• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/60

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

60 Cards in this Set

  • Front
  • Back
Establishes source-specific standards to reduce air quality impacts. Sets VOC limits for wood finishes, floor coatings, stains, and shellacs.

MR - Low Emitting Materials
South Coast Air Quality Management District (SCAQMD) Rule 1113.
Establishes source-specific standards to reduce air quality impacts. Sets VOC limits for sealants and adhesives.

MR - Low Emitting Materials
South Coast Air Quality Management District (SCAQMD) Rule 1168.
Less efficient refrigerant. Has a high global warming potential (GWP).
HFCs
Defines methods for testing air cleaners for two things: a devices capacity for removing particles from the air, and the devices resistance to air flow.

MR - Indoor Air Quality
ANSI / ASHRAE 52.2 - 1999
Standard for energy efficiency except low rise residential buildings.

SS - Light Pollution
ANSI / ASHRAE / IESNA Standard 90.1-2007
Provides the baseline flow rate for fixtures.

WE - Water Use Reduction and Innovative Waste Water Technology
Energy Policy Act (EPAct) of 1992
Policy that enacts the EPAct of 1992.

WE - Water Use Reduction and Innovative Waste Water Technology
Energy Policy Act (EPAct) of 2005
Provides the baseline flow rate for commercial faucets.

WE - Water Use Reduction and Innovative Waste Water Technology
IPC / UPC 2006
Third party certification of water efficient fixtures.

WE - Water Use Reduction and Innovative Waste Water Technology
Water Sense
International agreement to reduce ozone depletion.
Montreal Protocol
Tests and certifies hard surface flooring for compliance with criteria adopted in California for indoor air emissions of VOCs.

MR - Low Emitting Materials
FloorScore Program
Sets VOC limits for anti-corrosive and anti-rust paints.

MR -Low Emitting Materials
Green Seal Standard GC-03
VOC test for cushion used under carpet.

MR - Low Emitting Materials
Carpet and Rug Institute (CRI) Green Label Program
Program that identifies carpet and adhesives with very low emission of VOCs to improve indoor air quality. It is an enhancement of another program.

MR - Low emitting Materials
Carpet and Rug Institute (CRI) Green Label Plus Program
Defines "Brownfield"

SS - Brownfield Redevelopment
U.S. EPA
Refrigerant scheduled for phase-out under Montreal Protocol. Has mid-range ozone depletion potential (ODP).
HCFCs
Provides concise description of best practice techniques for verifying energy performance.

EA - Measurement and Verification
International Performance Measurement for Verification Protocol (IPMVP) Jan. 2006
Specifies minimum ventilation rates and indoor air quality levels so as to reduce adverse health effects.

MR - Minimum Indoor Air Quality and Increased Ventilation
ASHRAE Standard 62.1-2007
Sets VOC limits for commercial adhesives.

MR - Low Emitting Materials
Green Seal Standard GS-36
Sets standards for commercial flat and non-flat paints.

MR - Low Emitting Materials
Green Seal Standard GS-11
Seal of approval for environmentally and socially responsible forest management. Used to certify wood.

MR - Certified Wood
Forest Stewardship Council (FSC) Certified Wood
Recycled content is defined in accordance with the following standard.

MR - Recycled Content
International Organization for Standardization (ISO) 14021-1999
The energy consumed during the stages of a materials life cycle.
Embodied Energy



(*vomit*)
The analysis of the environmental impacts of a service, material, or product through its entire existence.
Life Cycle Assessment
Commerical construction in the U.S. accounts for:

__% of potable water consumption
14%
Commerical construction in the U.S. accounts for:

__% of waste output
30%
Commerical construction in the U.S. accounts for:

__% of CO2 Emissions
38%
Commerical construction in the U.S. accounts for:

__% of raw material use
40%
Commerical construction in the U.S. accounts for:

__% of the solid waste stream
40%
Commerical construction in the U.S. accounts for:

__% of energy use
24%-50%
Commerical construction in the U.S. accounts for:

__% of electricity consumption
72%
Name all seven LEED credit categories.
Sustainable Sites (SS)
Water Efficiency (WE)
Energy and Atmosphere (EA)
Materials and Resources (MR)
Indoor Environmental Quality (IEQ)
Innovation and Design Process (ID)
Regional Priority (RP)
Defines "Zero-Emission Vehicle"

SS - Alternative Transportation
California Air Resources Board (CARB)
Defines "Fuel Efficient Vehicle"

SS - Alternative Transportation
American Council for an Energy Efficient Economy (ACEEE)
Voluntary certification and verification program for renewable energy products.\

EA - Green Energy
Center for Resource Solutions (CRS), Green-e Product Verification Requirements
Defines "Prime Agricultural Land"

SS - Site Selection
USDA
Agency that addresses flood elevation.

SS - Site Selection
FEMA
Defines "Wetlands"

SS - Site Selection
Code of Federal Regulation (CFR) of Wetlands
Provides guidelines for preparation of erosion and sedimentation control plan to comply with the National Pollutant Discharge Elimination Scheme (NPDES).

SS - Construction Pollution Prevention
EPA 2003
Refrigerant banned under Montreal Protocol. Has a a high ozone depletion potential.
CFCs
Identifies factors of thermal comfort and the process for developing comfort criteria fora building space and its occupants.

MR - Thermal Comfort
ANSI / ASHRAE 55-2004
Develops guidelines for maintaining healthful air quality during demolitions, renovations, and construction.

MR - Indoor Air Quality Management
Sheet Metal and Air Conditions Contractors National Association (SMACNA).
How many bonus points are available from ID and RP categories?
10
The ratio of the radiation emitted by a surface to the radiation emitted by a black body at the same temperature.
Emissivity
What product requires a "chain of custody" document?
FSC Certified Wood
Fire suppressant that causes ozone depletion. Phased out under Montreal Protocol.
Halons
High SRI materials help acquire credits in which two categories?
EA and SS
Which rating system requires accountability forms?
LEED for Homes
Heat Island Effect can typically raise temperatures by how many degrees?
10
Which catergory would be assisted by bioswales?
SS
What is the size requirements for the recycling collection area of a site?
There are no size requirements.
Which rating system requires durability manning and management?
LEED for Homes
Range of points required to achieve "LEED Certified"
40-49 points
Range of points required to achieve "LEED Silver"
50-59 points
Range of points required to achieve "LEED Gold"
60-79 points
Range of points required to achieve "LEED Platinum"
80+ points
USGSA Green Building Benefits are...

__% lower maintenance costs
13% lower maintenance costs
USGSA Green Building Benefits are...

__% less energy usage
26% less energy usage
USGSA Green Building Benefits are...

__% higher level of occupant satisfaction
27% higher level of occupant satisfaction
USGSA Green Building Benefits are...

__% lower CO2 emissions
33% lower CO2 emissions