Convert Head In feet to head pressure

Divide number of feet by 2.304

Discharge rate

29.7 x d’2 x ✔️NP

Nozzle reaction for solid streams

NR= 1.57 x d’2 x NP

Nozzle reaction for Fog Streams

NR= 0.0505 x Q x ✔️NP

Friction Loss

FL= CQ’2L

Elevation Pressure loss

EH= 0.5H

Pump Discharge Pressure

PDP = NP + TPL

Net Pump Discharge Pressure

NPDP = PDP - intake reading

3/4” booster

1100

1” booster

150

1 1/4” booster

80

1 1/2”

24

1 3/4” with 1 1/2” coupling

15.5

2”

8

2 1/2”

2

3” with 2 1/2” couplings

0.8

3” with 3” coupling

0.677

3 1/2”

0.34

4”

0.2

4 1/2”

0.1

5”

0.08

6”

0.05

Standpipe 4”

0.374

Standpipe 5”

0.126

Standpipe 6”

0.052

Condensed Q formula

FL = Q’2

Percentage Method

(Static-residual)(100) / static

Determining maximum lift

L= 1.13Hg

Pressure Correction

PC = lift + total intake hose friction loss / 2.3

Net pump discharge pressure at draft

NPDP = PDP + PC

Pool capacity

C = 7.5 x L x W x D

Relay pumping

P = R / D + 1

Water shuttle flow rate

Flow = 0.9 x TS / Trip Time