CHAPTER 1 |
GENERAL |
|
CHAPTER 2 |
WIRING & PROTECTION |
|
210 |
BRANCH CIRCUITS |
|
215 |
FEEDERS |
|
220 |
BRANCH CIRCUIT, FEEDER, & SERVICE CALCULATIONS |
|
225 |
OUTSIDE BRANCH CIRCUITS & FEEDERS |
|
230 |
SERVICES |
|
240 |
OVERCURRENT PROTECTION |
|
250 |
GROUNDING & BONDING |
|
CHAPTER 3 |
WIRING METHODS & MATERIALS |
|
CHAPTER 4 |
EQUIPMENT FOR GENERAL USE |
|
400 |
FLEXIBLE CORDS & CABLES |
|
408 |
SWITCHBOARDS, SWITCHGEAR, & PANELBOARDS |
|
410 |
LUMINAIRES, LAMPHOLDERS, & LAMPS |
|
422 |
APPLIANCES |
|
430 |
MOTORS, MOTOR CIRCUITS, & CONTROLLERS |
|
440 |
AIR-CONDITIONING & REFRIGERATING EQUIPMENT |
|
CHAPTER 5 |
SPECIAL OCCUPANCIES |
|
CHAPTER 6 |
SPECIAL EQUIPMENT |
|
680 |
SWIMMING POOLS, FOUNTAINS, & SIMILAR INSTALLATIONS |
|
CHAPTER 7 |
SPECIAL CONDITIONS |
|
700 |
EMERGENCY SYSTEMS |
|
725 |
CLASS 1, CLASS 2, & CLASS 3 REMOTE CONTROL, SIGNALING, AND POWER-LIMITED CIRCUITS |
|
760 |
FIRE ALARM SYSTEMS |
|
CHAPTER 8 |
COMMUNICATIONS SYSTEMS |
|
CHAPTER 9 |
TABLES |
|
314 |
OUTLET, DEVICE, PULL, & JUNCTION BOXES; CONDUIT BODIES; FITTINGS; AND HANDHOLE ENCLOSURES |
|
402 |
FIXTURE WIRES |
|
445 |
GENERATORS |
|
450 |
TRANSFORMERS & TRANSFORMER VAULTS (INCLUDING SECONDARY TIES) |
|
455 |
PHASE CONVERTERS |
|
490 |
EQUIPMENT OVER 1000 VOLTS, NOMINAL |
|
500 |
HAZARDOUS (CLASSIFIED) LOCATIONS, CLASSES I, II, & III, DIVISIONS 1 & 2 |
|
511 |
COMMERCIAL GARAGES, REPAIR & STORAGE |
|
514 |
MOTOR FUEL DISPENSING FACILITIES |
|
517 |
HEALTH CARE FACILITIES |
|
590 |
TEMPORARY INSTALLATIONS |
|
600 |
ELECTRIC SIGNS AND OUTLINE LIGHTING |
|
705 |
INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES |
|
TABLE 220.12 |
GENERAL LIGHTING LOADS BY OCCUPANCY |
|
TABLE 250.66 |
GROUNDING ELECTRODE CONDUCTOR FOR ALTERNATING-CURRENT SYSTEMS |
|
TABLE 250.102(C)(1) |
GROUNDED CONDUCTOR, MAIN BONDING JUMPER, SYSTEM BONDING JUMPER, & SUPPLY-SIDE BONDING JUMPER FOR ALTERNATING-CURRENT SYSTEMS |
|
TABLE 250.122 |
MINIMUM SIZE EQUIPMENT GROUNDING CONDUCTORS FOR GROUNDING RACEWAY & EQUIPMENT |
|
TABLE 300.5 |
MINIMUM COVER REQUIREMENTS, 0 TO 1000 VOLTS, NOMINAL |
|
TABLE 300.50 |
MINIMUM COVER REQUIREMENTS (OVER 1000 VOLTS) |
|
TABLE 314.16(B) |
VOLUME ALLOWANCE REQUIRED PER CONDUCTOR (BOX FILL) |
|
TABLE 402.5 |
ALLOWABLE AMPACITY FOR FOR FIXTURE WIRES |
|
TABLES 430.247, 430.248, 430.249, 430.250 |
MOTOR FULL LOAD CURRENT |
|
CHAPTER 9, TABLE 4 |
DIMENSIONS OF CONDUIT & TUBING |
|
CHAPTER 9, TABLE 5 |
DIMENSIONS OF INSULATED CONDUCTORS & FIXTURE WIRES |
|
CHAPTER 9, TABLE 8 |
CONDUCTOR PROPERTIES |
|
ANNEX C |
CONDUIT & TUBING FILL TABLES FOR CONDUCTORS AND FIXTURE WIRES OF THE SAME SIZE |
|
ANNEX D |
EXAMPLES |
|
240.6 |
STANDARD AMPERE RATINGS |
|
MOTOR EFFICIENCY FORMULA |
Eff = output / input = hp * 746 / I * E [*1.732 for 3-phase] |
|
MOTOR HP FORMULA |
HP = E * I * Eff / 746 |