Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
11 Cards in this Set
- Front
- Back
Which personal radiation monitoring devices can be charged with DC voltage to "zero" the device prior to use?
|
Self-reading pocket dosimeter
|
|
___ readings must be considered innacurate when they are dropped
|
SRPD
|
|
More sensitive to gamma radiation than beta radiation
|
SRPD
|
|
Least accurate in determining the dose rate to a human body from an unspecified source of radiation
|
Geiger-Mueller
|
|
What happens to pressure and velocity of water as it passes through a venturi?
|
pressure increases, but the velocity decreases as the diameter increases
|
|
develops an output signal by measuring the differential pressure of the fluid as it passes through the device
|
Venturi
|
|
Largest unrecoverable head loss when used in an operating fluid system?
|
Orifice
|
|
For steam flowing through a venturi, the relationship must be modified to account for changes in _____ as the steam flows through the venturi.
|
Specific Volume
|
|
The change in pressure across a main steam line flow element is ....
|
directly proportional to the volumetric flow rate
|
|
The density compensating input to a steam flow instrument is used to convert volumetric flow rate to ____
|
Mass Flow Rate
VM |
|
If the flow rate through a differential pressure detector flow nozzle doubles, by what factor would the D/P increase?
|
4
|