  • Front
  • Back
During refueling, the pools are classified as ______
FME Zone 1
In FME areas control and accountability of FME zones is accomplished by using what?
Lanyards or fail safe devices, FME devices, Logging and tracking items, and continuous physical control.
What should happen if material is dropped into the pool?
1. observe closely to identify exact final location
2. notify supervisor
3. RP assistance
4. Initiate a condition report
If the Fuel prep machine is set up to handle new fuel, install a sign on the FPM handrail with the following information.

-?
-?
-New fuel handling only
-do not place irradiated fuel in this machine
FPM stands for what?
Fuel Prep Machine
FPM operations with irradiated fuel is prohibited with what?
any lower pool drained
If the FPM is left unattended with an irradiated bundle it must be ...?
in the full down position and the air supplu off and in the locked position.
___ shall monitior all items being removed from the spent fuel pool.
RP
Anytime visual indication is lost in the SFP....?
immediately cease all movements
______ with handling nuclear fuel is responsible for being familiar with and directly adhering to the rules outlined in this procedure for preventing inadvertent criticalities
Each person involved
All fire hose nozzles in the fuel handling are shall be
_______ during Fuel Receipt
Streaming Nozzles
Loads in excess of _____ shall be prohibited from travel over the fuel assemblies in the spent or new fuel storage, transfer or upper containment fuel pool racks
1200 lbs
When completing an STS, the ___ signs as the performer: the _____ signs as the verifier.
driver/spotter
Fuel that has occupied part of a critical reactor core within 24 hours is called what?
Irradiated fuel
Before breaking the plane you need permission from who?
Refuel SRO
AOP-0027 symptoms summary?
-bundle drops or strikes a fixed object
-gas bubbles escaping from spent fuel
-high airborne activity
-unplanned lowering of pool level
-malfunction of IFTS when loaded with irradiated fuel.
-Observation of rising neutron count rate
What are the immediate operator action in AOP-0027?
NONE
What are the subsequent actions of AOP-0027?
1. stop all refueling activities
2. evacuate affected areas
3. motify MCR
4. If a bundle or irradiated device is in transit, then place it in a safe position using the appropriate attachment
5. If IFTS is fuel loaded, place in either upper or lower pool. (LOWER POOL PREFERRED)
6. A problem with IFTS containing spent fuel may require cooling water withing 30 minutes.
A problem with IFTS containing spent fuel may require cooling water withing ______
30 minutes.