Model |
Onan CMHG 10000
|
|
Watts, Hz
|
10000/ 60 hz
|
|
Weight, length, width, height of generator?
|
277lbs./ 32x16"x13.8""
|
|
RPM for operation?
|
3600
|
|
Amps ?
|
83
|
|
Gallons in Hydraulic tank and fluid?
|
3 gallons of Dextron III
|
|
Pump displacement?
|
74cc
|
|
What items are located on top of the Hydraulic fluid reservoir?
|
Filter and filter restriction gauge
|
|
How is the generator powered?
|
PTO driven with maxi on and transmission in neutral.
|
|
How many places can you start the Generator?
|
2- one in the cab and one in the first copartment on the drivers side/trailer.
|
|
Starting method #1
|
1) push Gen PTO" switch in cab. 2) watch for Gen Peto Engaged light to come."
|
|
Starting method #2
|
1) roll up door on engineer side, first compartment on driver side/trailer. 2) Push generator on/off switch until generator stars and both green lights illuminate.
|
|
The powerOn" has ____?"
|
2- 2 amp fuses mounted directly below the light.
|
|
A breaker panel is located where?
|
Same compartment as controls. The breakers should always be in the on position. |
|
The breakers control what excessories?
|
2- Main breakers, 2- aerial breakers, 2- DS Flood, 2- PS Flood, 1- DS Cab Flood, 1- PS Cab flood, 1- DS Cord reel, 1- PS cord reel, 1- DS receptacle, 1- PS Receptacle. |
|
Digital Readout gauge?
|
Gauge will read the Hz and Amps being used and display the voltage being produced as well. Other readings include, total run time hours, Oil temp. in degrees. |
|
How do you scroll through the different readouts for the Gauge?
|
By pressing the green Mode" button." |
|
Where are the power plug locations?
|
J box on 200' cord reel with 4 outlets x2, One plug on each side of truck behind the tiller tire., Each side of the aerial ladder at the tip (used to pwr. lights at the tip) |
|
Where are the A/C Lights located
|
2-900w floods on each side (tot. 4), 2-750w telescoping floods on each side of back of cab (total of 2), 2-750w lights at tip of ladder. |
|
What amp are all the receptacles?
|
120v 20 amp.
|
|
Where are the switches to turn on the A/C lights.
|
900w: in the cab overhead console, 750 telescoping: on dimond plate on back of cab, Tip lights, on light themselves or on hubbell switch next to light at the tip. |
|
What are the main components of the generator system?
|
1) PTO off main transmission (top) 2) variable displacement displacement piston pump 3) Sump/ reservoir 4) Air cooled heat exchanger 5)Hydraulic motor with cooling fan directed on Heat exchanger 6) Air cooled alternator powered by the hydraulic motor.
|
|
Hydraulic flow
|
10.5 gallons per minute
|
|
Hydraulic Pressure range?
|
350-3500 psi |