• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/132

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

132 Cards in this Set

  • Front
  • Back
COAMING
A RAISED FRAME TO KEEP OUT WATER
DISTILLATION
THE TOTAL PROCESS THE DISTILLING PLANT FORMS, INCLUDING EVAPORATION AND CONDENSATION.
(FAC) FREE AVAILABLE CHLORINE
CHLORINE AVAILABLE IN THE FORMS OF HYPOCHLORUS ACIS AND HYPOCHLORITE IONS.
MICRON
A UNIT OF LENGTH. ONE MILLIONTH OF A METER.
POINT OF USE (POU)
SINGLE TAP TREATMENT DEVICE USED TO REDUCE TAP WATER CONTAMINANTS.
POTABLE WATER
WATER SUITABLE FOR HUMAN CONSUMPTION
REVERSE OSMOSIS (RO)
REVERSE OF NATURAL OSMOSIS, APPLICATION OF REVERSE PRESSURE TO CAUSE FLOW IN UNNATURAL DIRECTION.
COLILERT/ COLISURE
TEST USED TO DETECT TOTAL COLIDORM AND E-COLI IN POTABLE WATER.
TOTAL COLIFORM
HARMLESS BACTERIA THAT LIVES IN SOIL, WATER AND ANIMAL GUTS.
E. COLI
ESCHERICHIA COLI

TYPE OF FECAL COLIFORM BACTERIA FOUND IN ANIMAL AND HUMAN INTESTINES.
NAVSEASYSCOM
SHIPBOARD POTABLE WATER SYSTEMS
TREATMENT FACILITIES AND
PROCESSES
NAVSEASYSCOM
DESIGN

CONSTRUCTION

MAINTENANCE
NAVFAENGCOM
PROMULGATING INSTRUCTIONS FOR SHIP-TO-SHORE POTABLE WATER CONNECTIONS & PROVIDING APPROVED SOURCE FOR POTABLE WATER.
CHIEF, BUMED
ESTABLISHING AND PROMULGATING HEALTH STANDARDS
PROMULGATE APPROPRIATE INSTRUCTIONS, NOTICES OR OTHER PUBLICATIONS AFLOAT
ESTABLISH SHIPBOARD REQUIREMENTS FOR MEDICAL SURVEILLANCE
AREA, FLEET & SUBORDINATE COMMANDERS
ISSUING AND IMPLEMENTING DIRECTIVES, ENSURE ADEQUATE WATER SANITATION STANDARDS ARE PROVIDED AND ENFORCED IN EACH SHIP.
COMMANDING OFFICERS
PROMULGATING WATER SANITATION BILL, PROCEDURES FOR RE EIPT, TRANSFER, TREATMENT, STORAGE, DISTRIBUTION AND SURVEILLANCE
ENGENEERING DEPARTMENT
RESPONSIBLE TO COMMANDING OFFICER FOR IMPLEMENTING REQUIREMENTS OF NAVSEASYSCOM
ENGINEERING DEPARTMENT
SUPPLY AND TREATMENT OF POTABLE WATER
POTABLE WATER COMPONENTS
RECEIVE

STORE

DISTRIBUTE

PRODUCE

TREAT
ENGINEERING DEPARTMENT
ENSURE SHIP-TO-SHORE AND SHIP-TO-SHIP CONNECTIONS ARE MADE BY AUTHORIZED PERSONNEL, WHEN AVAILABLE, OR SHIP PERSONNEL PROPERLY SUPERVISED BY AUTHORIZED PERSONNEL.
ENGINEERING TESTING
HALOGEN AND PH TESTING
ENGINEERING DEPARTMENT
ENSURE MINIMUM RESIDUALS ARE MAINTAINED BEFORE PLACING TANK ONLINE FOR DISTRIBUTUION.
MEDICAL DEPARTMENT REPRESENATIVE (MDR)
RESPONSIBLE FOR CONDUCTING A MEDICAL SURVEILLANCE PROGRAM OF POTABLE WATER SYSTEM.
MDR
BACTI TESTING

