- Front
- Back
During refueling, the pools are classified as ______
|
FME Zone 1
|
|
In FME areas control and accountability of FME zones is accomplished by using what?
|
Lanyards or fail safe devices, FME devices, Logging and tracking items, and continuous physical control.
|
|
What should happen if material is dropped into the pool?
|
1. observe closely to identify exact final location
2. notify supervisor 3. RP assistance 4. Initiate a condition report |
|
If the Fuel prep machine is set up to handle new fuel, install a sign on the FPM handrail with the following information.
-? -? |
-New fuel handling only
-do not place irradiated fuel in this machine |
|
FPM stands for what?
|
Fuel Prep Machine
|
|
FPM operations with irradiated fuel is prohibited with what?
|
any lower pool drained
|
|
If the FPM is left unattended with an irradiated bundle it must be ...?
|
in the full down position and the air supplu off and in the locked position.
|
|
___ shall monitior all items being removed from the spent fuel pool.
|
RP
|
|
Anytime visual indication is lost in the SFP....?
|
immediately cease all movements
|
|
______ with handling nuclear fuel is responsible for being familiar with and directly adhering to the rules outlined in this procedure for preventing inadvertent criticalities
|
Each person involved
|
|
All fire hose nozzles in the fuel handling are shall be
_______ during Fuel Receipt |
Streaming Nozzles
|
|
Loads in excess of _____ shall be prohibited from travel over the fuel assemblies in the spent or new fuel storage, transfer or upper containment fuel pool racks
|
1200 lbs
|
|
When completing an STS, the ___ signs as the performer: the _____ signs as the verifier.
|
driver/spotter
|
|
Fuel that has occupied part of a critical reactor core within 24 hours is called what?
|
Irradiated fuel
|
|
Before breaking the plane you need permission from who?
|
Refuel SRO
|
|
AOP-0027 symptoms summary?
|
-bundle drops or strikes a fixed object
-gas bubbles escaping from spent fuel -high airborne activity -unplanned lowering of pool level -malfunction of IFTS when loaded with irradiated fuel. -Observation of rising neutron count rate |
|
What are the immediate operator action in AOP-0027?
|
NONE
|
|
What are the subsequent actions of AOP-0027?
|
1. stop all refueling activities
2. evacuate affected areas 3. motify MCR 4. If a bundle or irradiated device is in transit, then place it in a safe position using the appropriate attachment 5. If IFTS is fuel loaded, place in either upper or lower pool. (LOWER POOL PREFERRED) 6. A problem with IFTS containing spent fuel may require cooling water withing 30 minutes. |
|
A problem with IFTS containing spent fuel may require cooling water withing ______
|
30 minutes.
|