  • Front
  • Back
APU PWR switch (Electric panel)

ON
----------
AVAIL
Switch starts APU (normal ops) and powers GEN buses

ON - APU powering any bus
AVAIL - Flashes until APU >95%. Steady - Power OK for transfer
START/STOP switch (APU panel)

ON
-------
OFF
ON - Switch pressed
- Flashes when starting, steady when ready
- during APU fire, flashes until switch selected OFF

OFF - Steady when APU shutdown initiated
- APU bleed valve CLOSES
- APU shuts down 90 seconds after
- remains lit until shutdown complete
Pulling the APU fire handle does what?
Emergency Shutdown
APU Fuel Valve Closes
APU Gen disconnects / deenergized
#2 Bleed Valve Closes
Agent is armed
A - APU FUEL light
B - AUP DOOR light
C - APU FAIL light
A - fuel pressure low
B - Inlet door not fully open (start) or fully closed (shutdown) Door begins to close 1 minute after shutdown
C - APU INOP
APU GEN switch

OFF
Resets APU Gen

OFF - gen on speed, but malfunction has occurred
APU will Auto Shutdown for:
(9 items)
Inlet door not open
Power failure
No light-off during start
High EGT or loss of signal
Fire warning
Reverse flow in bleed air system
Overspeed or loss of N1 or N2 signal
Loss of DC power
Low oil pressure or high oil temp
APU In-flight Limits
Start - up to 25,000 ft

Run - up to 30,000 ft (electric only)