52 Cards in this Set
- Front
- Back
Engine |
Failure |
|
Tourquemeter & Anti-Icing Shroud |
Failure |
|
Fuel nozzle MIL-L-23699 |
1,800 HR Scrap |
|
Fuel Nozzle 6809611 |
3,000 hr Scrap |
|
Fuel Nozzle 47031 |
3,000 hr Scrap |
|
Fuel Nozzle 523270 |
3,000 hr Scrap |
|
Fuel Nozzle 23074273 |
3,750 hr Scrap |
|
APU and QECAs |
Failure |
|
Rear top Engine Mount |
60 Months |
|
LH Rear Engine Mount |
60 months |
|
NON Reworked Variable Pitch Prop |
Non reworked- 5,000 Hrs
|
|
Reworked Identified by NR Variable Pitch Prop |
New - 7,500 Hrs
|
|
How to tell if prop is reworked? |
S/N's greater than N232925
NR will be stenciled on Each Blade |
|
FWD Side Engine Mount |
60 Months |
|
Valve Housings |
Failure |
|
NLG Shock Strut Assembly |
74 Months |
|
MLG Shock Strut Assembly |
76 Months |
|
MLG Shock Strut |
100 Months |
|
NLG Shock Strut |
100 Months |
|
Pump housing |
Failure |
|
Pneumatic Reservoir (EBB) |
10 Years +/- 10% I level -Proof Press Test |
|
RGB |
Failure |
|
Power Section |
Failure Repair |
|
What engine mount have indefinitely life unless QECA is turned in? |
Dyna-Focal The rebuild at I-level if it has exceeded 60 months |
|
Co2 Fire Extiguishers |
5 Years |
|
Hanlon Fire Extiguishers |
12 Years |
|
Parachute |
2008 Day Turn-in to I level for inspection |
|
Life Raft's |
5 Years Turn-in for Recertification |
|
O2 Cylinder and Valve Assembly |
8 Years |
|
Portable O2 Bottles |
5 Years |
|
O2 manifold |
IMP B/D |
|
O2 Pressure Reducer |
IMP B/D Bench test Required every 730 Days |
|
EEBD |
15 Years |
|
EPOS |
10 Years |
|
APU Container and Valve |
5 Years NOTE: If 5 yrs missed shall not refill until retest |
|
Fire Container and Valve |
5 Years NOTE: If 5 yrs missed shall not refill until retest |
|
APU HRD Cartridge |
Refer to NA11-100-1.1 |
|
High Temp Duel wired Squib |
Refer to NA11-100-1.1
|
|
EDC |
4,000 Hrs NOTE: Does not get 10% |
|
Crypto Battery |
168 Days |
|
Generator |
5000 Hr |
|
APU Generator |
-2 = 5000 hrs 1hr meter = 1hr gen op time -3 = 7500 hrs 1.5hr meter = 1hr gen op time -10 = 7500Hrs 1.5hr meter = 1hr gen op time |
|
What happened if you canibilize a APU generator and move it to a motor or reverse the swap? |
You have to convert the op time of the generator back to the correct 5000hr high time rather than 7500hr for the APU. |
|
SLAB Battery |
3 YRS |
|
BomB Racks |
365 Days |
|
Chrd Pressure switch |
5 Years |
|
Bomb Rack Adapter |
365 Days |
|
Standard wing pylon |
365 Days |
|
Maverick Pylon |
365 Days |
|
Calendar inspections have a +/- how how many days? |
3 days |
|
inspections based on flight hours, cycles or events have a +/- of what percent? |
10% |
|
Do you have to pull the APU generator to replace it after the 7500 high time? If not when do you replace it? |
No , you will replace it after it expires but the next time you drop the APU for maintenance. |