• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/40

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

40 Cards in this Set

  • Front
  • Back
7 CFR
Code of Federal Regulations
US Department of Agriculture defines prime farmland.

Sustainable Sites 1: Site Selection
40 CFR
Code of Federal Regulations
Defines EPA Wetlands as continuously saturated ground that supports habitat.

Sustainable Sites 1: Site Selection. No wetlands within 100 Feet
50 CFR
Code of Federal Regulations
Threatened or Endangered Species.

Sustainable Sites 1: Site Selection
EPA CGP
EPA 832
Erosion and sedimentation control. Stabilize soil.

CWA: Storm Water Management

Sustainable Sites Prerequisite 1.
EPA CWA
Clean Water Act of 1997

Sustainable Sites 1. Maintain 50 feet clear to body of water.
EPA 840
Clean Water Act: EPA + USDA Clean Water Action Plan

Sustainable Sites 1
EPA 1992
Energy Policy Act of 1992
Sets baseline annual water consumption.

Water Efficiency 2, 3.1, 3.1
EPA CAA
Clean Air Act, Title V - Rule 608: Refrigerant Management.
LCGWP - Life Cycle Global Warming Potential.
LCODP - Life Cycle Ozone Depletion Potential

Energy and Atmosphere Prerequisite 3

Energy and Atmosphere 4
ASHRAE 52.2
MERV Filters

Use Merv 8 During Construction EQ 3.1
Use Merv 13 on Occupation EQ 5
ASHRAE 55
Thermal Environment Conditions for Human Occupancy. 80% Occupant Satisfaction Required.

EQ 7.1 Thermal Comfort Design
EQ 7.2 Thermal Comfort Verification
ASHRAE 62.1-2004
Ventilation for acceptable Indoor Air Quality

Mechanical Ventilation:
Minimum ventialtion rates in the breathing zone.

Natural Ventilation: Requirements for locations and size of openings. Permanently open to and within 25 feet of operable opening. Open are at least 4% of net occupiable floor area.

EQ Pre 1
ASHRAE 90.1-2004
Energy Standards for Buildings Except Low Rise Residential

Establishes baseline energy consumption based on building envelope and energy cost.

EA PRE 2, EA 1, EA 2
ASHRAE AEDG
Advanced Energy Design Guide

Alternative compliance path for office projects under 20,000 s.f.

EA 1
ASTM E408-71
Surface Heat Emmisions / Heat Island Effect

SRI Solar Reflectance Index

SS 7.1, 7.2
ASTM E779-03
Envelope Leakage Test. Measures art tightness of building envelope.

EQ PRE 2 -No Smoking
ASTM E1903
Site Assesment Brownfields

SS 3
ASTM E903
Surface Reflectance

SRI Surface Relectance Index

SS 7.1
SS 7.2
ASTM E1980
Calculation of Solar Reflectance Index SRI

Reflectivity and Emmisivity combined.

SS 7.2
IESNA RP-33-99
Illuminating Engineering Society of North America

Outdoor light pollution

SS 8
IESNA 90.1
Illuminating Engineering Society of North America

Indoor Light Leakage to Outside

SS 8
DOE CBECS
Commercial Building Energy Consumption Survey 2007

Alternative baseline to 90.1

EA 1, EA 2, EA 6
DOE IPMVP
International Performance Measurement and Verification Protocol.

Monitor Energy Consumption for 1 Year

ECM Energy conservation meathod

Option B
Stadard approach

Option D
Whole building simulation
EA 5
FEMA
Federal Emergency Management Agency

Flood Elevation Maps

SS1 100 year floodplane +5 feet
ISO 14021
Internation Organization of Standards

Defines Recycled Content

MR 4.1, 4.2
SMACNA
Sheet Metal and Air Conditioning Contractors National Associatation

EQ 3.1 Seal Joints in Ducts
NBI ABCP
New Building Institute - Advanced Building Core Performance

EA1
CTGPG 237
Carbon Trust Good Practice Guide

EQ2
CIBSE AM10
Chartered Institute of Building Service Engineers - Application Manual 10

EQ2
Energy Star
Appliances and Equipment Process Energy. 25% Occupant use energy.

EA1
Green-E
Renewable Energy Providers

EA-6 2 year contract with Green E provider
GS-11
Green Seal 11

Interior Paints

EQ 4.2
GS-03
Green Seal 3

Primers

EQ 4.2
GS-36
Green Seal 36

Adhesives

EQ 4.1
CRI
Carpet and Rug Institute

Also carpet adhesives, padding, and cushions

EQ 4.3
FSC
Forest Stewardship Council

CoC Chain of Custody Certificate

MR 7
SCAQMD Rule 1113
South Coast Air Quality Management District

Coatings

EQ 4.2
SQAQMD Rule 1168
South Coast Air Quality Management District

Sealants, Misc., Rubber, Plastics

EQ 4.1
BAAQMD Regulation 8
Bay Area Air Quality Management District

VOCs Miscellaneous

EQ 4
ACEEE
American Council for and Energy Efficient Economy

Greenscore on Emmisions, must meet minimum score of 40

SS 4.3
CARB
California Air Resources Board

Defines Zero Emissions Vehicle

SS 4.3