Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
33 Cards in this Set
- Front
- Back
Convert Head In feet to head pressure |
Divide number of feet by 2.304 |
|
Discharge rate |
29.7 x d’2 x ✔️NP |
|
Nozzle reaction for solid streams |
NR= 1.57 x d’2 x NP |
|
Nozzle reaction for Fog Streams |
NR= 0.0505 x Q x ✔️NP |
|
Friction Loss |
FL= CQ’2L |
|
Elevation Pressure loss |
EH= 0.5H |
|
Pump Discharge Pressure |
PDP = NP + TPL |
|
Net Pump Discharge Pressure |
NPDP = PDP - intake reading |
|
3/4” booster |
1100 |
|
1” booster |
150 |
|
1 1/4” booster |
80 |
|
1 1/2” |
24 |
|
1 3/4” with 1 1/2” coupling |
15.5 |
|
2” |
8 |
|
2 1/2” |
2 |
|
3” with 2 1/2” couplings |
0.8 |
|
3” with 3” coupling |
0.677 |
|
3 1/2” |
0.34 |
|
4” |
0.2 |
|
4 1/2” |
0.1 |
|
5” |
0.08 |
|
6” |
0.05 |
|
Standpipe 4” |
0.374 |
|
Standpipe 5” |
0.126 |
|
Standpipe 6” |
0.052 |
|
Condensed Q formula |
FL = Q’2 |
|
Percentage Method |
(Static-residual)(100) / static |
|
Determining maximum lift |
L= 1.13Hg |
|
Pressure Correction |
PC = lift + total intake hose friction loss / 2.3 |
|
Net pump discharge pressure at draft |
NPDP = PDP + PC |
|
Pool capacity |
C = 7.5 x L x W x D |
|
Relay pumping |
P = R / D + 1 |
|
Water shuttle flow rate |
Flow = 0.9 x TS / Trip Time |