DAILY HALOGEN TESTING

NOTIFY CO OF WATER DISTRIBUTION SYSTEM DISCREPANCIES
MINIMUM USAGE REQUIREMENTS
NEW SHIP- 50 GALLONS PER MAN, PER DAY SPECIFIED BY NAVSEA
WATER HOURS
MINIMUM USAGE DOES NOT APPLY
NOT LESS THAN 2 GALS PER DAY
APPROVED SOURCES
DISTILLATION

REVERSE OSMOSIS

OTHER NAVSEA APPROVED WATER PRODUCTION TECHNOLOGY
AVOID MAKING WATER WHILE OPERATING IN:
HARBORS OR FORM POLLUTED SEAWATER

SHIPS ARE OPERATED IN CLOSE FORMATION

STRIPPING OR DISCHARGING WASTE OR BILGE WATER FORWARD OF INTAKES
SHIP WATER TREATMENT PLANTS
CAPABLE OF PRODUCING WATER FROM BACTERIOLOGICALLY CONTAMINATED SEAATER
POTABLE WATER
MUST BE ADEQUATELY DISINFECTED TO MAINTAIN REQUIRED HALOGEN RESIUAL LEVEL IN POTABLE WATER TANKS & DISTRIBUTION SYSTEM.
SHORE TO SHIP DELIVERY FROM APPROVED SOURCE
EPA APPROVED

US MILITARY APPROVED INCLUDING UNDER COGNIZANCE OF:
BRITISH
CANADIAN
AUSTRALIAN
OTHER CONUS LOCATIONS OBTAINED UNDER NEMPU
NEMPU
NAVY ENVIROMENTAL PREVENTIVE MEDICINE UNITS
EPA
ENVIROMENTAL PROTECTION AGENCY (STATE AND TERRITORY)
APPROVED SOURCES
DISTILLATION, REVERSE OSMOSIS, NAVSEA APPROVED

SHORE TO SHIP (APPROVED AND UNAPPROVED)

SHIP TO SHIP
DISTILLATION PLANTS
STEAM

WASTE HEAT

VAPOR COMPRESSION TYPE
VAPOR COMPRESSION TYPE
USES ELCETRICAL ENERGY
WHAT KIND OF MATERIAL IS PROHIBITED ON BOARD SHIP IN BERTHING?
POLYURETHANE
SINGLE PASS RO PLANTS
ADDITIONAL DISINFECTION SUCH AS BROMINATION AND CHLORINATION NEEDED
TRIPLE PASS TO PLANTS
(SUBMARINE) ADDITIONAL DISINFECTION NOT REQUIRED
SHIPBOARD WATER SYSTEM COMPONENTS
POTABLE WATER TANKS

VENTS AND OVERFLOWS

MANHOLES

WATER LEVEL MEASUREMENT

FILLING LINES

PIPING
SANITARY REQUIREMENTS
POTABLE WATER HOSE LOCKERS

POTABLE WATER HOSE
LABELING REQUIREMENTS
HOSES

VALVES FOR RECEIVING OR SUPPLYING POTABLE WATER (RISERS)

SOUNDING TUBES

POTABLE WATER HOSE LOCKERS
POTABLE WATER TRANSFER (RECEIVING)
TEST HALOGEN PRIOR TO INITIAL TRANSFER OF WATER

SUPERVISED POTABLE WATER CONNECTIONS

MDR NOTIFIED BY ENGINEERING PRIOR TO CONNECTION

HOSE NOT SUBMERGED IN HARBOR WATER
POTABLE WATER FROM DOUBTFUL SOURCE
2.0 PPM MINIMUM HALOGEN RESIDUAL (ADVISE CO)
HALOGEN RESIDUAL
(CHLORINE / BROMINE)
QUICK INDICATOR OF IMPROPERLY TREATED WATER

ABSENCE OF HALOGEN MAY INDICATE CONTAMINATION

SHIP MUST MAINTAIN 0.2 PPM FAC OR TABR AFTER INITIAL TREATMENT
BACTERIOLOGICAL TESTING
ENSURE FITNESS FOR HUMAN CONSUMPTION

