  • Front
  • Back

What is the min size water tank for a fire pumper apparatus

300 gal
What is the min ground ladder that should be carried on fire pumper apparatus
1 straight ladder w roof hooks1 extension ladder1 attic ladder

what is the min length soft suction to be carried on a fire pumper apparatus

15 ft
What is the NFPA standard for fire hose
1961
A min of _____feet of 2.5 hose is required on a fire pumper apparatus
800 ft

How many handlines nozzles are required on fire pumper apparatus that have a 200 gpm rating or above

1

What tips are for the playpipe or sb nozzle on a fire pumper apparatus

1", 1 1/8", 1 1/4"

What size dia hose and up is considered LDH
3.5 and up"
What is the min rating for the dry chem ext. to carried on fire apparatus

80-B:C

According to 1901 what type of threads should we use and stock
NHT, National Hose
Any intake 3.5 or larger has to be equipped with what?

An adjustable automatic pressure relief valve

as a min the following types of ladders shall be provided on the truck

1 attic ladder2 two straight ladders w folding hooks2 ext ladder

how many salvage covers are required on ariel fire apparatus what is the min size?

6, 12 X 18

How many axes are required on an Ariel Fire Apparatus (the truck)

5 total, 2-6lb flathead axes and 3-6lb pick head axes

how many feet of general use life safety" rope are required on a fire pumper apparatus"

150 ft

1500 gpm pumps must be able to take in water via 20 ft of suction hose and discharging water in not more than _____ seconds?

30 sec

The pump is tested and rated at what atmospheric pressure and what altitude or below?

29.9 in Hg and 2000' or less

The pump body is hydrostatically tested @ a gauge pressure of

500 psi, 10 min

No discharge outlet larger than_____ is allowed at the pump operators panel

2.5 in

the intake pressure-indicating device (gauge) will read from__to___

30Hg vac to 300 psi pressure

on a 1500 gpm pumper what is the max size/dia hard suction intake hose

6 in

Water tanks need to have what in order do control movement of water

Baffle (or swash partitions) min two transverse or longitudinal vertical type baffels

The rated vertical height of an ariel ladder is measured how

at full ext. straight up, from the ground to the outermost rung on the outermost fly section.

Rungs must have a min. outside dia. of on an ariel apparatus
1 1/4

The min load rating for each rung is on an ariel apparatus ladder

500 lbs
At the narrowest point the spacing between rails has to be at least
18 in

Top rails will have a min height of

12 in high

The rated horizontal reach (ariel apparatus ladder) is measured how

in a horizontal plane from the centerline of the turntable to the outer most rung of the outer most fly section when ladder is at full ext.

the max speed for rotation at the tip is_____the max lower/elevation_____ and the max ext/retract_____

2 ft/sec, 1 ft/sec, .5 ft/sec

The fixed monitor should swivle up and down____degrees and left to right ____degrees

135, 45 (from center)

The cables used to raise and lower the ladder have a safety factor of

5:1

when stability testing the ladder, a load of ____times the rated capacity will be suspended at the tip of the ladder at an angle of least stability

1/12 times

horizontal load testing requires a side load of____for ladders with a pre-pipped waterway

350 lbs

All foam tanks are required to have what to prevent pressure and vacuum occurring in the tank

A vent that functions only when the pump is in operation.

The minimum rated capacity for a Pumper apparatus

750 gpm

Minimum amt of 13/4 required for pumper fire apparatus
400'
how many pike poles are required on a Fire engine and what length

(1) 6' and (1) 8' or longer

what must each seating position have that complies with ANSI and has five point break away feature

high visibility traffic vest
on a fire pumper apparatus how many spanner wrenches are required
4 (combination type)
What is an initial attack fire apparatus

250 gpm pump (min), carries water and has hose designed for quick attack

on an ariel apparatus signs must be placed warning the operator of what?

electrocution hazard

on an ariel apparatus how many feet of utility rope of 5000 lb or greater rating is required

150'

what % grade are wheel chocks expected to hold an apparatus in place

20%

apparatus with a gvrw over 36,000 lb must be equipped with what to ensure adequate braking

an auxiliary (secondary) braking system

fire apparatus must have a_____ _____ sysytem that will allow it to move with in __ seconds of start up.
quick buildup, 60 seconds
an angle of approach front and rear must be a minimum of____degree on fire apparatus
8 degrees
the fuel capacity must allow the engine to drive the pump at 150 psi net pump pressure for how long
2 1/2 hrs
Where pumps are 1500 GPM or larger they shall be capable of taking suction through 20ft of suction hose for the rated capacity of the pump and discharging water in not more than ____ seconds.
45 seconds
pumps shall be capable of developing a vacuum of___at ____ ft by means of the pump priming system

22 in Hg, 2000'

pumps must be able to sustain vacuum for at least ___ min with a loss not to exceed ___ in Hg
5 min, 10 in Hg
Automatic pressure relief devices shall be adjustable from a minimum of ___ to at least ____psi.
90, 185
Automatic pressure relief devices shall discharge to ____
the atmosphere
Any drain or bleeder must have a minimum of ____piping
3/4 inch
true or false and voltmeter is not required on the pump panel
false it is req.
the master intake gauge must read from a vacuum of___ to a gauge pressure of___
30 inHg, 300 psi min
the master gauges on the pump panel must be __Inch ____ than the individual gauges
1, larger
pressure gauges for individual discharges must be within ___inches of the valve control
6
What kind of fluid is inside the pump panel gauges and why
Glycerin(or silicone if temps are below -60 deg F)
minimum lift for the pump test must be ____ft from the center of the pump intake to the surface of the water.
3ft
true or false the foam pump may be turned off during the pump test
TRUE
what grade must wheel chock hold an apparatus

20%