- Front
- Back
How often do we test our hose?
|
Annually
|
|
How do we tag a hose out of sevice? what do we write on the tag?
|
reverse roll,
Tag: Description of damage Date taken out of service Signature of the individual |
|
What is surveyed hose?
|
Hose that is taken out of service by the Fire Department and sent to the Public Works Department for their use.
|
|
How is surveyed hose identified?
|
It has a 1-1.1/2" red dot on each end within 12 inches of the coupling
|
|
How many feet are the hose bundles?
|
100ft
|
|
what is the diameter of the hose bundles?
|
1 1/2"
|
|
How do you measure the hose bundle folds?
|
Use the compartment that it is to be stored in.
|
|
How maney feet from the wye do you begin your fold?
|
2 feet
then fold short/long ect. ect. |
|
How many feet long are the pre-connects?
|
200 feet each
|
|
Which side should the nozzles for the transverse lines end up?
|
A side, front of bed
|
|
How many feet of LDH do the Engines carry?
|
750 as a min.
|
|
When loading the LDH hose which side do you start on?
|
place the female coupling on the tail board next to the 2- 1/2" hose
|
|
What do we use to help us remember the fresno finish?
|
Over
Under Under Over |
|
Where are the nozzles placed for the fresno finish?
|
Both to the out side of the beds
|
|
How do you identify the area of a damaged hose?
|
A rag or flagging may be used to identify the damaged area.
|
|
While using the hose monitor you should set the spikes using a hammer that is at least --??-- oz.?
|
At least 16oz.
|
|
How deep into the ground do you have to set the spikes for the portable monitor?
|
At least 1/8" into the concrete
|
|
What surfaces will the apollo monitor spikes not grip?
|
Metal
Marble or similar hard surfaces |
|
At what point should you sharpen the spikes on the ground monitor base?
|
If the flat ends of the spikes exceed 1/16"
or 1.5mm |
|
What is the maximum safe operating pressure for the portable monitor?
|
200 psi
|
|
When the Apollo monitor is used on the ground what degree is the safety stop at?
|
35 degrees
|
|
When the Apollo monitor is used in the portable base what is the max GPM?
|
500 GPM
|
|
What are the charge the line hand signals for the day time?
|
Raise both arms vertically above the head and hold stationary
|
|
What are the charge the line hand signals for the night time???
|
Raise one arm vertically above the head with flashlight directed towards hydrant man or operator and wave flashlight horizontally above head.
|
|
While calling for water what is our first means for communication?
|
Hand signals
Radios are 2nd |
|
What are the hand signals for water shutdown daytime?
|
Extend both arms down and swing arms in front of body crossing the arms.
|
|
What are the hand signals for water shutdown nightime?
|
Extend one arm down, with flashlight directed towards supply, and swing in front of body.
|
|
What are the hand signals for increasing the water pressure daytime?
|
Extend arms horizontally from shoulders, palms up, raise arms to about 45 degrees.
|
|
What are the hand signals for increasing the water pressure nightime?
|
Extend one arm horizontally from shoulder, with flashlight directed towards operator and raise to about 45 degrees.
|
|
How much PSI is given when you hand signal for increase or decrease in water pressure?
|
10 PSI -per signal
|
|
What is the hand signal for decrease water pressure daytime?
|
Extend arms horizontally from shoulders, palms down, lower arms to about 45 degrees.
|
|
What is the hand signal for decrease in water pressure nightime?
|
Extend one arm horizontally from shoulder, with flashlight directed toward operator and lower to about 45 degrees
|
|
What is the standard PSI setting for the standpipe opertation?
|
150 PSI
|
|
How long is the front bumper pre-connect hose?
|
100ft
|
|
what is the diameter of the front bumper pre-connect?
|
1 1/2 inch
|
|
At what point and how long is your loop for the front bumper pre-connect hose load
|
After first 50 feet make the 2 foot loop.
|
|
In the Gnass hose packs, which ones have a hose clamp?
|
pack 1&2
|
|
In the Gnass hose packs which ones have water tee's?
|
1-4 will all have one on the first hose out attach to the male coupling
|
|
On the Gnass hose packs which color strap do you pull first???
|
BLUE on the Left shoulder
|
|
What color is the second strap that you pull for the Gnass packs?
|
Orange
|
|
What is the diameter, length, and amount of hose on Gnass packs 1-4
|
1 1/2, 100ft sticks, and 200ft total
|
|
Gnass pack number 5 has what diameter hose and how much of it?
|
1" and there is 300ft total
|
|
When rolling the hose for the Gnass packs how far back does the male coupling need to be placed from the female coupling?
|
3 feet
|
|
How should you step off after grabbing hose?
|
By facing foward.
|
|
What direction must the triple fold be pulled off the rig?
|
It can be pulled straight or to the left or right.
|
|
Where shall the nozzle be placed on the accordion shoulder carry?
|
Between the waist and the shoulder.
|
|
How much hose should be on one persons shoulders?
|
50 feet.
|
|
Who is the one to pay off hose first?
|
The person nearest the rig.
|