When the footing and floor are poured simultaneously, this is called a

monolithic slab

Poor drainage causes what percentage of foundation problems?

80%

Transpiration is the removal of moisture from the soil.

True

It is the responsibility of the inspector to detect visible evidence of wood damage.

True

That portion of the foundation that transfers the structural load to the ground is the

footing

Drain tile at the base of a foundation should be covered with

gravel

To prevent settlement of expansive clay soil, a requirement is

water

When moisture in soil freezes, the soil

expands

Movement of a foundation in an expansive soil may be caused by

all of the above

A tree growing too close to a house is a clue to check the foundation closely in that area.

True

moisture maintenance program for silty soil may cause foundation failure.

True

Softwood trees include

all of the above

Decay and dry rot develop when moisture conditions exist.

True

Musty smells are associated with high humidity and decay.

True

A 2" x 4" board used as a stud would be 1 5/8" X 3 1/2" because of surfacing operations.

True

Which of the following items should an inspector write on the inspection report?

All of the above

The truss roof system has four parts.

True

In building a frame or wooden skeleton, studs rest on the sills, which are secured to the foundation wall.

True

Plugging vents in a pier-and-beam house

may cause moisture and mildew problems in the crawlspace.

Exterior walls of a frame residence include wooden members called

studs

Windows and doors do not require flashing on homes with contemporary wood siding.

False

Minimum chimney height above the roof line is three feet.

True

Water penetration into a home may be caused by

All of the above

All wood contains water.

True

Fungi and termites are often found together because they require similar environmental conditions.

True

real estate inspector must be familiar with registered grade trademarks.

True

A non-pressure wood preservative process is acceptable for lumber used in contact with the ground.

False

Decay fungi cannot seriously damage wood that has a moisture content below what percentage?

20%

The system of construction in which studs are continuous from foundation to roof is generally termed

balloon framing

The board that rests on the perimeter of a concrete slab floor would be the

sill plate

The maximum allowable moisture content of seasoned lumber is

19%

Rafter boards pulling away from the ridge board may indicate foundation movement.

True

Some woods demonstrate a natural resistance to fungus attacks.

True

Floor systems using steel channels require bridging to prevent racking.

True

The metal channel that supports the metal studs is called

track

Where would you find the heel-joint connections?

Ceiling joist connection to rafter

Cold form steel has a galvanized coating to protect it from corrosion.

True

The most common areas where failures develop in EIFS are

all of the above

EIFS should be a minimum of ________ above finish grade.

8 inches

Sealants used to repair EIFS walls should be approved by the manufacturer.

True

Ladders can dent, puncture, or scar EIFS.

True

Backwrapping onto the back side of the insulation board should be a minimum of 2 1/2".

True

Which roof has four sloping surfaces to the eaves?

Hip

How many square feet in a square

100

Older untreated cedar shingles have what class UL fire rating?

No fire rating

An individual should observe sunlight through a wood shingle roof.

True

A wood shingle roof must be at least three layers thick.

True

A cedar shake roof requires no underlayment.

False

Granules in asphalt shingles protect the shingles from the sun's rays.

True

What type of decking may sustain asphalt composition shingles?

All of the above

Built-up roofing should not be used on roof slopes of 4/12 or steeper.

True

Slate and tile roofs require underlayment.

True

What is the UL classification of slate and tile roofs?

A

A galvanized steel roofing panel does not require painting.

True

A stainless steel roof is all but maintenance free.

True

The metal roof panels can be furnished in various lengths up to

24'

When a metal roof is installed over a composition shingle roof, the old roof serves as

All of the above

When inspecting a metal roof, the inspector should report all

All of the above

Real estate inspectors may open any seals or locks on city water meters.

False

All water heaters must have a temperature-pressure relief valve installed.

True

What material cannot be used for the temperature-pressure relief valve line?

PVC plastic

A plumbing trap prevents which of the following from entering the house?

Sewer gas

What type of plumbing trap would you expect to find under a sink?

P-Trap

A trap may lose its water seal by

All of the above

A commode has a built-in trap.

True

A commode that is loose on the floor should be reset with a new wax seal.

True

An inspector should test the tile around the shower for loose spots or leaks

True

In which of the following may a cross connection occur?

All of the above

Fiberglass and steel showers require shower pans.

False

Minimum size of a grease trap interceptor is

100 gallon

The difference between a Class I and Class II aerobic treatment plant is

that Class II cannot be used for surface application.

Site service visits for aerobic plants should include

an evaluation of the process operation.

In an electrical circuit, voltage forces electricity to flow to all appliances.

True

Amperage is a flow of electrons required to produce operation of an electrical appliance.

True

A complete electrical circuit must have

All of the above

The service entrance is where electric power lines enter the house.

True

Electrical wires must clear all flat roofs by how many feet and driveways by how many feet?

8; 12

Two-wire service will be only _______ service

115v

The electric service panel delivers power only to 240V appliances.

False

Copper is a better conductor of electricity than aluminum.

True

What is the amperage of 14-ga copper wire?

15

What is the amperage of 12-ga aluminum wire?

15

GFCI-protected receptacles are found in

All of the above

Voltage is the measure of force at which electricity is delivered.

True

Electricity is sold in quantities of

kilowatt hours

Three-prong outlets do not require grounding.

False

The inspector should remove the electrical panel cover to observe

All of the above

If the house has only two wires that run from the power pole, the service is limited to

115 volts.

The EER designation as applied to an air-conditioner refers to

energy efficiency ratio

To operate properly, evaporative coolers require a low relative humidity.

True

A conventional heating/cooling thermostat is acceptable for heat pumps.

False

When inspecting a high efficiency heat pump with an electronic control panel and thermostat, the thermostat temperature setting should never be moved more than 4°F in either direction.

True

A geothermal system is more efficient year-round than a standard heat pump.

True

In a geothermal system, the evaporator section absorbs energy and the condenser section releases energy.

True

The length of the ground loop is determined by the type of soil and the building's heating and cooling loads which are based on

All of the above

Whether the ground loop is most efficiently installed depends on the type of soil.

True

The ground loop consists of several lengths of _____________ pipe.

polyethylene

The cost of installing the ground loop is the same for horizontal trenches, vertical boreholes, or submerger in a pond.

False

A geothermal system in heat mode can produce heated air in excess of 100°F.

True

A kitchen exhaust using a blower is more efficient than one using a fan.

True