Kisi Pro Voltage |
24V |
|
Kisi Basic Voltage |
5V |
|
Kisi Basic Channels |
10 - 13, 9;14 for bi-stable |
|
Kisi Pro Channels |
1-4 |
|
Can Kisi Pro power a lock? |
Yes, up to 4 amps per board |
|
Can Kisi Basic power a lock? |
No |
|
Fail Secure = ? |
W/power is OPEN w/o power is CLOSED |
|
Fail Safe = ? |
W/power is CLOSED w/o power is OPEN |
|
AC Power |
Alternating current |
|
DC Power |
Direct current |
|
Magnetic lock - fail safe or fail secure? |
Fail safe |
|
Dry contact |
external power source wired directly to relay (Kisi Basic) |
|
Wet contact |
relay provides output power through board (Kisi Pro) |
|
Not black wire = ? |
Power |
|
Black wire = ? |
Ground |
|
"Lead" |
Connection between point A and point B |
|
Glass door usually has what kind of lock? |
Mag Lock |
|
Wiring a reader w/Kisi Basic |
wire common and wire normally closed (You want the circuit to be normally closed. When circuit is open, light goes out on reader and door is open) |
|
Wiring Kisi with a motion sensor |
Kisi is interrupting the already existing series, needs to be wired in between. Kisi doesn't trigger motion sensor. |
|
Can Kisi Basic be wired as a wet contact? |
No |
|
Can Kisi Pro be wired as a wet contact? |
Yes. It can be wired as wet or dry. |
|
When is common used w/wiring Kisi Pro? |
When using an existing system or you're installing Kisi w/an external power supply such as a separate fuse box |
|
Is a Fail Safe wired in series or parallel? |
Series (needs power to stay |