TO ASSESS ADEQUACY OF DISINFECTION PROCESS
TESTING REQUIREMENTS
STANDARD METHODS FOR THE EXAMINATION OF WATER AND WASTE WATER

CHEMICAL QUALITY

TEMPERATURE / PH

SALINITY

HALOGEN RESIDUAL

MICROBIOLOGICAL QUALITY
POTABLE WATER TESTING PROCEDURES
HALOGEN

COLOR COMPARATOR TEST KIT PROCEDURE

PORTABLE SPECTROPHOMETER PROCEDURE
APPROVED METHODS
COLILERT AND COLISURE

ANY EPA APPROVED METHOD MAY BE USED
BACTERIOLOGICAL TESTING FREQUENCY
WEEKLY

ABNORMAL HALOGEN DEMAND PRESENT

SUSPICION OF CONTAMINATION

AFER REPAIRS TO POTABLE WATER SYSTEM
BACTERIOLOGICAL TESTING PROCEDURES
COLLECTION AND PREPARATION OF SAMPLE

AFTER HALOGEN SAMPLE

LABEL

100ML TAP WATER WITH SODIUM THIOSULFATE

ADD COLILERT OR COLISURE REAGENT

ICUBATE 24 HOURS @ 35 DEGREE C

EXAMINE AFTER 24 HOURS

POS AND NEG CONTROL CONDUCTED ON DAY OF TESTING

RECORD RESULTS
COLILERT TESTING
CLEAR IS NEGATIVE

YELLOW IS POSITIVE FOR TOTAL COLIFORM

FLOURECENT YELLOW (UNDER UV LIGHT) IS POSITIVE FOR FECAL COLIFORM
COLISURE TESTING
YELLOW IS NEGATIVE

MAGENTA IS POSITIVE

FLUORESCENT LIGHT BLUE IS POSITIVE FOR E.COLI
SOURCES OF CONTAMINATION
CROSS CONNECTIONS
LEAKS
IMPROPER DISPOSAL OF CHEMICALS OR LIQUIDS
MISUSE OF HOSES
EXCESSIVE STORAGE TIMES
WATER FROM CONTAMINATED RAW WATER SOURCE
INADEQUATE DISINFECTION
TRANSFERED WATER WITH ODOR AND TATSE PROBLEMS
TANKS USED FOR OTHER LIQUIDS
DETERIORATED TANKS
WATER PRODUCED WHILE STRIPPING TANS, BILGES, OR CLOSE TO OTHER SHIP
WATER DISINFECTION PROCEDURE
CHLORINE AND BROMINE

AUTOMATIC CHLORINE DISINFECTION

BROMINATOR

MANUAL CHLORINE DISINFECTION (BATCH METHOD)
APPROVED SHIPBOARD DISINFECTING METHODS
CHLORINE AND BROMINE
BROMINATOR TYPES
IN LINE (PROPORTIONING)

RECIRCULATION
IN LINE BROMINATOR
CAN DELIVER 2.0 PPM BROMINE
RECIRCULATION BROMINATOR
DESIGNED TO BOOST BROMINE RESIDUAL IN POTABLE WATER TANK

DELIVERS 0.7 PPM BROMINE TO WATER BEING RECIRCULATED
HALOGEN RESIDUALS
APPROVED SOURCE: 0.2 PPM AFTER 30 MIN

UNAPPROVED SOURCE: 2.0 PPM AFTER 30 MIN

CHLORINATED BY BATCH METHOD IF TBR OF 2.0 PPM CANNOT BE ACHIEVED.
REQUIREMENTS FOR TASTE AND WATER PROBLEMS
CHLORINATION METHOD

