- Front
- Back
Major consideration for spotting apparatus for pumping to the FDC. (SOP)
|
"Safety of the driver/operator
|
|
Aerial Apparatus 1st pg. 148"
|
6% - 14%
|
|
Aerial Apparatus 1st pg. 152"
|
60 degree - outside. Never more than 90 degrees
|
|
If a 2 1/2 or 3 inch hose is supplying a pumper off of a hydrant it should be no longer that _____ feet.
|
300 feet
|
|
NFPA 1901 requires tenders to discharge at least 90% of tank volume at an average rate of _____.
|
1000 gpm
|
|
What is the basic goal of a multi-tank operation?
|
To keep the last tank in the in the chain full at all times.
|
|
What size tanks do the most efficient tenders for water shuttles have?
|
2,500 gallons
|
|
What is the minimum rating for the tip load of an aerial ladder?
|
250 lbs.
|
|
What is the minimum staging distance from a bomb incident?
|
"300 feet
|
|
NFPA 1901 Requires the parking brake to hold the apparatus in place on grades up to _____%?
|
20%
|
|
Should wheels on a parked brush rig be chalked at a fire?
|
Yes, especially rigs with hydraulic brakes.
|
|
Info Guide: Pump Ops Standards 1/11"
|
"1.monitor apparatus for problems
|
|
Brush rigs should not be operated forwards on slopes exceeding _____% or sideways on slopes exceeding _____% grade.
|
40% forward and 20% sideways.
|
|
What is the minimum dip tank depth for bucket operations?
|
2 feet
|
|
What is the maximum flame length height for direct attack?
|
4 feet
|
|
5 situations where the posted speed limit may not be exceeded:
|
"1.intersections
|
|
What is the minimum water that should be left in the tank for crew protection for wild land operations?
|
100 Gallons
|
|
On vehicle fires what is the minimum distance from the vehicle to position the apparatus?
|
100 feet from burning car
|
|
SOP 214.09 6/10"
|
100'
|
|
SOP 214.09 6/10"
|
500' - Shut off heavy equipment except dewatering ops
|
|
What does electronic governor do?
|
"1. When operating above 50 PSI it maintains pressure
|
|
How far should should the tip of the aerial extend past the roof edge for rescue?
|
6 feet
|
|
What is the minimum distance to keep aerials away from overhead power lines?
|
10 feet
|
|
SOP 202.01 6/97"
|
"1) Search, rescue, and treatment
|
|
SOP 202.01 6/97"
|
"1) Search, Rescue, Extrication, and Treatment
|
|
202.01 6/97"
|
"1) Search, Rescue, Treatment
|
|
Maximum speed limit a water tender may travel responding to an emergency.
|
Posted speed limit only
|
|
What is the friction loss for 100 feet of 5" flowing 500, 1000, and 1500 GPM?
|
"500 - 2 psi/100
|
|
What is the aerial apparatus outside/inside rule?
|
Building over 5 stories high, truck parks inside engine. Less than 5 stories, truck parks outside of engine.
|
|
What distance should vehicle be from a dip tank?
|
50 feet
|
|
Aerial Apparatus 1st pg. 116"
|
Between 70 and 80 degrees
|
|
Most hydraulic pumps cannot deliver full power to tools when hoses exceed _____ feet in length?
|
100 feet
|
|
What speed should engines be set to idle at for extended periods of time?
|
900 - 1,100 RPM
|
|
Aerial Apparatus 1st pg. 188"
|
"1) Most severely threatened
|
|
Principles of pressure:
|
"1) Pressure is perpindicular to an surface on which it acts
|
|
Apply Class A foam to structures ___ minutes before fire arrival.
|
15
|
|
Wet line width in wildland/urban interface
|
"2 1/2 X expected flame height
|
|
Hose placement for structural protection on a wildland fire (3):
|
"-one hose around each side of building
|
|
What hose should be available for apparatus protection during a wild land fire?
|
A short length of charged hose on top of hose bed or secured to side/rear
|
|
What are the BFD hose test pressures for: 1 3/4, 2 1/2...1" grass line...5" and High Pressure 5"?
|
"1 3/4 and 2 1/2 - 400 PSI
|
|
3 points"
|
"1.Used when many units dispatched
|
|
What is a wear ring on a pump?
|
(also Clearance rings) in the pump casing maintain the desired spacing between hub of impeller and casing
|
|
3 ways foam extinguishes and/or prevents fire
|
"1. separating: barrier b/w fuel and fire
|
|
SOP 206.03 6/97"
|
"Spot for aerial master stream (should fire go defensive)
|
|
(3 points)"
|
"1. used when single pump unable to supply adequate VOLUME
|
|
What is the pump's rated capacity at a draft of 10' and 20'?
|
"10' = 100%
|
|
5 factors in determining fireline width
|
"1.fuel
|
|
(2) NFPA 1906 requirements for wildland pumpers (relating to clearance)
|
"1. 20deg minimum angle of departure and approach
|
|
SOP 202.01"
|
To provide for rapid, safe, and efficient completion of assignments and tasks.
|
|
SOP 210.01 5/97"
|
"1.prevent loss of life
|
|
Very Little Changes At Pie Hole"
|
"1.vehicles 50-100' away
|
|
SOP 202.2 6/97"
|
"1.Safety
|
|
To Find Value Dump Assumptions"
|
"1.topography
|
|
SOP 202.2"
|
"1.horizontal
|
|
When setting up an aerial for rescue, what is the main objective of the placement?
|
To reach as many victims or points of egress as possible with minimum number of movements
|
|
HELO SOP"
|
"1.100' diameter circle and width of approach/departure paths
|
|
ARFF"
|
"-point at displaced threshold line
|
|
ARFF 4th pg. 20"
|
"Used to mark obstructions like structures, parked aircraft, construction areas.
