tesla =
|
10,000 gaus
|
|
precision
|
wobble
|
|
larmor frecuency
|
all protons in the nucleus will rotate with the same frequency
|
|
gyromatic ratio
|
a moment of inertia of a spinning nuclei in a magnetic field
|
|
type of coils to control pulsing
|
gradient
|
|
coils close to the body part
|
surface or radiofrecuency coils
|
|
coils in the wall that evens out the magnetic field
|
shim
|
|
heavy magnet, .3 T
|
permanent
|
|
magnet that produces lots of heat due to lots of resistance. .02-.4 T
|
resistive
|
|
uses liquid cryogen in thermos like container (dewar)
|
superconductive
|
|
layering of cryogens is
|
ramping
|
|
when boiling point is reached and safety valves release the gas
|
quenching
|
|
stainless steel staples or surgical implants gt hot
|
tourqing
|
|
scans head only
|
first generation
|
|
first to scan whole body
|
second generation
|
|
rotates 360 degrees within gantry. 4 scans per minute.
|
third generation
|
|
15 scans per minute. scans both clockwise and counterclockwise
|
fourth generation
|
|
dedicated to cardiac imaging. also referred to as electron beam tomography
|
fifth generation
|
|
helical/spiral. uses slip ring technology to allow continuous rotation around gantry. entire abdomen scanned in 30-40 seconds
|
sixth generation
|
|
MSCT. entire chest or abdomen scanned in 15-20 seconds.
|
seventh generation
|
|
software allowing data to be changed from transverse to coronal. also used for targeting.
|
reformation
|
|
where the beam is collimated in CT
|
at the tube and detector
|
|
type of detector used in most modern day CT scanners
|
solid state
|
|
3 attributes to detectors
|
high stability, fast response time, wide dynamic range
|
|
motion artifact
|
result of scan time
|
|
when 2 adjacent object have more than 60% difference in attenuation coefficients is also known as
|
star/interface artifacts
|
|
looks like quantum mottle
|
too much noise not enough data
|
|
section interval
|
difference between scan sections
|
|
problem with biplane vascular imaging
|
increased scatter radiation. eliminated by alternating the exposures.
|
|
vascular generators operate at
|
higher mA and low kVp
|
|
pulsing of the beam in a grid controlled tube is done using
|
third electrode located inside the tube that briefly turns the focusing cup positive.
|
|
visualization is of a contrast filled vessel is better with
|
low kVp
|
|
98.6 degrees farenheight is = to _____ degrees celsius
|
37
|
|
biplane imaging refers to
|
2 c arms 90 degrees from one another
|