Scissors Lift & Boom Platform treat all overhead power lines and communication cables energized and stay at least.

10ft (3meters) Away

Where installed in raceways, conductors numbers ___ and larger shall be stranded.

4

The Maximum distance from the end of a corridor for a smoke detector in a hallway that is less than 10ft wide is.

20ft

Class B Style A circuit functions under what condition?

Single Ground

What is the minimum size copper equipment grounding conductor for a Rated 20amp branch circuit (14 awg) (12awg) (10awg) (6awg)

12 awg

The Minimum size of a Class 2single conductor is? (Awg) 26; 24; 22; or 18awg.

18awg

What is the minimum allowable voltage on a Class 1circuit? (Volts) 24; 28; 30; or 120 volts

30volts

Which of the following Classification is considered the most Dangerous? Class III, Division 1; Class II, Division 1; Class III, Division 2; Class I, Division 1

Class I, Division 1

How Many #14awg.THHN Conductor can be installed in a 1/2" Trade size EMT? 12; 10; 13 or 14

12

In a protected premises equipment with Emergency Voice Communications, alarm notification shall occur within how many seconds after activation of an initiating device? 30 sec; 20 sec;. 10 sec or immediately no delay.

10 Seconds

The time delay between the activation of an initiating device and the automatic activation of a local fire safety function shall not exeed ? Seconds 10 sec ; 20 Sec 30 sec or 90 sec

10 Seconds

The secondary power supply for emergency voice/alarm communication skills service shall be capable of operating the evacuation alarm? 2 hr; 1 hr; 15 min; or 5 min

15 min

To increase the amperes of two 12 volts batteries what connections need to be made?

The batteries should be connected in parallel

A water level supervisor signal initiating device shall be initiated when the water level falls____or rises___?

76mm; 76 mm

A water temperature supervisory signal initiating device for a storage tank shall indicate a decrease in water temperature to what level?

40 degres F

The maximum voltage for a NPLFA circuit is at what level?

600 Volts

How far from the end of a 20-foot wide corridor should a visible notification device be placed?

15 feet (4.57m)

What best describes the use of a Meyer's Hub?

An Electric raceway connector used for liquid tight pulled, junction or panel box coupling.

What would be the minimum depth of a non-metallic raceway without concrete encasement b installed under a parking lot?

24"

Smoke detector can be applied in order to initiate control of a smoke spread.

Recirculation of dangerous quantities of smoke within a building.

Where would a sequence of operations be found?

Provide in a Matrix included in the design documents permanent record

Heat Detector shall be selected for maximum expect ambient ceiling temperature. The temperature rating shall be at least how many degrees above max ambient?

20 degrees F

What would the temperature range be of a fixed temp, type spot heat detector with a white color coded band?

Intermediate

The owner of the building has to keep acceptance test reports for how long after a system has been approved?

Life of the System

Which of the following components is Not an acceptable method when using a non-metallic box?

A metal cover

Which of the following best describes why a fire alarm system should be intentionally grounded.

Provide noise suppression from EMI sources

When should smoke detector sensitivity be re-calibrated after an installation

Within 1 year

Upon primary power failure the second power supply of za fire system shall be automatically supply energy within how many seconds?

30 Seconds

If voltage is double,and resistance is half what is the effect on current?

Current would increase by X 4

The correct application of a voltmeter is to place the leads of the meter?

Directly across the source of power

A parallel circuit is best described as a circuit which?

Have more than one path for current to flow

The difference in voltage on a circuit with no-load, and the voltage of that circuit with a load is called what?

Votage drop

The term "Shall" when used in the National Fire Alarm Code indicates what?

Mandatory requirements

When using IMC raceway in a masonry wall which type of connector shall be used?

Concrete tight type

What is the minimum size ground conductor for telecommunication circuits?

No. 14


What color should a insulated ground conductor size NO. 6 for a equipment Ground be?

