Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
32 Cards in this Set
- Front
- Back
WHAT IS THE FIO2 RANGE OF A NRB?
|
.21-1.
|
|
WHAT DO YOU DO WHEN THE RESERVOIR BAG OF NRB COLLAPSES?
|
INCREASS THE FLOW
|
|
ON INHALATION A NRB DOES NOT SLIGHTLY CONTRACT...TROUBLESHOOT THIS PROBLEM?
|
TIGHTEN MASK TO PT. FACE
REPLACE MASK BECAUSE VALVE IS STUCK |
|
FIO2 OF RANGE A PARTIAL REBREATHER MASK?
|
.60-.65
|
|
FLOW OF A PARTIAL REBREATHER MASK?
|
6-10LPM
|
|
NAME ALL THE LOW FLOW DEVICES?
|
NASAL CANNULA
SIMPLE MASK PARTIAL REBREATHER MASK |
|
VENTURI MASK FIO2 RANGE?
|
PRECISE
(YOU ARE THE CONTROLLER) |
|
HOW DO YOU INCREASE OR DECREASE THE FIO2 OF THE VENTURI MASK?
|
BY CHANGING THE SIZE OF THE AIR ENTRAINMENT PORTS
|
|
FIO2 RANGE OF THE SIMPLE MASK?
|
.40-.55
|
|
FLOW RANGE OF THE SIMPLE MASK?
|
6-10LPM
|
|
EXPLAIN WHY SHOULD THE FLOW OF THE SIMPLE MASK BE GREATER THAN 5LPM?
|
TO FLUSH OUT EXHALED CO2
|
|
FIO2 RANGE OF THE NASAL CANNULA?
|
.24-.45
|
|
FLOW OF THE NASAL CANNULA?
|
1-6LPM
|
|
RULE TO APPROXIMATE FIO2 OF THE NASAL CANNULA?
|
FOR EVERY 1LPM INCREASE IN FLOW,THE FIO2 INCREASES BY 4%
|
|
FIO2 RANGE OF THE T-PIECE?
|
DEPENDS ON THE AEROSOL SOURCE
|
|
WHILE USING A T-PIECE,WHEN SHOULD YOU EXPECT TO SEE THE AEROSOL COMING FROM THE RESERVOIR TUBING?
|
DURING INHALATION
|
|
FIO2 RANGE OF THE AEROSOL MASK?
|
DEPENDS ON THE AEROSOL SOURCE
|
|
FIO2 RANGE OF THE TRACH COLLAR?
|
DEPENDS ON THE AEROSOL SOURCE
|
|
FIO2 RANGE OF THE FACE TENT?
|
DEPENDS ON THE AEROSOL SOURCE
|
|
WHERE DO YOU MONITOR THE FIO2 OF THE OXI-HOOD?
|
ANALYZE CONTINOUSLY NEAR THE INFANT'S FACE
|
|
FLOW RANGE OF THE OXI-HOOD?
|
7-14LPM
|
|
WHY IS THE FLOW RANGE SO HIGH FOR THE OXI-HOOD?
|
TO PREVENT CO2 BUILD UP
|
|
WHICH HUMIDIFIER HAS LOW RISK OF CROSS CONTIMINATION?
|
WICK
|
|
WHY DOES THE WICK HUMIDIFIER HAS LOW RISK OF CROSS CONTAMINATION COMPARED TO OTHER HUMIDIFIERS?
|
LOW RISK OF CROSS CONTAMINATION BECAUSE NO PARTICLES ARE BEING PRODUCED
|
|
HOW DO YOU APPROXIMATE THE FI02 OF A NASAL CANNULA SET AT 3LPM?
|
3 X 4 = 12
12 + .21 = 33% |
|
WHAT LITER FLOW SHOUL BE SET TO DELIVER AN FIO2 OF 40%?
|
5LPM
5LPM X 4%=20 20 + .21 = 41% |
|
BUBBLE HUMIDIFIER, WHAT WOULD PREVENT THE POP--OFF ALARM FROM SOUNDING?
|
A CLOGGED JET
|
|
BUBBLE HUMIDIFIER, A KINK IN THE TUBING WOULD CAUSE
|
THE WHISTLING ALARM TO SOUND
|
|
BUBBLE HUMIDIFIER, IF THE FLOW SETTING IS TO HIGH WHAT WILL OCCUR?
|
THE WHISTLING ALARM WILL SOUND
|
|
bubble humidifier, if there's an obstruction at the outlet what will occur?
|
THE WHISTLING ALARM WILL SOUND
|
|
WHEN THE CONNECTING TUBING ON A BUBBLE HUMIDIFIER IS OCCLUDED AND NO ALARM OCURS THIS WOULD BE CAUSED BY
|
A LEAK
|
|
HOW DOES SPACERS AND HOLDING CHAMBERS IMPROVE THE EFFICIANCY OF MDI'S?
|
BY INCREASING ORAL DEPOSITION
|