CHLORINATE TO 5.0 PPM FAC

DISTIBUTE AT 2.0 PPM FAC
STORING BROMINE CARTRIDGES
MUST HAVE HAZARDOUS WARNING PLATE "IAW NSTM CHAPTER 533"
WATER SANITATION BILL
POSTED CONSPICUOUSLY IN AREAS WHERE POTABLE WATER AND ASSOCIATED MATERIALS ARE PROCESSED, TREATED OR STORED
WATER SANITATION BILL CONSIST OF
RESPONSIBILITY
SOURCES
CONNECTION PROCEDURES
POTABLE WATER HOSES
STORAGE TANKS
DISINFECTION PROCEDURES
HALOGEN RESIDUAL TESTING
BACTERIOLOGICAL TESTING
TEMPERATURE, PH AND SALINITY TESTING
DISINFECTION OF TANKS AND DISTRIBUTUION SYSTEM
DISTRIBUTUION SYSTEM
REOCRDS
POTABLE WATER LOG
MDR MAINTAIN 2 YR CHRONOLOGICAL REOCORD
POTABLE WATER LOG INCLUDES
TIME AND DATE EACH WATER SAMPLE
LOCATION OF SHIP
SAMPLING SITE
SOURCE
HALOGEN RESIDUAL
BACTERIOLOGICAL TEST RESULTS
ACTION TAKEN FOR ANY DISCREPANCIES FOUND
MEDICAL DEPARTMENT RESPONSIBILITIES
CONDUCT VISUAL INSPECTIONS

INDOCTRINATION

PROVIDE ON SITE ADVISE

BE PRESENT DURING CLEAN UPS AND DISINFECTION
COLLECTION, HOLDING AND TRANSFER SYSTEM (CHT)
OPERATES IN 3 MODES:

RESTRICTED

AT SEA

IN PORT
FUNCTIONAL ELEMENTS OF CHT
COLLECTION

HOLDING

TRANFER
COLLECTION ELEMENT
SOIL DRAINS OR SEWAGE

GRAY WATER DRAINS

DIVERTER VALVES, DIRECTS WATER TO WASTE TANKS OR OVER THE SIDE
HOLDING ELEMENT
TANKS THAT RETAIN SEWAGE DURING TRANSIT OF RESTRICTED WATER FOR EVENTUAL DISPOSAL (12HR HOLDING PERIOD)
TRANSFER ELEMENT
SEWAGE PUMPS

OVERBOARD AND DECK CONNECTION DISCHARGE PIPING

ASSOCIATED DIVERTER VALVES AND CHECK VALVES
MODES
MANUAL AND AUTOMATIC
MANUAL MODE
PUMPS ARE ACTUATED INDEPENDENT OF WASTE WATER IN HOLDING TANK

DEACTIVATES AUTOMATICALLY WHEN TANKS REACH 10%
AUTOMATIC MODE
LOW LEVEL STOPS TANK AT 10% TO KEEP PUMP PRIMED

30% CAPACITY SIGNALS DUTY PUMP TO ACTIVATE

60% CAPACITY SIGNALS STANDBY PUMP

80% CAPACAITY, VISUAL AND AUDIBLE HIGH LEVEL ALARM ACTIVIATED
HEALTH AND SAFETY ALARM INSPECTION REQUIREMENTS
TANKS LARGER THAN 2,000 GALS MUST BE AERATED, CAN BECOME EXPLOSIVE.
HYDROGEN SULFIDE
ROTTEN EGG SMELL
TOXIC OR EXPLOSIVE GASES ASSOCIATED WITH CHT
HYDROGEN SULFIDE

METHANE

AMMONIA

CARBON DIOXIDE
BASIC IMMS
POLIO

TETANUS

DIPHTHERIA
REQUIRED PPE
COVERALLS

RUBBER BOOTS

RUBBER GLOVES

FACE SHIELDS

SCBA
SEWAGE SPILL CLEAN UP PROCEDURES
POTABLE WATER MUST BE SECURED, DISINFECTED, AND RECHECKED UNTIL WATER IS DEEMED SAFE
COLOR CODING REQ
SHIPS INTERIOR COLOR CODE IS GOLD
DECK DISCHARGE STATIONS MUST BE CLEARLY LABELED:
HOSE HANDLING PROCEDURES

