THE DUTY FACTOR OF CW ULTRASOUND IS ___________________.
100%
AS THE PULSE LENGTH DECREASES, THE PULSE DURATION...
DECREASES
AS THE PERIOD INCREASES, THE PULSE DURATION...
INCREASES
AS THE PROPAGATION SPEED INCREASES, THE PULSE DURATION...
STAYS THE SAME
AS THE FREQUENCY INCREASES, THE PERIOD...
DECREASES
AS THE FREQUENCY INCREASES THE WAVE LENGTH...
DECREASES
AS THE WAVELENGTH INCREASES, THE PROPAGATION SPEED...
STAYS THE SAME
AS THE FREQUENCY INCREASES, THE SPATIAL PULSE LENGTH...
DECREASES
AS THE PERIOD INCREASES, THE SPATIAL PULSE LENGTH...
INCREASES
AS THE PULSE DURATION INCREASES, THE DUTY FACTOR...
INCREASES
AS THE FREQUENCY INCREASES, THE PULSE DURATION...
DECREASES
AS THE PRF INCREASES, THE DUTY FACTOR...
INCREASES
AXIAL RESLUTION IMPROVES AS THE FREQUENCY...
INCREASES
AXIAL RESLUTION IMPROVES AS THE PULSE LENGTH...
DECREASES
THE NUMBER OF CYCLES PER UNIT TIME.
FREQUENCY
THE NUMBER OF CYCLES PER PULSE DETERMINES THE __________
SPL
THE DISTANCE OF ONE CYCLE.
WAVELENGTH
THE FRACTION OF TIME THAT PULSED ULTRASOUND IS ACTUALLY ON
DF
MAINLY DETERMINES THE AXIAL RESOLUTION IN PW U/S.
SPL
THE WAVELENGTH DIVIDED BY THE PERIOD.
PROPAGATION SPEED
THE TIME FOR ONE TOTAL TRANSMIT AND RECEIVE SEQUENCE
PRP
LISTENING AND DEPTH OF VIEW
DIRECTLY
WAVELENGTH AND SPL
DIRECTLY
PRP AND PRF
INVERSELY
MAXIMUM IMAGING DEPHT AND PRF
INVERSELY
MAXIMUM IMAGING DEPTH AND SPL
NOT RELATED
IMAGE QUALITY AND PULSE DURATION
INVERSELY
SPL AND PD
DIRECTLY
Pulse duration:
CANNOT BE CHAGED BY SONOGRAPHER
PRP
CAN BE CHANGED BY SONOGRAPHER BY USING DEPTH
Wavelength
CANNOT BE CHANGED BY SONOGRAPHER
F
CANNOT BE CHANGED BY SONOGRAPHER
SPL
CANNOT BE CHANGED BY THE SONOGRAPHER
WHAT ARE THE UNITS FOR INTENSITY?
WATTS DIVIDED BY CM SQUARED
By changing the imaging depth, which of the following does the operator also change.


PRF:
Duty factor:
PRP:
PRP :
SPL:
Amplitude:
PRF, DF, AND PRP
Period
DECREASES
Frequency
INCREASES
WAVELENGTH
DECREASES
SPEED
REMAINS THE SAME
PRF
REMAINS THE SAME
PRP