Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
10 Cards in this Set
- Front
- Back
What system is used to record and report all power 2 emissions? |
GPI |
|
What does 100/200 CEMS measure? |
PPM NOX, PPM CO, %O2 |
|
Where is 100/200 CEMS located? |
N/S pipe way between 100/200 (West side) |
|
What are the normal ranges for nox and CO on 100/200? |
200 - 300 lb/hr nox <30 lb/hr CO |
|
What type of monitoring is used for 300 emissions? |
PEMS |
|
What is used to control nox? |
Steam injection |
|
If CO was high on 100/200 what should be done? |
Identify the duct burner causing the issue and shut it down. |
|
What should be done if the CEMS analyzer fails Cal? |
Write work request and call analyzer tech asap |
|
What does Rata stand for and how often is it done? |
RELATIVE ACCURACY TESTING, YEARLY |
|
What air permit must power 2 comply with? |
Title v |