SANITARY HEALTH PRECAUTIONS
WASTE WATER DISPOSAL PROCEDURES
OVERBOARD DISCHARGE OF UNTREATED SEWAGE IN U.S. WATERS PROHIBITED WITHIN 3 NAUTICAL MILES
CHT SYSTEMS AT SEA
SEWAGE AND GRAY WATERS, INCLUDING THOSE STORED IN HOLDING TANKS ARE DIVERTED OR DISCHARGED OVERBOARD
CHT SYSTEMS IN PORT
SEWAGE AND GRAY WATER IS COLLECTED IN HOLDING TANKS AND DISCHARGED INTO SANITARY SEWER OR SHIP WASTE OFF LOAD BARGES
SWOB
SHIP WASTE OFF LOAD BARGES
RESTRICTED WATERS
SEWAGE COLLECTED AND STORED IN HOLDING TANKS

GRAY WATER IS DISCHARGED OVERBOARD VIA DIVERTER VALVES
UNIT COMMANDER
ENSURES
ENFORCEMENT
INFORM
KNOW
ENGINEERING OFFICER
PROVIDES
CONSTRUCTUION
SELECTING
MEDICAL DEPARTMENT
ADVISES
ASSISTS
CONDUCT
TEST
INFORM ENGINEERS
CHEMICAL ANALYSIS
ACCPATABLE WATER SUPPLY SOURCES
ALL SOURCES IN THE FIELD CONSIDERED UNSAFE UNTIL EVALUATED AND APPROVED BY MDR
INFLUENCES ON WATER CHOICE
QUALITY

QUANTITY

ACCESSIBILITY
POTENTIAL WATER SOURCES
PUBLIC WATER SUPPLY

SURFACE WATER

GROUND WATER

COMMERCIAL BOTTLED WATER
PUBLIC WATER SUPPLY
EASIEST AND SAFEST SOURCE

WATER TREATED TO SOME EXTENT

UNSAFE UNTIL APPROVED FOR CONSUMPTION

EVALUATE AND TREAT TO MAKE WATER SAFE
SURFACE WATER
MORE ACCESSIBLE

QUALITY MAY BE PROBLEM

MORE CONTAMINATED

ADEQUATE QUANTITIES

RIVERS, STREAMS, LAKES, PONDS, SEAS, OCEANS

SHOULD BE SCREENED AND CAREFULLY POSITIONED
GROUND WATER
30 YARDS UPGRADIENT FROM KNOWN CONTAMINATION
COMMERCIAL BOTTLED WATER
SEALED AND PACKAGED BY COMMERCIAL INTEREST

MAY OR MAY NOT BEEN TREATED PRIOR TO PACKAGING

MUST BE TESTED
TYPICAL FIELD WATER TREATMENT PROCESS
STRAINING

CHEMICAL ADDITION

COAGULATION

SEDIMENTATION

FILTRATION
REQUIRED CHLORINE RESIDUALS
IF BETWEEN 0.2PPM AND 1PPM FAC- RECHLORINATE TO 1PPM AND DELIVER

IF LESS THAN 0.2PPM FAC- RECHLORINATE TO 2PPM AND ENSURE AT LEAST 1PPM FAC REMAIN AFTER 30 MIN
WHAT ARE THE REQUIREMENTS FOR POTABLE WATER HOSES?
APPROVED,
EXAMINED ROUTINELY,
REMOVED FROM USE WHEN CRACKS AND LEAKS,
CAPPED OR COUPLED AND STORED IN HOSE LOCKER.
NOT USED FOR ANY OTHER PURPOSE.
HOW MANY MODES ARE THERE FOR CHT SYSTEM
3
FILLING CANTEENS, PERSONAL HYDRATION SYSTEM, OR OTHER INDIVIDUAL USE CONTAINERS
0.2PPM FAC
POINT OF PRODUCT AND INITIAL DISTRIBUTION
2PPM FAC AFTER 30 MIN CONTACT TIME.
DISINFECTING NATURAL SURFACE WATER OR WELL WATER UNDER DIRECT INFLUENCEOF SURFACE WATER FOR DRINKING, NO OTHER TREATMENT AVAILABLE.
5PPM FAC AFTER 30 MIN CONTACT TIME
IODINE TABLETS
2 IODINE TABLETS TO 1 QUART CANTEEN
FIVE GALLON CANS (WATER JUGS)
40 IODINE TABLETS IN CANTEEN CUP

