• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/14

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

14 Cards in this Set

  • Front
  • Back
BATT switch
ON - Light extinguished

Battery connected to Battery Bus and to Battery Charger
When does the Battery Charger work?
Batt Switch - ON
Emerg power not in use
Refuel inverter not in use
Power present to charger (AC)
BUS 1 FAULT
Generator Bus Fault - trips and locks open the BTR

AC Tie Bus Fault - trips and locks open all BTRs

Reset ONLY by ACMX
SMOKE ELEC/AIR Selector
Used to isolate buses for smoke

3/1 OFF - Gen 3 sys/Pack 1 Air OFF, ECON mode OFF, CRTs full bright

2/3 OFF

1/2 OFF (Emer pwr transfer inhibited)
CABIN BUS OFF switch
OFF - Power removed from Cabin AC Ground Service Bus and Cargo Loading Bus
IDG Switches

DISC
---------
FAULT
DISC - IDG disconnect

FAULT - IDG Oil press LOW, IDG Oil Temp Hi, IDG oil diff temp out of limits
Generator Switches

ARM
---------
OFF
ARM - GCR CLOSED, ready for power transfer

OFF - GR OPEN (because GCR tripped open)

Pushing switch RESETs Generator (in manual mode)
AC TIE Switches

ARM
--------
OFF
ARM - TIE Relay OPEN

OFF - Switch commanded OFF, Relay OPEN

Either Light = relay open
DC Tie (1 or 3) OFF
DC tie is OPEN

Commanded or RCCB (Remote Controlled CB) Protective Trip
Emergency Power Selector

1 - Arm
2 - ON
1 - If power lost (L Emerg AC/DC), Batt powers L Emerg DC & AC thru Static Inverter

2 - On = Bat commanded to power L Emer AC/DC

Batt switch must be ON
Emergency Power Test
Note - Do Not perform test w/ "Bat Charging" alert

Tests -

Static Inverter
Left Emerg AC/DC Buses
ADG Circuitry
Battery Charger
Emergency Power on Battery Only
1 - Time
2 - Buses powered
3 - What do you have? (12 items)
1 - 15 minutes

2 - Batt Direct, BATT Bus, L Emerg. AC/DC

3 -
IRU, "A" IGN,
DEU #1, DU 1&3 (PFD, EAD)
CADC 1, Pitot Heat, Standby Instruments
MCDU 1, VOR 1, VHF 1, Interphone/PA
Stab Trim Handles
Emergency Power with ADG Deployed
1 - Time
2 - Buses powered
3 - What do you have? (14 items)
1 - 90 min in Hydraulic mode, UNLIMITED in Electric mode

2 - ADG Pwrs - L Emerg AC & #1 Elec Aux Pump (Hyd mode)
In Electric Mode - ADG BUS (L/R Emerg AC, Batt Charger), TR3 (L/R Emerg DC, Batt Bus)

3 -
IRU 1&2, A&B IGN,
DEU 1&2, DU 1,3,4,5,6
CADC 1&2
MCDU 1&2, FMC 2, ILS 2, VOR 1&2, VHF 1,2,3 (ACARS), HF2
Tank 2 L Aft Pump, Tail Tank Alt Pump, Batt Charger
Electrical Priority

1 - AC Tie Bus
2 - AC Gen Bus
1 - AC Tie - EXT Pwr, IDG

2 - AC Gen Bus - IDG, APU, (Ext Pwr)