Green with two yellow strips

What's the difference between bonding or grounding?

Grounding is a connection to earth, accidental or Intentional, Bonding is attached metal parts

Manual pull station shall be mounted within how many feet of every exit doorway?

5 feet

What is FPLP

Fire Power Limited Plenum

What does NPLFA stand for ?

Non-power Limited Fire Alarm Circuit

In America Wire Gage system, the bigger the number is, means a?

Smaller the wire

What is the smallest size conductor for a Class 3 circuit?

Not smaller than 18

What is the maximum VA that can be applied to a Class 2 circuit at maximum voltage with an Inherently Limited AC Power Source?

75 Watts

Which is the best instrument used to test grounds?

Ohm Meter

A Central Station under maximum quiescent load shall have sufficient capacity to operate under secondary power for a period of?

24 hours

A combination Smoke integral Heat-Sensing fire detector shall be listed or approved for spacing not less than?

50 feet

In the implementation of field wiring the following would cause an increase in circuit resistance?

Loose wire connector or terminal on the circuit

On a 4 amp, 24 Volt Circuit with 12 ohms load resistance in series what would the voltage drop be across the load?

24 Volt

If located on a sidewall, line type heat detector shall be located from the ceiling not more than?

20 inches

The common size EMT raceway used in Non-power Limit fire alarm circuit is ?

1/2" to 4"

Current-Carrying Continuous Line-type Fire Detector shall be durably marked?

Power-limited fire alarm circuit

For smooth ceiling, all points on the ceiling shall have a detector within?

21 feet

To prevent contamination and reduce changes in factory sensitivity ranges smoke detectors shall?

Not be installed until after the construction clean up of all trades is complete and final

DACR

Digital Alarm Communicator Receiver

DACS

Digital Alarm Communicator System

DACT

Digital Alarm Communicator Transmitter

DARR

Digital Alarm Radio Receiver

DARS

Digital Alarm Radio System

DART

Digital Alarm Radio Transmitter

Find the current (I) when the Voltage (E)=120 Volts and the resistance=30 ohms

4 amps

The color mode on a resistor is brown, black, red, and gold. The value of the resistor is?

1000 ohms @ 5%

Basic unit of power is?

Watt

The color band that represents the tolerance of a resistor is the____ band?

4th

A circuit that mesures infinite resistance and zero current is ___?

An open circuit

A volt meter is connected in__ with the circuit being tested

Parallel

Which article within the NEC covers fire alarm system grounding?

250 and 760-6

Communication circuit are covered in NEC Article

800

The NEC is both sponsored and published by the

NFPA

Which of the following is the National Alarm Fire Code?

NFPA 72

When optical fiber control cables are utilized for fire alarm circuits, they shall be installed in accordance with Article?

770

Messenger supported wiring may use any of the following methods of support exept?

Attached to an existing messenger cable if a load calculation is performed to verify that weight will be supported

Unless specifically permitted, the over current protection shall not exceed___ amperes for No. 12 gauge conductor

20amps

Grounding conductors shall be connected by any of the following methods exept ?

A solder connection

A ground electrode system may be any of the following exept

A fire sprinkler lateral of least 2" in diameter

When using an interior metal water pipe as the grounding electrode, the connection shall normally be made with in___ feet of the pipe point of entrance of the building

5'

Where more than one electrode is used, each electrode shall not be less than___ feet from any other grounding system

6'

In both exposed and concealed locations, where a cable or raceway-type wiring method is installed through bored holes in joists, rafters, or wood members, holes shall be bored so that the edge of the holes is less than___ inches from the nearest edge

1 1/4 "

Directly buried cables are not required to be more than___ inches below ground

24"

At least ____ inches of free conductor, measured from the point where it emerges from it's raceway, shall provide at each outlet, junction, and switch point for spices

6 inches

When installing open wiring in "other spaces used for environmental air" which one of the following cable types is permitted.

FPLP