  • Front
  • Back

What is the ID of an authorized breathing gas hose?

3/8"

Can a gas source be used to proof test a breathing gas hose?

No, due to the personnel hazard associated with the stored energy from the compressed gas

When inserting a hose barb into the hose, how much space are you required to leave between the end of the hose and fitting nut?

A .06" +/- .03" gap

What pressure is used to conduct a proof test?

Shall be conducted using twice (200%) the maximum system operating pressure.

What is the operating pressure for breathing air?

250 psi

What is used to conduct a load test on the breathing hose?

A 200 lb. dead weight

How long is the proof test conducted?

A minimum of 10 minutes

How is the load test conducted?

Hose assembly is lifted so that the 200 lb dead weight is 4-6 inches off the ground and is held there for 10 minutes.

After a load test is completed, what is the max "creep" allowed between the hose and fittings?

1/16"

What information is shown on the tag of a satisfactory tested hose?

- Manufacturer


- Date of Manufacture


- Test Activity


- Test Pressure


- Date

What is the ID of an authorized pneumofathometer hose?

1/4"

What type of waterproof communication connectors are used on the umbilical?

4-pin Marsh Marine Connectors

What must be done if, during assembly or repair, the D-Ring is cut and welded or otherwise altered to install the snap shackle?

The D-Ring must be weight tested to a 500 lb static load for a minimum of 10 minutes prior to installing the D-ring and shackle assembly to the umbilical assembly

What seizing material must be used to seize the strength members or combined communication/ strength members to the D-ring?

3/16" nylon cord

What seizing materials are used along the length of the umbilical assembly?

- Nylon Cord


- Polyken


- Duct Tape


- 3/16 marline

What intervals are used when seizing the umbilical assembly?

- 12"-18" for the first 50' (Diver end) and last 50' (Console end) of the umbilical


- The remaining length of the umbilical can be seized at intervals, as required by the user, but not to exceed 36"