• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/108

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

108 Cards in this Set

  • Front
  • Back
A RAISED FRAME (AROUND A HATCHWAY IN THE DECK) TO KEEP OUT WATER
COAMING
THE TOTAL PROCESS THE DISTILLING PLANT FORMS, INCLUDING EVAPORATION AND CONDENSATION
DISTILLATION
CHLORINE AVAILABLE (AFTER DEMAND IS MET) IN THE FORMS OF HYPOCHLOROUS ACID AND HYPOCHLORITE IONS
FREE AVAILABLE CHLORINE (FAC)
A UNIT OF LENGTH. ONE MILLIONTH OF A METER
MICRON
A TX DEVICE APPLIED TO A SINGLE TAP USED FOR THE PURPOSE OF REDUCING CONTAMINANTS IN DRINKING WATER AT THE TAP
POINT OF USE (POU)
H20 THAT IS CONSUMABLE FOR HUMAN CONSUMPTION, BATHING, LAUNDRY, PERSONAL HYGIENE
POTABLE WATER
THE REVERSE OF THE NATURAL OSMOSIS ACHIEVED BY EXTERNAL APPLICATION OF SUFFICIENT REVERSE PRESSURE TO CAUSE THE SOLVENT TO FLOW IN ITS UNNATURAL DIRECTION.
REVERSE OSMOSIS (RO)
TEST USED TO DETECT TOTAL COLIFORM AND E-COLI IN THE POTABLE WATER
COLILERT / COLISURE
GROUP OF CLOSELY RELATED, MOSTLY HARMLESS BACTERIA LIVING IN SOIL, WATER, AND GUTS OF ANIMALS. CAN INDICATE THE GENERAL QUALITY OF H20 AND TELLS WETHER THERE IS FECAL CONTAMINANTS
TOTAL COLIFORM
FECAL COLIFORM BACTERIA FOUND IN THE INTESTINES OF ANIMALS AND HUMANS.
E. COLI (ESCHERICHIA COLI)
RESPONSIBLE FOR SHIPBOARD POTABLE WATER SYSTEMS INCLUDING TX FACILITIES AND PROCESSES. DESIGN, CONSTRUCTION, MAINTENANCE
NAVSEASYSCOM
RESPONSIBLE FOR PROMULGATING INSTRUCTIONS FOR SHIP-TO-SHORE H20 CONNECTIONS
NAVAL FACILITIES ENGINEERING COMMAND (NAVFACENGCOM)
ESTABLISH THE SHIPBOARD REQS FOR MED SURVEILLANCE OF POTABLE H20
CHIEF, BUMED
ISSUING THE NECESSARY IMPLEMENTING DIRECTIVES TO ENSURE ADEQUATE H20 SANITATION STANDARDS IN EACH SHIP WITHING THE COMMAND
AREA, FLEET AND SUBORDINATE COMMANDERS
PROMULGATING A H20 SANITATION BILL TO ENSURE PROCEDURES FOR RECEIPT, TRANSFER, TX, STORAGE, DISTRIBUTION, AND SURVEILLANCE ARE PROVIDED
COMMANDING OFFICERS
RESPONSIBLE TO CO FOR IMPLEMENTING THE REQS OF NAVSEASYSCOM
ENGINEERING DEPARTMENT
RESPONSIBLE FOR CONDUCTING A MEDICAL SURVEILLANCE PRGM OF POTABLE H20
MEDICAL DEPARTMENT REPRESENTATIVE
HOW MUCH WATER ARE NEW SHIP CONSTRUCTION AT MINIMUM TO USE? WHAT ABOUT DURING "WATER HOURS"?
50 GALLONS PER MAN PER DAY, NOT LESS THAN 2 GALLONS PER MAN PER DAY
WHAT IS THE SIZE OF COAMING AROUND A MANHOLE?
1/2" CURB OR COAMING
WHAT IS THE PROCESS FOR CLEANING A STEEL TAPE FOR WATER MEASUREMENT?
100PPM FAC FOR 2 MINUTES
WHAT COLOR CODE IS USED FOR FILLING CONNECTIONS?
DARK BLUE
HOW HIGH OFF OF THE DECK ARE FILLING CONNECTIONS (HOSE VALVES, RISERS)?
18 INCHES OFF THE DECK
WHAT TEMPERATURE IS POTABLE HOT WATER SUPPOSED TO BE AT THE TAP?
120*F
PORTABLE WATER HOSE STORAGE REQS?
VERMIN PROOF, LOCKED, 18 INCHES OFF THE DECK, INSTRUCTIONS FOR DISINFECTION POSTED IN STORAGE
POTABLE WATER HOSE REQS AND LABELING?
