Intensifying screens _____.
Emit light
True or False: Light exposing the film is in direct proportion to the amount and energy of the incident photon upon the screen.
True
Which modality was the first to use the principle of digital imaging?
-CT
-MRI
-Ultrasonography
-cardiac catheterization
CT
Who was the first to incorporate digital imaging with the CT scanner
Godfrey Hounsfield
The first commercial CT scanners could image the _____
Head only
In which decade was MRI first introduced?
1980's
Teleradiography incorporated ____ to produce radiographic images.
Telephone lines
Computed radiography acquires an image through _____
The use of a storage phosphor plate
True or False: When switching from a conventional diagnostic radiography room to one that incorporates computer radiography, major equipment changes are to be expected.
False
Storage phosphor plates are similar to ____.
Intensifying screens
In a digital radiography system, which of the following are needed to produce a radiographic image?
-X-ray absorber and a CCD
-Intensifying screen and a TFT
-Storage phosphor plate and a CCD
-Storage phosphor plate and a TFT
X-ray absorber and a CCD
True or False: Like CR, DR can use the existing diagnostic equipment found in today's imaging departments
False
True or False: Indirect capture DR converts absorbed x-ray energy into visible light.
True
The two elements needed to convert light signals into an electrical signal while using indirect capture DR are TFT and _____.
Photoconductors
The x-ray absorber typically used in direct capture DR is a _____.
Photoconductor
True or False: A bucky apparatus is required for digital radiography
False
Compared with a90-second processing time found in conventional radiography, image acquisition with DR has now been reduced to ____.
3 to 5 seconds
In conventional radiography film processing, the sensitivity speck has this electrical charge.
Negative
The active element in a storage phosphor is _____.
Barium fluorohalide
In reference to CR, to release the latent image, which of the following devices is scanned over the phosphor plate?
-Photomultiplier tube
-fluorescent light
-focused laser light
-lithium crystal
focused laser light
Which of the following best describes the sequence for image acquisition using computed radiography?
-phosphor plate, focused laser light scanner, photomultiplier, digital-analog converter, review station
-phosphor plate, focused laser light scanner, photodensitometer, digital-analog converter, review station
-phosphor plate, focused laser light scanner, photodensitometer, analog-digital converter, review station
-phosphor plate, focused laser light scanner, photomultiplier, analog-digital converter, review
phosphor plate, focused laser light scanner, photomultiplier, analog-digital converter, review station
X-ray energy related to direct capture DR will stimulate a _____, which eventually is changed into electrical signal
Scintillator
The _____ converts x-ray energy directly to a digital electrical signal.
Photoconductor
Another name for exposure latitude is _____.
Dynamic range
A look-up table maps _____.
Image gray scale values
With conventional radiography, optical density is primarily controlled by _____.
Milliampere-seconds
Barium fluorohalide phosphor screens have a k-edge at ____ keV.
37
True or False: DICOM is a standard that allows imaging modalities and PACS to communicate in the same language.
True
All of the following are components of PACS except ____.
-independent KVp and mAs stations
-web access
-multiple interfaces
-reading stations
independent KVp and mAs stations