|
|
IFTSA ARFF p. 20"
|
"White: runway identification numbers/letters, landing zone bars, striping
|
|
(aerial)"
|
"5 or 6%
|
|
High Rise SOP 206.10 9/09"
|
"1st Engine - Panel, announce location of problem, proceed to affected area and form fire attack group with 2nd engine and 1st truck.
|
|
PRICIER POET"
|
"1. check valves and caps
|
|
While drafting your intake indicates >22" Hg. What can you do or check to solve/identify this problem?
|
"1. Decrease lift
|
|
7 causes of friction loss in hose:
|
"1. lining in hose
|
|
Level I staging
|
#NAME?
|
|
When driving through smoke with limited visibility (4)
|
"-intermittently sound horn/siren
|
|
(2) times to use spotters when driving brush rigs
|
"1.unburned fuels higher than bumper or running boards
|
|
206.03 6/97"
|
"1. S.O.P
|
|
IFSTA Wildland 4th pg. 211"
|
"-work permiter
|
|
IFSTA Wildland 4th pg. 213"
|
"-control line along natural firebreaks, from a distance
|
|
SOP 206.1 9/8/09"
|
"1st - 2X 50' 2 1/2 w/nozzle...2 SCBA bottles...standpipe kit
|
|
353.25 10/09"
|
"BOI200408
|
|
353.35 10/09"
|
"1"" - 300' on reel and up to 300' more in backpacks and rolls. 400' max in rolls if there is no 1"" on reel.
|
|
NEWSR"
|
"1) Never trust the traffic
|
|
BFD training guide - roadways"
|
"25 - 65 feet (ratio 2.6)
|
|
BFD training guide - roadways"
|
1/4 mile before accident
|
|
The roadway safety checklist has 8 points to help you be as safe as possible in traffic. What are they?
|
"1) Limit exposure
|
|
BFD Information guide, Apparatus Backing"
|
"1) Follow spotter's signals explicitly
|
|
ARFF 4th pg. 20"
|
Taxiway (double line indicates edges of taxiway)
|
|
sign for a controlled access point
|
"solid red hold line
|
|
Atmospheric pressure in Boise is _____ PSI and _____" of Hg. (2842' elevation)
|
"13.3 PSI atmospheric in Boise x 2.04"" = 27.33"" Hg
|
|
ARFF 4th pg. 19"
|
"Sides of runways, 200' apart
|
|
ARFF 4th pg. 19"
|
Sides of taxiways, 100' apart
|
|
CHAMP KEN"
|
"1. eductor not matched to nozzle flow
|
|
D/O 2nd pg. 45"
|
"5 mph = 20'
|
|
Engine compartment inspection
|
"1.oil.....................................12.belts
|
|
If an issue with a vehicle arises in which continued use might cause further damage you should:
|
"Take rig out of service
|
|
BFD info guide 1/11"
|
"Unit designator
|
|
Four causes of no prime
|
"1. priming fluid low
|
|
SOP208.04"
|
"1.larger volume of water needed
|
|
SOP208.04"
|
"1.position to assist rescue, support confinement, protect exposure
|
|
SOP206.10"
|
"1. two sets irons
|
|
SOP 206.03 6/97"
|
"1.water supply
|
|
SOP 206.03 6/97"
|
"1. avoid parking under Power lines
|
|
SOP204.11"
|
"1.Everyone return to Ch.5
|
|
SOP204.09"
|
"1.prevent/control fire
|
|
Info Guide: Pump Ops Standards 1/11"
|
"1.backup line
|
|
Info Guide: Pump Ops Standards 1/11"
|
"1.fire or smoke intensifies
|
|
Info Guide: Pump Ops Standards 1/11"
|
"1.mode of operation
|
|
People Sometimes Pick Partners WIthout A Shot"
|
"1) Position off roadway to avoid blocking street
|
|
FOTU"
|
"1) Flow through booster line in a safe direction.
|
|
How many gallons of water does a Boise Fire Pumper carry, a Whitley, A North Ada, a BFD tender?
|
"500 gallons for BFD exception is old engine 12 - 750 gallons
|
|
211.02 1/08"
|
"Vehicle identification
|
|
Structural rigs are effective on wildland fires by being an anchor for:
|
Progressive hose lays
|
|
Aerial Apparatus 1st pg. 187"
|
"Rescue
|
|
Aerial Apparatus 1st pg. 208"
|
"75 degree elevation
|
|
Max wind speeds for full operation of aerials
|
35-40 mph
|
|
how to position turntable when aerial must operate off an incline (to reduce torsion/twisting)
|
downhill from point of operation
|
|
AAp.123"
|
25'
|
|
On tank fires, always position aerial outside of ____ ____.
|
dike walls
|
|
Which jacks are lowered first when aerial is positioned on uneven ground?
|
High side
|
|
aerial device should not be extended or retracted over the side of a vehicle when it is parked on a _________ grade, why?
|
Longitudinal, creates twisting force
|
|
How far above objective should aerial device be positioned to allow for settling from the weight of firefighters?
|
4-6"
|
|
7 signs of trouble aerial driver must be on lookout for
|
"1. leaking fuel
|
|
how should aerial be positioned in relation to victim to reduce twisting stress on device?
|
perpendicular
|
|
75-80-80 rule for elevated stream off of aerial
|
"75deg elevation
|
|
4 methods of proportioning foam
|
"1. induction
|
|
4 foam application methods
|
"Direct: application of Class A to burning material
|
|
Foam Generator"
|
"Piercing nozzle - 100 psi, 150 gpm
|