EXAMINED ROUTINELY, REMOVED WHEN CRACKED OR LEAKS ---"POTABLE WATER ONLY" IN 1 INCH LETTERS EVERY 10 FEET
IRT LABELING WHAT IS ON THE VALVES FOR RECEIVING OR SUPPLYING POTABLE H20 (RISERS)?
WARNING PLATE "POTABLE WATER ONLY" IN 1/4 INCH HIGH LETTERS
IRT LABELING WHAT IS LABELED FOR A SOUNDING TUBE?
ID PLATE, SOUNDING CAP WILL BE DARK BLUE
WHEN RECEIVING WATER FROM AN APPROVED SOURCE WHAT MUST THE RESIDUAL HALOGEN BE?
0.2 PPM
WATER FROM DOUBTFUL QUALITY SOURCES HAS A MINIMAL HALOGEN RESIDUAL REQUIREMENT OF?
2.0 PPM
CHLORIDE SHALL NOT EXCEED_____ IN REGARDS TO SALINITY FOR POTABLE WATER TESTING REQUIREMENTS?
0.065 EQUIVALENT PER MILLION (EPM) OR 2.3 PPM
IRT FREQUENCY OF MONITORING WHEN THERE ARE 400 PERSONNEL ABOARD HOW MANY SAMPLES NEED TO BE TAKEN?
NO LESS THAN 4
IRT FREQUENCY OF MONITORING WHEN THERE ARE 400-800 PERSONNEL ABOARD HOW MANY SAMPLES NEED TO BE TAKEN?
8 SAMPLES
IRT FREQUENCY OF MONITORING WHEN THERE ARE MORE THAN 800 PERSONNEL ABOARD HOW MANY SAMPLES NEED TO BE TAKEN?
12 SAMPLES
WHEN TAKING SAMPLES, _____ OF SHIPS POTABLE MACHINES AND WATER TANKS WILL BE INCLUDED?
1/4
HOW OFTEN DO WE TEST EMERGENCY POTABLE WATER TANKS?
MONTHLY
IRT REPEAT MONITORING HOW MANY REPEAT SAMPLES WILL BE TAKEN AND WHERE FROM?
3 SAMPLES, ONE FROM THE ORIGINAL SOURCE, ONE UPSTREAM, ONE DOWNSTREAM(NO MORE THAN 5 SERVICE CONNECTIONS) AND ALL WILL BE TAKEN WITHIN 24 HOURS OF POSITIVE SAMPLE
IRT POTABLE WATER TESTING OF HALOGEN, WHAT DOES DPD #1 TEST FOR?
FAC OR TBR
IRT POTABLE WATER TESTING OF HALOGEN, WHAT DOES DPD #4 TEST FOR?
CHLORAMINES (TOTAL CHLORINE) RESIDUAL
IRT POTABLE WATER TESTING HOW ACCURATE IS THE COLOR COMPARATOR?
PLUS OR MINUS 10%
IRT POTABLE WATER TESTING HOW ACCURATE IS THE PORTABLE SPECTROPHOTOMETER?
PLUS OR MINUS 2%
HOW MUCH WATER IS USED FOR THE TEST TUBE OF THE COLOR COMPARATOR TEST KIT?
10ML
HOW MUCH WATER IS COLLECTED AND WHAT CHEMICAL IS CONTAINED DURING BACTERIOLOGICAL TESTING?
100ML IN SAMPLE BOTTLE OR BAG CONTAINING SODIUM THIOSULFATE
HOW LONG DO YOU INCUBATE SAMPLES AND AT WHAT TEMP IRT BACTERIOLOGICAL TESTING?
24 HOURS AT 35*C
YELLOW SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLILERT?
POSITIVE FOR TOTAL COLIFORM
FLUORESCENT YELLOW SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLILERT?
POSITIVE FOR FECAL COLIFORM
CLEAR SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLILERT?
NEGATIVE
YELLOW SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLISURE?
NEGATIVE
MAGENTA SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLISURE?
POSITIVE FOR TOTAL COLIFORM
FLUORESCENT LIGHT BLUE SIGNIFIES WHAT AFTER 24 HOURS, UNDER A UV LAMP IRT COLISURE?
POSITIVE FOR E. COLI
WHAT ARE THE APPROVED METHODS FOR DISINFECTING SHIPBOARD POTABLE WATER?
CHLORINE AND BROMINE
HOW IS BROMINE DISPENSED?
