round


b) rectangular

a) round

A 14 x 8 return air grill:




a) is 14" wide by 8" high


b) is 14" high by 8" wide


c) covers an 14" by 8" hole


d) has a free area of 14" x 8"

c) covers an 14" by 8" hole

What is the heart of the heating, ventilation, and air-conditioning (HVAC) systems?




a) the furnace heat exchanger


b) the air recirculation fan


c) the furnace plenum


d) the gas valve and burners

b) the air recirculation fan

The air is ________ from the central heating or cooling unit by the supply air system.

distributed

The return air part of an HVAC system consists of the parts to bring air back from the _____ to the furnace.

occupied space

Rectangular duct takeoffs include all of the following except:




a) top take offs


b) side take offs


c) universal take offs


d) saddle take offs

d) saddle take offs

The ratio between the width and depth of duct should never exceed:

4:1

Name 4 things that can cause dynamic loss in an airstream

1. material duct is constructed from ( smooth or rough)


2. the shape of the duct


3. changes in direction


4. Changes in cross sectional area

Dynamic losses on flexible duct are approximately ____ times as great per foot as in smooth duct.




a) 4


b) 7


c) 10


d) 12

10

Dynamic losses occur in both rectangular and round duct. True or false?

true

You should always install 2 elbows together (back to back) True or false?