Rollover protection must peform at this temp |
0 degreed F |
|
Hierchary of Controls |
Engineering, Administrative and PPE |
|
Practice of connecting two metal objects to prevent static discharge |
Bonding |
|
Repetitive and similar task require briefings at start of each shift |
Subpart V |
|
Gaurd rail top rail |
42 +/- 3 inches |
|
Scaffold erection/dismantling |
Must be supervised by competent person |
|
Construction safety standard |
1926 |
|
Fall protection required when working on a scaffold |
Over 10 feet |
|
Signed OSH Act into law |
Nixon |
|
OSH Act created |
1971 |
|
Crane operators must be |
Certified |
|
Limited access zone must be the height of the wall plus |
4 feet |
|
Industrial truck training requirememts are found in |
1910.178 Powered Industrial Trucks |
|
Scaffold cross braces may serve as a mid rail when |
20 to 30 inches above platform |
|
Standard for eye and face protection |
ANSI 87.1 |
|
Standard for respirators |
1910.134 |
|
Responsible to train signal person |
Employer |
|
When signal are interrupted between signalman and operator |
Safely stop operations |
|
Defective portable ladders must be |
Removed from service |
|
Has the authority to refuse to handle crane loads |
Crane operator |
|
Prior to each shift |
Rigging must be inspected |
|
Type A soil |
May be sloped at 1/2:1 when depth is less than 12 feet |
|
Days worker was only able to work a partial shift |
Classified as restricted work activity |
|
Accident prevention and warnings signs must be |
Visible |
|
Height at which masonry walls must be braced |
8 feet or greater |
|
After showing credentials an OSHA inpection includes OSHA inpection includes |
Opening conference, walk around inspection closing conference |
|
Minimum clearance of hanrails between rail adn wall |
3 inches |
|
Soil having a compressive strength of 1.2 tons pers square foot |
Type "B" soil |
|
Ladder must be designed such that they ccan support |
4 times the max load |
|
Material chutes must be enclosed when |
Greater than 45 degrees |
|
Maximum height at which a controlled decking zone may be used |
30 feet |
|
Maimum voltage before gaurding is required |
Greater than 50 volts |
|
Creating employer failed to inform employees |
Creating employer recieves a citation under the multi-employer citation policy |
|
Max deceleration distance |
3.5' |
|
Person with a recognized degree or professional standing |
Qualified person |
|
Maximum distance to a fire extinguisher |
100 feet |
|
Number of incidents per 100 full time employees per year |
OSHA incident rate |
|
Leadership should always |
Be an example by knowing and complying with rules |
|
Hand and power tools |
Maintained in a safe condition |
|
When mechanical equipment is used on a roof |
Warning lines must provide a safe distance of 10 feet |
|
Welding opertations should be this when practical |
Shielded |
|
Failure to remove grease on regulator fitting could result in |
An explosion |
|
Two main components of an employer health and safety program |
Safety and health programs and competent person inspections |
|
Employer are responsible to |
Maintian accident prevention programs |
|
Used when a condition is not covered by a specific standard |
Horizontal standards |
|
OSHA mission OSHA mission |
Protection the safety and health of workers |
|
OSHA requires an employer abate |
All cited violations |
|
Protection of workers rights and guard against retaliation |
Section 11 (c) of OSH Act |
|
Toxic to male and female reproductive systems |
Lead |
|
Ensure a worker is trained in first aid and willing to render aid |
When no medical facilities are in the vicinity |
|
Product of workplace illness and injury |
Reduce morale and increase training costs |
|
Portable drinking containers |
Must have a tight lid and tap |
|
Ensure consistent implementation of OSHA standards |
Purpose of directives and enforcement |
|
Fall protection must |
Ensure a freefall of less than 6ft |
|
Assured grounding programs |
Not a part of a buildings permanent wiring |