  • Front
  • Back
Which stages is bleed air supplied from?
Bleed air is supplied from the 5th and 9th satge. When 5th stage bleed air supply is insuffcient the high stage valve opens to maintain adequate bleed air pressure.
How how engine BLEED AIR valves activated?
The valves activated by DC power and operated pnumatically.
What does BLEED TRIP OFF light indicate?
The BLEED TRIP OFF light indicates:
- an exceedance of temperature
- an exceedance of pressure limits
When is the starter valve open and closed? Which system operates the starter valve?
The starter valve is open when the Engine Start Switch is placed to GRD.
The starter valve is closed at 56% N2
The starter valve is operated by the DC system.
How does the Isolation Valve, in AUTO, work?
In AUTO the valve is:
- closed if both bleed air switches ON and both air con packs are in AUTO or HIGH
- open if any engine bleed air switch or air con pack is selected OFF
What does the DUAL BLEED light indicate?
DUAL BLEED indicates:
- APU bleed air valve OPEN and No 1 engine bleed switch ON
- No 2 engine bleed air switch ON, APU bleed valve open and isolation valve OPEN