WE 1.1 Water Efficient Landscaping: Reduce by 50%
What is Intent |
Limit or eliminate the use of potable water, or other natural surface or subsurface water resources near or on project, for irrigation.
|
|
WE 1.1 Water Efficient Landscaping: Reduce by 50%
What are requirements? |
Reduce potable water concumption for irrigation by 50% using:
Landscape coefficent (Kl) Irrigations effieciency (IE) Project specifice evapotranspiration (ETL) Use of Captured rainwater Use of recycled wastewater Use of water treated & conveyed by a public agency soecifically for non-potable uses |
|
WE 1.2 Water Efficient Landscaping: No Potable Water Use or No Irrigation
Requirements? |
No Potable water use
AND Use only captured water, recycled wastewater, recy. graywater, or water treated for special use of irrigation OR Install landscaping that doesn't require perm. irrigation |
|
WE 1.1-1.2 Water Efficent Landscaping
Technolgies and Strategies? |
*Perform Soil/climate analysis to determine native/adapted plants to use.
*Use high efficecy irigation stategies *Use drip systems (30-50% less water than sprinklers) |
|
WE 1.1-1.2 Water Efficent Landscaping
Submittals? |
The projects calculated baseline Total Water Applied (TWA) (gal.)
Baseline Case TWA (gal) = Area (Sf) X (ET(in/IE) X .6233 gal/sf/in. |
|
WE 2 Innovative Wastewater Technologies
Intent? |
Reduce generation of wastewater and potable water demand,while increasing the local aquifer recharge
|
|
WE 2 Innovative Wastewater Technologies
Requirements - Option 1? |
Reduce potable water use for building sewage conveyance by 50%. (water conserving plumb. fixtures, urinal, captured rainwater, graywater)
|
|
WE 2 Innovative Wastewater Technologies
Requirements - Option 2? |
Treat 50% of wastewater on site to teriary standards AND
Treated water must be infiltrated or used-on-site |
|
WE 2 Innovative Wastewater Technologies
Exemplary Performance |
*Zero Use f potable water in sewage conveyance
*100% on-site treatment and reuse/infiltration of wastewater |
|
WE 2 Innovative Wastewater Technologies
Technologies and Strategies? |
*Specfy. high effiency fixures, dry fixtures (composting toilets)
*Reuse sotrmwater or graywater *Options for w.w. treatment incl. Packaged biological nutrient removal, constructed wetlands, h.effc. filtration systms. |
|
WE 2 Innovative Wastewater Technologies
Submittls? Basic Assumption1? |
*Plumb. Construct. dwgs
*Calc. Basic Assumption Female 1: Male 1 or Project specific ratio Gallon per flush (GPF) WClost 1.6, Urinal 1.0 Daily use: WC male: 1 Urinal male: 2 Wcloset female: 3 |
|
WE 2 Innovative Wastewater Technologies
Submittals.continued Calculation: Basic Assump.2? |
Fixture GPF
Conv. WCloset 1.6 Low flow Wcloset: 1.1 Ultra low flow Wcloset: 0.8 Compst. toilet: 0.0 Conv. Urinal: 1.0 Waterless Urinal: 0.0 |
|
WE 2 Innovative Wastewater Technologies
Submittals.continued 3 equations: Basic Assump.2? |
Eq. 1 Sewage colume (gal) = Uses x Duration (flushes/min.) xWater volume/Use (flush/min.)
or Eq. 2 Daily sewage generation (gal)= Male occupants x male Sewage Generation (Gal) + Female occupants x Female Seage Generation (gal) |
|
WE 3 Water Use Reduction
Intent? Ref. Stndrd? |
Maximize water efficiency within buildings to reduce the burden on municipal water supply and wastewater systems.
Ref: Energy Policy Act (EPAct) of 1992 -- Deals with Water!!! |
|
WE 3.1 Water Use Reduction: 20% reduction
Requirements? |
Employ strategies that in aggregate use 20% less water then the water use baseline for the bldg. after meeting EPAct fixt. perf. requmnts.
-Don't include Irrigation -include: Wclosets, urinals, lavoratory faucets, showers, kitchen sinks. |
|
WE 3.2 Water Use Reduction: 30% reduction
Requirements? |
Employ strategies that in aggregate use 30% less water then the water use baseline for the bldg. after meeting EPAct fixt. perf. requmnts.
-Don't include Irrigation -include: Wclosets, urinals, lavoratory faucets, showers, kitchen sinks. |
|
WE 3.2 Water Use Reduction: 30% reduction
Exempllary Performance |
Reduce water consumptin by at least 40%
OR Ptable water use reduction in process and non-regulated water consuming fixtures by at least 10%. |
|
WE 3.2 Water Use Reduction: 30% reduction
Submittals? |
*Number of Bldg. Occupants
*Project design case *Project claculated baseline *Non-potable water use *Narrative |