Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
43 Cards in this Set
- Front
- Back
BEvT
|
Battery Evaluation Time
Time in seconds the tool averages battery voltage for evaluation purposes. 10 seconds |
|
BThr
|
Low Battery Threshold
The voltage threshold below which the tool will alert the operator or switch to battery 2. LoVWthr in XXT 23 volts |
|
CMTF
|
Correct for Magnetic TFA Declination
Enables or disables the correction for magnetic declination at surface or down hole. Surface |
|
DiAA
|
Auto Data Acquisition Control
Allows putting the directional data acquisition process in automatic data mode for test purposes. Off |
|
DipT
|
Dip Angle Tolerance
.60 degrees |
|
DwnL
|
Downlink commands
Enables or disables the Downlink capabilities of the system. Disable |
|
EvIM
|
Evaluation Mode
Tells the tool to derive the inclination during the survey sequence only, or during both the survey and toolface/logging sequence. Survey |
|
FDM
|
Flow Detection Method
Switch |
|
FEvT
|
Flow Evaluation Time
How long the flow input must indicate a state change before the system will respond to the change. Stored in the tool. Must be the same as PEvT. 5 seconds |
|
GrvT
|
Gravity Magnitude Tolerance
.006 |
|
Gsf
|
Gamma Scale Factor
Multiplier which is applied to gamma counts. 1 |
|
GSPC
|
Gamma Sensor Power Control
When enabled, the sensor is powered only during flow conditions. Always set to enable. Enable |
|
HdCK
|
Type of Header Check Bits
The method used to confirm the accuracy of received data. Parity |
|
HiPL
|
High pulse Amplitude Limit
Pulses higher than this limit will not be reported or processed. Set to a value higher than the pulse amplitude. The ratio of HiPL:LoPL is typically set to approximately 10:1, but can be adjusted as needed. 300 PSI |
|
IncT
|
Inclination Threshold
The inclination at which the tool will switch from magnetic to gravity tool faces. 5 degrees |
|
InvF
|
Invert Flow Sense
Off |
|
Loc
|
Jobsite Location
Enter the well name. From well plan |
|
LoPL
|
Low Pulse Amplitude Limit
Pulses lower than this limit will not be reported or processed. 30 PSI |
|
MagT
|
Magnetic Field Tolerance
.005 |
|
MDec
|
Magnetic Declination
degrees |
|
ModN
|
Mode Number
Determines which of the four different modes the tool will use. 1 |
|
NDip
|
Nominal Dip Angle
From Well Plan |
|
NGrv
|
Nominal Gravity
1.000 G |
|
NMag
|
Nominal Magnetic Field Strength
From well plan |
|
NSyP
|
Number of Sync Pulses
Number of single wide pulses in a sync word. 4, 3 in benchtree |
|
PALMode
|
Pulse Amplitude Limit Mode
When manual, the system uses the defined LoPL and HiPL. When auto, the system calculates the LoPL and HiPL. Auto in XXT, not available in benchtree. |
|
PEvT
|
Pumps On/Off Evaluation Time
How long the pumps input must indicate a state change before the system will respond to the change. Must be the same as FEvT. 5 seconds |
|
PmpT
|
Pumps On Threshold
The pressure threshold above which the receiver considers the pump to be on. The setting for this variable depends on the expected pressure. 500 PSI |
|
PTfs
|
Pressure Transducer Rating
The nominal pressure rating for the pressure transducer. Usually set to 10000 PSI |
|
PTG
|
Pressure Transducer Gain
A multiplier used to increase pressure readings. 1 |
|
PTO
|
Pressure Transducer Offset
0 |
|
PWTmg
|
Type of Pulse Width Timing
Use narrow when the signal noise ratio decreases and there is a low level of pulse distortion. Use wide when pulses become distorted and are being rejected. Normal |
|
RxDT
|
Receiver Delay Time
The time delay required from pumps on until the receiver begins looking for signals from the tool. 45 sec |
|
RxFBwF
|
Filter Bandwith Factor
1 |
|
SHSz
|
Survey Header Size
The number of bits in a survey header. 3 |
|
SuAM
|
Survey Acquisition Mode
Tells the tool whether to acquire survey data during the "Flow" or "No Flow" state. No Flow |
|
SuDT
|
Survey Acquisition Delay Time
Delay time from a "No Flow" state until the data acquisition process occurs. 25 sec |
|
SyTy
|
Sync Word Type/Format
The type of Sync word generated by the tool. 1111 |
|
SyWF
|
Sync Window Factor
The amount of time that the receiver will look for sync pulses, before indicating that it missed sync. A value of zero indicates an infinite sync window. 0 |
|
THSz
|
Toolface/Logging Header Size
The number of bits in a toolface/logging header. 3 |
|
TLTx
|
Toolface/Logging Transmission Time Limit Control
In mode 1,2,3 or 4. Tells the tool how long, in minutes, to transmit toolface/logging data. A value of zero means the tool will continue to transmit data until pumps off. 0 |
|
TmpT
|
High Temperature Threshold
125 |
|
TxDT
|
Transmit Delay Time
The time delay required from "Flow On" until the tool begins to transmit signals 60 sec |