Domestic imposed load

1.5

Hotel room imposed load

2

Typical office imposed load

2.5 above ground level, 3 at or below

Communal areas with tables imposed load

2

Classroom imposed load

3

Museum and art gallery imposed load

4

Shopping area imposed load

4

Timber floor SDL

0.5

Timber flat roof SDL

0.8

Timber pitched roof SDL

1.0

Internal RC SDL

3 not including slab

External RC slab SDL

2.75

Metal deck roof SDL

0.5 not including primary steel

Steel clad steel frame all up load

5-10

Masonry clad timber frame all up load

10-15

Masonry walls and precast concrete slab all up load

15-20

Masonry clad steel frame all up load

15-20

Masonry clad concrete frame all up load

20-25

One way slab s/d and span

L/22-30, 5-6m

Two way span concrete s/d and span

L/24-35 and 6-11

Flat slab concrete s/d and span

L/27 and 4-8

Close centre ribbed slab s/d and span

L/23 and 6-14

Coffered slab s/d and span

L/15-20 and 8-14

Post tensioned flat slab s/d and span

L/35-40 and 9-10

Rectangular concrete beam s/d and span

L/12 and 3-10

Flanged concrete beam s/d and span

L/10 and 5-15

Concrete column s/d and span

H/10-20 and 2.5-8

Concrete wall s/d and span

H/30-35 and 2-4

Retaining concrete wall s/d and span

H/10-14 (cantilever) and 2-8

Rule for concrete beam shear stress

Less than 2MPa

Shear stress in ribbed concrete slabs

0.6MPa

Stocky concrete column check

Minimum column dimension = Clear column height/17.5

Allowance for moment in concrete columns

Loads from floor immediately above multiplied by 1.25, 1.5, 2 for interior, edge and corner column

Concrete column area estimate for stocky columns

Ac= N/15, N/18, N/21 för C28/35 concrete containing 1,2,3% reinforcement

Slab reinforcement estimate

80-110 kg/m3

RC pad footing reinforcement estimate

70-90kg/m3

Transfer slab reinforcement estimate

150kg/m3

Pile cap/raft reinforcement estimate

115kg/m3

Column reinforcement estimate

150-450kg/m3

Ground beam reinforcement estimate

230kg/m3

Beam reinforcement estimate

220kg/m3

Retaining wall reinforcement estimate

110kg/m3

Stair reinforcement estimate

135kg/m3

Wall reinforcement estimate

65kg/m3

Heavy industrial building all up reinforcement estimate

125kg/m3

Commercial building all up reinforcement estimate

95kg/m3

Institutional building all up reinforcement estimate

85kg/m3

Steel primary beam/truss s/d and span

L/10-15, 4-12

Steel secondary beam/truss s/d and span

L/15-25, 4-20

Steel transfer beam/truss s/d and span

L/10, 16-30

Steel castellated beam s/d and span

L/10-15, 4-12

Steel plate girder s/d and span

L/10-12, 10-30

Steel vierendeel girders s/d and span

L/8-10, 6-18

Steel roof truss s/d and span

L/12-20, 10-100

Steel pitched roof truss s/d and span

L/5-10, 8-20

Steel light roof beam s/d and span

L/18-30, 6-60

Steel lattice roof girder s/d and span

L/12-15, 5-20

Steel space frame s/d and span

L/15-30, 10-100

Steel uc s/d and span

Single-storey: L/20-25, 2-8


Multi-storey: L/7-18, 2-4

Steel hollow section column s/d and span

Single-storey: L/20-35, 2-8


Multi-storey: L/7-28, 2-4

Steel columns in buildings 2-3 storeys with Max 7m spans

203 UC

Steel columns in buildings up to 5 storeys high

254 UC

Steel columns in buildings up to 8 storeys high (or low rise with long spans)

305 UC

Steel columns in buildings 8 to 12 storeys high

354 UC

Steel column load enhancement for moments

Top storey: 4x z-diff + 2x y-diff


Intermediate storey: z-diff + y-diff



Where 'diff' is the difference between span loads

I value of truss

I= Ac * d^2 / 2

Composite UB s/d and span

Primary: L/19, 6-10


Secondary: L/23, 8-18

Composite UC s/d and span

Primary: L/22, 6-10


Secondary: L/29, 8-18

Composite girder s/d and span

Primary: L/15, >12


Secondary: L/25, >12

Timber domestic floor (50 wide joists at 400) s/d

L/24 +25 to 50

Timber office floor (50 wide joists at 400) s/d

L/15

Timber rafters (50 wide joists at 400) s/d

L/24

Timber beams/purlins s/d

L/10-15

Timber independent posts s/d

Minimum 100mm2

Timber triangular truss s/d

L/5-8

Timber rectangular truss s/d

L/10-15

Timber plywood stress skin panels s/d

L/30-40

Typical brick size

215x102x65 +10mm for mortar

Typical block size

440x215x(75-215) +10mm for mortar

Masonry fire resistance

Typical 100mm wall: 2h structural, 4h non-structural

Geotechnical FoS for scheme design

2-3

Geotechnical design and abp usually controlled by

25mm settlement allowance

Geotechnical frost action typically negligible below

450mm below ground level

Max depth of pad and strip foundations

3m

Small and short piles are typically... While wide, long piles are typically...

Bored, cast in-situ and driven steel piles respectively

Pile max and min dimensions

75-2000mm diameter, 5-100m Long

Types of retaining structures

Cantilever r.w., gravity r.w., piling r.w., anchored r.w., king post, sheet pile, contiguous piled wall, diagram wall, secant bored piled wall