Patrol 6 foam systems light blinks and then goes out
|
System is on and ready to operate
|
|
Patrol 6 Foam system light stays on
|
System is on but insufficient foam concentrate to operate
|
|
Patrol 6 foam system no light during startup
|
No power / insufficient power to unit
|
|
Patrol 6 foam system light blinks once per second
|
A low concentrate has been detected. *The light will blink for two minutes, and then shut off the foam pump unless adequate foam level is restored.
|
|
Patrol 6 foam system Light is solid after successful start up and operation
|
System had been out of foam for more than 2 minutes and the foam pump is not operating
|
|
Patrol 6 foam system light blinks 5 times per second
|
No pump feedback is detected and a problem exists at the speed sensor.
|
|
Drafting and priming issues and troubleshooting for Type 3
|
-Air leak from a loose hose connection, an open or leaking valve, or dried out packing
-Defective primer or priming valve -Blockage in the suction hose or strainer -Insufficient water depth around the strainer, which can cause a -whirlpool to develop -Primer oil reservoir is empty -Priming oil line vent hole is blocked -Primer has not run for 30 seconds -Suction hose is collapsing internally -Discharge valve was opened too quickly -Engine RPM were raised too quickly -Suction hose is elevated above eye of the pump forming an air pocket -Too much lift (greater than 15 feet) |