HOW IS A FILTER RATED?
|
A FILTER IS RATED BY ITS ABILITY TO REMOVE PARTICLES FROM THE OIL.
|
|
WHAT DO COMBUSTION BY=PRODUCTS CONSIST OF?
|
CARBON
WATER ACIDS PARTIALLY BURNED FUEL VARNISH LACQUERS |
|
WHAT IS THE PURPOSE OF LUBE OIL & SYSTEM
|
LUBRICATE
COOL CLEAN PROTECT CUSHION SEAL HYDRAULIC ACTION |
|
OPERATION SPECIFICATIONS
SUMP CAPACITY FILTERS TOTAL OF SYSTEM CONSUMPTION OIL PRESSURE OIL TEMPERATURE |
SUMP CAPACITY = 30 GAL
FILTERS = 6 EACH TOTAL OF SYSTEM = 36 GAL CONSUMPTION .66 QUARTS PER HOUR OIL PRESSURE = 60 - 90 PSI OIL TEMPERATURE = 180 - 230 DEGREES |
|
OIL HEATER (H113)
WATT VAC |
300 WATT
240 VAC |
|
LUBE OIL PUMP
TYPE OF PUMP HOW MANY GEARS GPM INTERNAL PRESSURE RELEIF VALVE |
TYPE OF PUMP
HOW MANY GEARS = 2 GPM = 124 GPM @ 1800 INTERNAL PRESSURE RELEIF VALVE = 160 PSI |
|
HOW MANY DEGREES DO THE LUBE OIL COOLERS REDUCE THE OIL
|
APPROX 80 DEGREES
|
|
OIL FILTER HEAD CONTAINS A REGULATOR VALVE = PSI
FILTER BY-PASS VALVE = PSIG PISTON COOLING REGULATOR = PSI |
A REGULATOR VALVE = 50-70 PSI
FILTER BY-PASS VALVE = 37 PSIG PISTON COOLING REGULATOR = 26NPSI |
|
OP3
WHEN DOES IT ACTIVATE |
ACTIVATES: 40 PSI RISING
DEACTIVATE: 4 PSI FALLING |
|
BYPASS FILTERS
GPH WHAT % DOES IT FILTER AND WHAT MICRON |
3 GPH
FILTERS 97% OF 5 MICRON |
|
PRE LUBE PUMP
VOLTS GPM CHECK VALVE |
24v DC
2.5 GPM 10 LB CHECK VALVE |