  • Front
  • Back
WT2
Specs: 208+-2 F

High coolant temp

Yes Alarm

S16
WT1
217+-2 F

High coolant temp

Yes all

S17
OT2
245+-3 F

High oil temp

Yes Alarm
OP2
39+-2 psi

Low oil pressure
(armed after 600 rpm, 15-25 sec)

Yes Alarm

S15
OP1
30+-2 psi

Low oil pressure
(armed after 600 rpm, 15-25 sec)

Yes all

S14
SS3
2050-2200 RPM

Overspeed

Yes all

----------------

SS2

2010-2110 RPM
FL3 on MEP-208
~30 gal

low fuel level (starts 35 min timer)

Yes Alarm, ??
FL4 on MEP-208
~110 gal

high fuel level

Yes Alarm
S13
13 cm

low coolant level

Yes Alarm
S14
18 cm

low coolant level

Yes all
K107
56.5+-1 Hz (2-3 sec)

underfrequency relay 60 Hz
(armed after 600 rpm + 10 sec)

Yes Alarm, trip
K108
46.5+-1 Hz (2-3 sec)

underfrequency relay 50 Hz
(armed after 600 rpm + 10 sec)

Yes alarm, trip
K109
13-26 amps

reverse power relay

Yes Alarm, trip

K24
K110
239+-5 VAC

Overvoltage relay

Yes All

K23
K111
177 VAC (1.5+-1 sec)

undervoltage relay

Yes Alarm, trip
K114
130% overload

overcurrent relay (169 amps output of a line for 15-25 sec = 130% overload)

Yes Alarm, trip

K25
K115
28 VAC

ground fault relay (28 VAC across R100 = ground fault of 506 VAC @ .92 amps of T100)

Yes Alarm, Trip

K22
K116
V = less 5%
Hz = less .5
Phase Angle = 12+-6 degrees

synchrocheck relay (permissive device, ensures CB101 cannot close onto a live bus until parameters are met for paralleling)

Nothing

K21
OP3
4 PSI

Air box disconnect pressure switch (deenergizes air control valves L2A & L2B)

Yes All
M7
4 cycled start attemps

Crank cycle timer (cycles K3 through 4 cycles of 15/15 sec start attemps then locked out of K3 and energizes K16 relay)

Yes Alarm
FS1 on MEP-012
At top

Shutoff for Manual Mode

at 40 gallons, shuts off fuel

FS1 opens, K26 opens, K31 opens, voltage removed from fuel pump solenoid
FS2 on MEP-012
Second from top

Shutoff for Automatic mode

at 37 gallons, shuts off fuel
FS3 on MEP-012
Third from top

Turn on for Automatic mode (S20)

at 32 gallons, turn on fuel
FS4 on MEP-012
Bottom

Turn on for alarm in Manual or Auto mode

10 minutes remaining

at 17 gallons, alarm and horn
K33
Fuel Time delay module

Nothing
G1
Battery changer not operating

Battery charging alternator

Yes Alarm
S24
Blown fuse

Blown fuse indicator

Yes Alarm