AC Single Rail
SLV 12/13 25 Hz |
Relay End: 3 - 5 VAC 1 - 1.9 A
Feed End: 7 - 9 VAC 3A |
|
|
AC Single Rail (WSSY)
GRS B2 Vane
100 Hz |
Relay End: 1 - 1.5 VAC .75 - 1.4 A
Feed End: 4 - 6 VAC 2 A |
|
|
AC Single Rail (Brook/Hall)
PV 250
100 Hz |
Relay End: .75 - .9 VAC .95 - 1.2 A |
|
|
AC Double Rail
Model 15 25 Hz |
Relay End: .25 - .45 VAC 1 - 1.5 VAC
Feed End: 8 - 12 VAC 12 - 18 A |
|
|
AC Double Rail Model 15 100 Hz |
Relay End: . 5 - 1.5 VAC 1 - 1.9 A
Feed End: 6 - 8 VAC 7 - 12 A |
|
|
AC Double Rail PV 250 25 Hz |
Relay End: . 3 - .6 VAC . 9 - 1.9 A Feed End: 8 - 12 VAC 12 - 18 A |
|
|
AC Double Rail PV 250 100 Hz |
Relay End: . 5 - 1.3 VAC . 8 - 1.7 A Feed End: 6 - 8 VAC 7 - 12 A |
|
|
AC Double Rail
GRS B2 Vane
100 Hz |
Relay End: . 8 - 1.5 VAC . 7 - 1.3 A
Feed End: 6 - 8 VAC 7 - 12 A |
|
|
AC Double Rail
Safetran
100 Hz |
Relay End: . 8 - 1.5 VAC . 7 - 1.3 A
Feed End: 6 - 8 VAC 7 - 12 A |
|
|
AC Double Rail ST 450 593 100 Hz |
Relay end: .8 - 1.5 VAC .7 - 1.3 A Feed end: 6 - 8 VAC 7 - 12 A |
|
|
AC Double Rail (Port Jeff) East of Post 2 (no bonds)
GRS B2 Vane
100 Hz |
Relay end: .7 - 1.2 VAC .9 - 1.3 A
Feed end: 3.3 - 5 VAC 2.9 - 3.7 A |
|
|
DC DN-11 .5 Ohm |
Relay end: .3 VDC Amperage set to 33% over last pick up value Feed end: Set to battery voltage |
|
|
DC PD-1 1 Ohm |
Relay end: .4 VDC Amperage set to 33% over last pick up value Feed end: Set to battery voltage |
|
|
DC PN-150 BTR 2 Ohm |
Relay end: .5 VDC Amperage set to 33% over last pick up value Feed end: Set to battery voltage |
|
|
DC DN-22 BH 4 Ohm |
Relay end: .5 VDC Amperage set to 33% over last pick up value Feed end: Set to battery voltage |
|
|
Type C DN-11 .5 Ohm |
Relay end: 1-1.5 VDC Amperage set to 110% over last pick up value Feed end: 6.3 VAC 3.5 A |
*All Type C relays are the same *Feed end is HX-1 output |
|
Type C
PD-1
1 Ohm |
Relay end: 1-1.5 VDC Amperage set to 110% over last pick up value Feed end: 6.3 VAC 3.5 A |
*All Type C relays are the same *Feed end is HX-1 output |
|
Type C
PN-150 BTR
2 Ohm |
Relay end: 1-1.5 VDC Amperage set to 110% over last pick up value Feed end: 6.3 VAC 3.5 A |
*All Type C relays are the same *Feed end is HX-1 output |
|
Type C
DN-22 BH
4 Ohm |
Relay end: 1-1.5 VDC Amperage set to 110% over last pick up value Feed end: 6.3 VAC 3.5 A |
*All Type C relays are the same *Feed end is HX-1 output |