DIRECT RADIOGRAPHY
is a way of converting XR's into electrical charges by means of direct readout process
COMPUTED RADIOGRAPHY
Use storage phosphor image plates w/separate readout image
3 WAYS TO PROCESS A DIGITAL IMAGE
PHOTOSTIMULABLE PHOSPHOR (PSP)

FLAT PANEL DETECTOR (FPD)

CHARGED COUPLE DEVICE (CCD)
WHAT IS THE PROCESS FOR DR?
RECORDED DIRECTLY ONTO AN ELECTRICALLY READ DEVICE
CASSETTE BASED
PHOTOSTIMULABLE PHOSPHOR (PSP)

1. IMAGE IS FORMED BY XR PHOTON EXCITATION OF PHOSPHORS

2. READER RELEASES STORED LIGHT AND CONVERTS IT TO ELECTRICAL SIGNAL

3. ELECTRIC SIGNAL IS READ BY READER THAN DIGITIZED
CASSETTE LESS
PHOTOCONDUCTOR CONVERTS XR PHOTONS DIRECTLY INTO SIGNALS.

Direct/Indirect Conversion

Flat panel detector (FPD)
Charged couple device (CCD)
BARIUM FLUOROHALIDE
CASSETTE BASED PSP
CASSETTE BASED CR IMAGING PLATE LAYERS
1. PROTECTIVE LAYER
2. PHOSPHOR LAYER
3. REFLECTIVE LAYER
4. CONDUCTIVE LAYER
5. SUPPORT LAYER
6. BACKING LAYER
PHOTOSTIMULABLE PHOSPHOR
STORES ENERGY DEPOSITED BY THE XR BEAM ON PLATE IN CRYSTAL PHOSPHOR CENTER
TRANSLATION
WHEN LASER SCANS ACROSS IP MULTIPLE TIMES AS IT MOVES THROUGH READER

THIS THEN RELEASES TRAPPED ELECTRONS, EMITS LIGHT THROUGH OPTICAL FILTER TO PHOTODETECTOR/PHOTOMULTIPLIER
ADC
ASSIGNS EACH PICTURE ELEMENT (PIXEL) A VALUE THAT CORRESPONDS TO LEVEL OF BRIGHTNESS
SPATIAL RESOLUTION
AMOUNT OF DETAIL PRESENT IN ANY IMAGE
SPEED OF FILM
DETERMINED BY SIZE AND LAYERS OF CRYSTALS IN FILM AND SCREEN
SPEED IN DIGITAL
DETERMINED BY LEVEL OF EXP. RECIEVED BY IP (DETERMINED BY MANUFACTURER)
ADVANTAGES OF CR
1. EASILY INTEGRATED INTO EXISTING SYSTEMS
2. EXCELLENT FOR PORTABLE, BEDSIDE/IMMOBILE PT. EXAMS
3. WIDE DYNAMIC RANGE
IP ARE SIMPLE TO REPLACE
CE (CONVERSION EFFICIENCY)
AMOUNT OF LIGHT ADMITTED FOR EACH XR ABDORBED
LUMINESCENCE
ANY MATERIAL THAT ADMITS LIGHT IN RESPONSE TO SOME OUTSIDE STIMULATION
FLUORESCENCE
IF VISIBLE LIGHT IS EMITTED ONLY WHILE PHOSPHOR IS STIMULATED
PHOSPHORESCENCE
IF PHOSPHOR CONTINUES TO EMIT LIGHT AFTER STIMULATION
DQE (DETECTIVE QUANTUM EFFICIENCY)
% OF XR'S ABSORBED BY SCREEN AND HOW ACCURATELY THEY ARE COVERED TO IMAGE