A RESIGN IMPREGNATED CARTRIDGE
HOW MANY BROMINATORS ARE THERE AND WHAT ARE THEY?
2, IN-LINE (PROPORTIONING) BROMINATOR, AND RECIRCULATION BROMINATOR
HOW DOES THE IN-LINE BROMINATOR WORK?
PRESET TO DELIVER 0.7 PPM BROMINE TO H20 DURING NORMAL OPERATING PROCEDURES, CAN DELIVER UP TO 2.0 PPM WHEN NECESSARY, REQUIRED FOR EACH H2O PLANT
HOW DOES THE RECIRCULATION BROMINATOR WORK?
DESIGNED TO BOOST BROMINE RESIDUAL IN POTABLE H2O TANK, DRAWS H2O FROM THE TANK, INJECTS BROMINE, AND RETURNS WATER TO SAME TANK. DELIVERS 0.7 PPM BROMINE TO H2O BEING RECIRCULATED
WHAT IS THE CHLORINE DOSAGE RULE OF THUMB?
ONE OUNCE OF HTH (CALCIUM HYPOCHLORITE) PER 5,000 GALLONS OF H2O EQUALS 1.0 PPM FAC
METHOD ONE DISINFECTION?
1. FILL TANK TO OVER FLOW
2. ADD CHLORINE TO ACHIEVE 10PPM FAC, HOLD SOLUTION FOR 24 HOURS
3. DRAIN
4. REFILL WITH REQUIRED HALOGEN
5. IF NEW TEST COMES NEGATIVE, USE THE H2O
METHOD TWO DISINFECTION?
1. SPRAY/APPLY DIRECTLY 200PPM FAC TO ALL TANK SURFACES.
2. FLUSH INLET/OUTLET PIPES WITH 10PPM FAC
3. SURFACES STAY IN CONTACT W/ SOLUTION FOR 30 MIINS
4. REFILL IF NEGATIVE USE H2O
METHOD THREE DISINFECTION?
1. FILL 5% OF TANK VOLUME WITH 50PPM FAC SOLUTION
2. HOLD SOLUTION FOR 6 HRS
3. ADD POTABLE H2O TO SOLUTION TO FILL THE TANK, HOLD FOR 24 HRS
4. DRAIN
5. REFILL, IF NEGATIVE USE H2O
IRT CONTROLLING TASTE AND ODOR, WHAT ARE THE MEASUREMENTS WHEN USING THE CHLORINATION METHOD?
CHLORINATE TO 5.0 PPM FAC
DISTRIBUTE AT 2.0 PPM FAC
WHEN STORING HTH 65%-70%, WHAT RECEPTACLE IS USED?
6 OUNCE BOTTLES
WHEN STORING HTH 65%-70%, WHAT CONTAINER IS USED?
METAL BOX SUCH AS FIRST AID LOCKER, WITH 1/4 INCH HOLES DRILLED IN THE BOTTOM TO ALLOW THE RELEASE OF CHLORINE GAS
WHERE CAN A HTH BOX NOT BE STORED?
1. MACHINERY SPACE
2. FLAMMABLE LIQUIDS ROOM
3. BERTHING SPACE
4. PAINT STOREROOM
5. OIL AND H2O TEST LAB AREAS
NO MORE THAN _______ SUPPLY SHALL BE MAINTAINED IN READY USE STOCK AT ANY TIME?
SEVEN DAY
MAXIMUM TEMP OF ______ CAN NOT BE EXCEEDED IN THE STORAGE OF HTH?
100*F AND NOT SUBJECT TO CONDENSATION OR WATER ACCUMULATION
WHTA IS THE MAX AMOUNT OF BOTTLES STORED IN ANY INDIVIDUAL LOCKER OR BIN?
48 SIX OUNCE
HOW DO YOU LABEL LOCKERS, BINS, AND ENCLOSURES CONTAINING HTH?
"HAZARDOUS MATERIAL, CALCIUM HYPOCHLORITE" RED LETTERS WITH A WHITE BACKGROUND
IRT STORING BROMINE CARTRIDGES, HOW ARE THE LOCKERS LABELED?
WITH A HAZARDOUS WARNING PLATE IAW NSTM CHAPTER 533
WHAT IS THE SHELF LIFE OF A BROMINE CARTRIDGE?
2 YEARS FROM MANUFACTURE DATE
HOW LONG DOES THE MDR MAINTAIN COPIES OF THE POTABLE WATER SURVEILLANCE?
2 YEAR CHRONOLOGICAL RECORD
WHAT IS CONTAINED IN THE WATER LOG?
