______ load is when a space is to cold
|
Heating
|
|
______ load is when a space is to Hot
|
cooling
|
|
4 grains of moisture in the air the air can hold 16 what is relative humidity?
|
25%
|
|
when air is cooled to the point where it's relitive humidity is 100% and the moisture can condense and separate, we say the air has reached it's ______ _____ temp.
|
Dew Point
|
|
A liquid will _____ heat when it vaporizes or boils, and the vapor will _____ heat when it condeneses.
|
loss, reject
|
|
The colder the air temp the _____ moisture it can hold.
|
less
|
|
What is used to clean the air going through the return vent?
|
Filter
|
|
What does the metering Device do to the refrigerant?
|
Flashes
|
|
The heat that has been absorbed in the Evaporator is rejected in the _______ .
|
Condincer
|
|
What are the four things that air conditioning controls?
|
temp, cerculation,air cleaness, humidity
|
|
The air flowing from the conditioned Space to the Air Conditioning Unit is know as _______.
|
return
|
|
The air flowing from the air Conditioned unit to the conditioned Space is known as _______.
|
Supply
|
|
Refrigerant properties can be classified as ______ and _______
|
Physical, Thermodynamic
|
|
The ________ is the medium that picks up and carries the heat in the Refrigeration cycle.
|
refrigerant
|
|
Thermodynamic Properties are the proerties of the refrigerant that have to deal with the movement of _________
|
Heat
|
|
When moisture is present in a refrigeration system, what two problems will normally occur in the system?
|
Broke metering device
Formation of ACIDS |
|
When a refrigerant saturated with moisture is _______, the water will be released.
|
Cooled
|
|
T/F
Liquid r-22 can be pourwed from a bucket under normal room conditions. |
F
|
|
T/F
The Enthalpy(BTU's) of the saturated gas minus the Enthalpy(BTU's) of the liquid is equal to the latent heat(BTU's) |
T
|
|
T/F
Water and Alcohol are Miscible. |
F
|
|
T/F
R-22 is always a miscible refrigerant. |
F
|
|
T/F
R-22 and R-12 are not toxic therefore they are never dangerous. |
F
|
|
T/F
Will support combustion under certain conditions. |
T
|
|
T/F
The latent heat BTU's and the refrigeration effect BTU'S can be the same for a refrigerant. |
T
|
|
Which of the following iteams are considered accessories to a Manifold Gauge Set?
|
Hanger and Hose Storage Jack
|
|
The process to remove contaminants( air & Moisture) from the manifold and pressure Hoses is called?
|
Purging
|
|
Your Manifold Gauges are connected to an operating unit and both gauge valves are back seated, what happenes to the pressure gauge readings?
|
Low side pressure will go up. high side pressure will go down.
|
|
What are the colors of the high and low side gauges?
|
High- red/low Blue.
|
|
low side markings are in _______ increments?
|
1 pound increments
|
|
High side markings are in _________ increments?
|
5 pound increments
|
|
The center Hose and center chamber on the manifold is used to?
|
Recover & Charge Refrigerant, Evacuate System, Add oil.
|
|
The low side or compound gauge has temp scales and pressure scales indicating?
|
Inches of Vacuum and psig
|
|
The Manifold Gauges are useful as a diagnostic tool because they?
|
Indicate the operating pressures that correspond to the saturation temps.
|
|
If the system is using Schrader Core type access valves the manifold gauge pressure hose must have
|
Some way to depress the Valve stem core
|
|
Manifold gauge pressure hoses should be checked or replaced on a regular basis because.
|
With constant use they become less pliable and can develop leaks
|
|
TO read proper system operating pressures the Maniflod Gauge Valves should be.
|
Fully Front Seated
|