WAIT 5 MINUTES THEN SHAKE

WAIT ADDITIONAL 25 MIN TO DRINK
PERSONAL HYDRATION SYSTEM
4 IODINE TABS TO 70-72 OZ WATER RESERVOIR

6 TABS FOR 100-102 OZ RESERVOIR

DOUBLE IODINE AMOUNT FOR CLOUDY WATER
MINIMUM USAGE REQUIREMENTS
NEW SHIP CONSTRUCTION, 50 GALS PER MAN PER DAY
THE WDWMS CONSIST OF HOW MANY MODULES?
3
HOW DO YOU TEST FOR CHT LEAKS?
PAPER TOWEL TEST
IS HOT BUNKING ALLOWED
NO
SHIPS COMPANY
ALL PERSONNEL ASSIGNED TO A SHIP
TRANSIENTS
PERSONNEL EMBARKED FOR SHORT PERIOD OF TIME
WHAT TO USE TO CLEAN BABRBERSHOP EQUIPMENT?
EPA APPROVED DISINFECTING SPRAY AND SOAP AND WATER.
MEDICAL REQUIREMENTS FOR BARBERSHOP WORKERS
FREE OF COMMUNICABLE DISEASES
MEDICAL REQUIREMENTS FOR LAUNDRY WORKERS
PRE EMPLOYMENT

PERIODICALLY
LAUNDRY RECEIVED IN?
IMPERVIOUS DOUBLE SEALED BAG
WHAT HAPPENS WHEN CHT WORKERS DO NOT WASH HANDS?
CROSS CONTAMINATION
CONCERNS FOR PERSONNEL WORKING WITH CHT
EXSPOSURE TO TOXIC GASES

KEEP IMMUNIZATIONS CURRENT
STORAGE REQUIREMENTS FOR HTH (CALCIUM HYPOCHLORITE) 65%-70% AVAILABLE CHLORINE
6 OZ BOTTLES

METAL LOCKED BOX MOUNTED ON BULKHEAD

THREE 1/4 IN HOLE TO ALLOW VENTILATION

NO MORE THAN SEVEN DAY SUPPLY
BROMINATORS
IN-LINE (PROPORTIONING)

RECIRCULATION
IN-LINE BROMINATOR
PRESET TO DELIVER 0.7PPM BROMINE TO WATER DURING NORMAL OPERATING PROCEDURES

CAN DELIVER 2.0PPM WHEN NEEDED
RECIRCULATION BROMINATOR
DELIVERS 0.7 BROMINE TO WATER BEING RECIRCULATED

DESIGNED TO BOOST BROMINE RESIDUAL IN POTABLE WATER TANKS
WHAT IS THE ADVANTAGE OF USING A SPECTROPHOTOMETER?
ACCURACY IS (+) OR (-) 2 PERECNT
COLOR CAOMPARATOR KIT
ACCURACY IS (+) OR (-) 10 PERCENT
TBR TESTING PROCEDURES, HOW MANY ARE THERE? HOW MANY ON DDG?
6, 4 TANKS, 1 ICE MACHINE, 1 SCUTTLE BUTT.
WHO IS RESPONSIBLE FOR CHECKING THE LEVEL OF HALOGEN AFTER 30 MINUTES?
ENGINEERING DEPARTMENT
WHAT IS USED TO ASSESS ADEQUACY OF THE POTABLE WATER DISINFECTION PROCESS?
BACTERIOLOGICAL TESTING
WHY DO WE DO HALOGEN TESTING?
A QUICK INDICATION OF WATER THAT MAY HAVE BEEN IMPROPERLY TREATED OR HANDLED

ABSENCE OF HALOGEN IN THE SHIPS POTABLE WATER MAY INDICATE CONTAMINTATION.
WHY DO WE DO BACTERIOLOGICAL TESTING?
ENSURE FITNESS FOR HUMAN CONSUMPTION

TO ASSESS ADEQUACY OF DISINFECTION PROCESS
ADD ADDITIONAL DPD #1 TABLET IF:
THE COLOR IS DEEPER THAN 5.0PPM CHLORINE OR 11.0PPM BROMINE COLOR STANDARDS