TIME AND DATE, LOCATION OF SHIP, SAMPLING SITE, SOURCE, HALOGEN RESIDUAL, BACTERIOLOGICAL TEST RESULT INCLUDING +/- CONTROLS, ACTION TAKEN FOR DISCREPANCIES FOUND
HOW MANY MODES DOES THE COLLECTION HOLDING AND TRANSFER SYSTEM (CHT) OPERATE IN? WHAT HAPPENS IN THEM?
RESTRICTED WATERS - GRAY WATER
AT SEA - GRAY AND BLACK WATER
IN PORT - ONLY TO THE BARGE
WHAT ARE THE FUNCTIONAL ELEMENTS OF THE CHT SYSTEM?
1. COLLECTION ELEMENT
2. HOLDING ELEMENT
12 HOUR HOLDING PERIOD
3. TRANSFER ELEMENT
IRT TRANSFER ELEMENT HOW MANY PUMPS ARE IN EACH TANK?
2 PUMPS PER TANK
IRT TRANSFER ELEMENT WHEN IN MANUAL MODE, WHEN DOES THE PUMP DEACTIVATE?
WHEN THE TANK REACHES 10% TANK VOLUME TO MAINTAIN PUMP SUCTION
IRT TRANSFER ELEMENT WHEN IN AUTOMATIC MODE, DESCRIBE THE DIFFERENT LEVELS OF THE PUMP AND WHAT HAPPENS?
1. LOW LEVEL STOPS PUMP AT 10% TO KEEP THEM PRIMED
2. 30% SIGNALS DUTY PUMP TO ACTIVATE
3. 60% SIGNALS STANDBY PUMP TO ACTIVATE
4. 80% A VISUAL AND AUDIBLE HIGH LEVEL ALARM IS ACTIVATED
IRT HEALTH AND SAFETY INSPECTION REQS, WHEN ARE UNTREATED SEWAGE TANKS AERATED?
2,000 GALLONS OTHERWISE IT CAN BECOME EXPLOSIVE
IRT HEALTH AND SAFETY INSPECTION REQS, HOW MANY EEBDs ARE IN A PUMP ROOM?
TWO
IRT HEALTH AND SAFETY INSPECTION REQS, WHERE IS THE EXHAUST VENTILATION IN A PUMP ROOM?
WITHIN 9 INCHES OF THE DECK
IRT HEALTH HAZARDS ASSOCIATED WITH CHT SYSTEMS, WHAT ARE THE BASIC IMMUNIZATIONS PERSONNEL IN CONTACT WITH WASTE WATER MUST HAVE?
1. POLIO
2, TETANUS
3. DIPTHERIA
WHERE CAN YOU FIND GUIDANCE ON SEWAGE SPILL CLEANUP PROCEDURES?
NAVSHIPS TECHNICAL MANUAL (NSTM) CHAPTER 593 "POLLUTION CONTROL"
IRT COLOR CODING AND LABELING REQS FOR CHT SYSTEMS, WHAT COLOR IS THE SHIP's INTERIOR COLOR CODE?
GOLD ON VALVE HANDLES AND OPERATING LEVERS
WHEN IS IT AUTHORIZED TO DISCHARGE UNTREATED SEWAGE WITHIN US WATERS AND TERRITORIAL SEAS?
ONCE OUT 3 NAUTICAL MILES FROM THE SHORE
WHAT MAY YOU HAVE FOR PERSONAL BERTHING?
1 PILLOW, MATTRESS, BUNK LIGHT, AND PRIVACY CURTAIN
HOW DO SAILORS SLEEP IN THE BERTHING
HEAD, TOE, HEAD, TOE, ETC
WHAT ARE THE DIFFERENT DISTILLATION PLANTS?
STEAM, VAPOR, AND WASTE DISTILLATION PLANTS
WHAT ARE THE DIFFERENT WATER SOURCES?
1. DISTILLATION, REVERSE OSMOSIS, OTHER NAVSEA APPROVED PRODUCTION TECHNOLOGY
2. SHORE - SHIP APPROVED
3. SHIP - SHORE UNAPPROVED
4. SHIP TO SHIP
WHAT ARE THE SHORE TO SHIP APPROVED WATER SOURCES?
1. EPA APPROVED PUBLIC WATER SYSTEM
BRITISH ROYAL NAVY, CANADIAN FORCES, ROYAL AUSTRALIAN NAVY, AREAS OF NEPMU RESPONSIBILITY
HOW MANY IODINE TABLETS ARE USED FOR CANTEEN DISINFECTION WATER?
