Personnel Required

One

Personnel working aft of station ___ inside the A/C with an APU running shall be equipped with suitable hearing protection.

900

If QSAS electrical power is interrupted in any way, what must the battery power switch be placed in?

EMERGENCY

Will the AC be left unattended while the QSAS is operated?

No

What cannot be open to allow QSAS electrical power to be applied to the AC?

External power receptacle door.

What is pressurized when APU is in normal mode? This is the reason you cannot run the APU with uncapped hydraulic lines.

Aircraft pneumatic manifold.

What will cause the APU to immediately shutdown potentially causing damage to the inlet muff or door linkage?

Disengaging the APU Battery.

Frozen door check should be performed if the temperature is below ___ F

40

What detent must the battery switch be in before applying QSAS electrical power?

EMERGENCY

Cargo compartment A/C control panel temperature control switch needs to be in what detent?

MANUAL

AC must have a minimum of ____ pounds in the No __ main tank prior to APU operation.

2,000 / 2

Ensure AIR CONDITIONING MASTER switch is in the ____ position

RAM AIR

When switched to APU BATT on the VOLTMETER, it should read?

27 (+/- 3) Vdc

If APU battery voltage is ___ V or less, APU battery must be replaced.

21

What happens when APU FIRE/DSBLD switch-indicator and 1 EXT/2 EXT switch-indicator is pressed?

lights come on

What should the APU accumulator gage read?

3,000 (+/- 350) PSI

What should the APU surge damper pressure gage read?

Pressure shown in chart (+/- 50 PSI)

Before starting, make sure generator switch is in the ___ position.

OFF

All starts must be initiated from where?

APU control panel.

Place and hold MODE SELECT switch in GEN ONLY position until applicable tachometer indicates ___ RPM.

60

Allow the APU to run for a minimum of ___ in the GEN only mode before switching to the NORMAL MODE.

60 seconds

When you first position APU START/STOP switch to start, what happens?

DRS OPN light comes on, tachometer accelerates to 100% in 11 seconds, RDY light remains out, EGT meter increases rapidly to 800F

When you position APU START/STOP switch to start for the second time, what happens?

RDY light comes on, EGT meter increases rapidly to 1200F.

If fan ducts on No 1 and/or No 4 engines are raised ensure what?

Flap handle is Up and Warning tag is attached to flap handle.

When SELECTOR VOLTMETER & FREQ METER on electrical control panel is placed to EXTERNAL POWER...VOLTS read / HERTZ read

200 (+/- 10) V / 400 (+/- 5) cycles

After applying power, when the SELECTOR AMMETER and VOLTMETER is rotated to TR1 and/or TR2...VOLTS read

27 (+/- 3) Vdc

After __ of charging, batter chargine current should be less that ___.

10 minutes / 9 A

What system needs to be pressurized to build APU accumulators before shutting down the QSAS?

Right system.

When the APU START/STOP switch is placed to STOP...what happens?

RDY light goes out, EGT meter drops slowly to 800 F in 1 minute.

After emergency stop on APU is initiated, it takes approximately ___ for intake and exhaust doors to close and ____ lights to go out.

30 seconds, DRS OPN

To initiate QSAS Emergency Stop, Momentarily press No 1 and No 2 ____ switches on QSAS control panel.

EMER STOP

After emergency stop on APU is initiated, No 1 and No 2 ____ lights go out if APUs were operating in normal mode.

APU RDY.

After emergency stop on APU is initiated, No 1 and No 2 APU rpm begins to ____.

Decrease.