4 TABLETS FOR 2 QUART CANTEEN, WAIT 25 MINUTES BEFORE CONSUMPTION
HOW MANY IODINE TABLETS ARE USED FOR WATER JUG DISINFECTION WATER?
40 IODINE TABLETS 5 MINUTES THEN GET THE THREADS THEN 25 MINUTES BEFORE CONSUMPTION
HOW MANY IODINE TABLETS ARE USED FOR PERSONAL HYDRATION SYSTEM DISINFECTION WATER?
4 TABLETS FOR 70-72 OUNCES, 6 TABLETS FOR 100-102 OUNCES WAIT 30 MINS BEFORE CONSUMPTION, IF CLOUDY OR DISCOLORED, DOUBLE TO TABLETS
REQUIRED RESIDUALS FOR THE FIELD?
2PPM FAC AFTER 30 MINS CONTACT FOR INITIAL DISTRIBUTION, 1PPM DELIVERY TO SECONDARY STORAGE (ie WATER BUFFALO)
WATER DISTRIBUTION AND WASTE MANAGEMENT SYSTEM (WDWMS) HAS HOW MANY MODULES?
3- WATER DISTRIBUTION SET
HOSPITALS
DEPLOYABLE MEDICAL SYSTEM
REQS FOR BOTTLED WATER?
1. WATER SEALED IN BOTTLES, PACKAGES OR OTHER CONTAINERS BY COMMERCIAL INTEREST
2. MUST BE TESTED AND DETERMINED POTABLE
3. MAY OR MAY NOT HAVE BEEN TREATED PRIOR TO BOTTLING
4. NO RESIDUAL REQS
WHAT IS TRANSIENT?
PERS EBARKED FOR SHORT PERIOD OF TIME NOT CONTRIBUTING TO HOST SHIP OPS CAPABILITY
WHAT IS HOT BUNKING?
2 PERS ASSIGNED TO ONE BERTH
WHAT IS SURGE?
PERS EMBARKED FOR SHORT PERIOD OF TIME FOR SPEC OPS OR EXERCISE
WHAT IS SHIPS COMPANY?
PERMANENT PERSONNEL
WHAT IS ACCOMODATIONS?
PERS SUPPORTED BY A GIVEN SHIP IRT HABITABILITY SPACES, SYSTEMS, FIXTURES AND EQUIP
HOW MANYY BARBERSHOPS DO YOU HAVE?
LESS THAN 100 ACCOM. = PORTABLE BARBER
101-300 ACCOM. = BARBERSHOP WITH ONE CHAIR
OVER 300 ACCOM. A BARBERSHOPR FOR EACH 300 INCREMENT
WHAT ARE THE MEDICAL REQS FOR THE BARBERS?
MEDICALLY SCREENED FOUND FREE OF COMMUNICABLE DISEASES,
COMPREHENSIVE TO DETECT DISEASE BASED ON LOCALITY, ANNUAL NOT NECESSARY UNLESS DEEMED BY MDR
WHAT DO BARBERS USE TO CLEAN EQUIPMENT?
WASHED WITH SOAP AND WATER, DISINFECTED USING AN EPA REGISTERED DISINFECTANT
WHEN ARE BARBERS NOT ALLOWED TO WORK ON A MEMBER?
INFLAMED OR INFECTIOUS CONDITIONS OF SCALP, FACE, AND NECK WITRHOUT A NOT FROM THE MEDICAL OFFICER
WHAT DOES LAUNDRY HAVE TO BE RECEIVED IN?
IMPERVIOUS DOUBLE SEALED BAGS
MEDICAL REQS FOR LAUNDRY WORKERS?
PRE AND PERIODIC EXAMINATIONS FOR MEMBERS EXPOSED TO DRY CLEANING SOLVENTS
IRT CHT WHAT IS SIGNIFICANT ABOUT HANDS?
NO HAND TO MOUTH CONTACT WHEN IN DIRECT SOURCE OF CONTAMINATION
WHAT TEST CAN BE USED TO DETECT LEAKS IN CHT SYSTEM?
PAPER TOWEL TEST
WHAT IS THE PURPOSE OF BACTERIOLOGICAL TESTING?
ENSURE FITNESS FOR HUMAN CONSUMPTION AND TO ASSESS ADEQUACY OF DISINFECTION PROCESS
WHAT ARE THE REQS FOR VENTS AND OVERFLOWS?
FOR REDUCING ACCIDENTAL CONTAMINATION, 18 GAUGE OR FINER NON CORROSIVE MESH, FOOD SERVICE SPACES, MEDICAL SPACES, TOILETS, ELECTRICAL ROOMS AND EXTERIOR