std for fire app. driver operator professional qualifications |
NFPA 1002 |
|
When raised the first elevated streams could raise ______ in the air. |
30ft(9meters) |
|
the triple combination pumper was introduced in _____. |
1906 |
|
If a pump is rated at greater than 1500 gpm it is capable of taking suction through _______ of suction hose and can discharge water in less than ______. |
-20ft
-45 sec |
|
Per NFPA 1901 a pumper shall be equipped with a permanently mounted pump with a minimum rating of _______. |
750 gpm |
|
pumpers must carry a min. of ______ water |
300 gal |
|
a pumper must have at a min. _____ soft suction, _____ of hard suction hose. |
- 15ft
- 20 ft |
|
pumper must be designed with a min. of ____ of enclosed weather resistant storage space. |
40 ft |
|
initial attack fire apparatus must pump at a min of ______. |
250 gpm |
|
Initial attack fire pumper must have a tank which holds a minimum of ________. |
200 gal. |
|
initial attack fire pumper has min _____ enclosed weather resistant compartments. |
22 ft |
|
mobile water supply apparatus or tenders are designed to carry enough water to extinguish most fires that are held to only _______ bedrooms of a home. |
one or two |
|
tenders must have a min. certified capacity of ______ and a min. of ____ enclosed weather-resistant compartment space. |
-1000 gal
-20 ft |
|
Aerials must be equipped with a min. _____ total ground ladders. |
115 ft |
|
aerials must have a min. ______ enclosed weather resistant storage. |
40 ft |
|
a quint must have a pump rated at _____ and a water tank with a min. certified capacity of _____ . |
-1000 GOM
-300 gal |
|
the quint must have ____ ground ladders and ____ enclosed storage. |
-85 ft
-40 ft |
|
special service fir app. must have a min. of _____ enclosed storage |
120 ft |
|
mobile foam fire app. shall have a pump rated at a min. of _______. |
750 GPM |
|
mobile foam fire app. shall be equipped with one or more foam concentrate tanks with min. capacity of ______ |
500 gal. |
|
water in liquid form weighs _____ per gallon. |
8.33 pounds |
|
The volume of water vapor is _____ times greater than that of an equal amount of liquid water. |
1700 times |
|
The three parts of a municipal water system: |
-the water source
_the treatment plant
_the distribution system |
|
in a municipal water system the pressure ranges from _______ at the delivery point. |
-20 to 80 psi. |
|
municipal water large mains : |
primary feeders, carry large amounts of water |
|
municipal water system, smaller mains |
secondary feeders dist. to smaller area |
|
municipal water sys. distributors |
smallest pipes, carry water to users and hydrants |
|
pressure in the system when the water is not moving |
static pressure |
|
pressure in a system during normal consumption |
normal operationg pressure |
|
pressure that remains in the sys. when water is flowing |
residual pressure |
|
pressure acts in all directions equally |
Pascal's law |
|
atmospheric pressure decreases approx. _____ for every _____ above sea level |
-0.5
-1000 |
|
used to measure the flow pressure in psi and calculate the flow in gpm. |
pitot gauge |
|
Combo (fog) nozzles traditionally have a NP of _____ |
100 psi |
|
Low press. fog nozzles rated at ______ |
50 -75 psi |
|
smooth bore hand lines _____ |
50 psi |
|
rotary gear pump is the type of positive displacement pump most commonly used in the fire service as a _____ for a centerfugial pump. |
priming |
|
the most commonly used pump today |
centerfuigal pump |
|
two-stage pump |
most common type of multi-stage pump |
|
the most common power system found in pumps is the ----- |
TRANSFER CASE |
|
The engine oil level is checked after the engine has been turned off for ______ |
15 min |
|
the parking break will engage when break pressure is below ______ |
40 psi |
|
An aerials three recommended tests |
-full fit
-extension
-90 degree rotation |
|
FCSP |
-Fuel
-Choke
-Switch
-Pull
|
|
the process of sending out an emergency response promptly to an address an incident location for a specific purpose. |
Dispatch |
|
Brake required to hold app. on at least ____ grade. |
20% |
|
if the engine does not start in ____ allow the motor _____ before trying again. |
-15 sec
-60 sec |
|
in good driving conditions follow the ______ |
three second rule |
|
in poor weather conditions you should ____ the three second rule |
double to the 6 sec. rule |
|
the distance it takes to recognize the hazard,apply the brakes, and come to a complete stoop. |
stopping distance |
|
distance the app. travels after you recognize the hazard, remove foot from accelerator, and apply brakes |
reaction distance |
|
distance the app travels once brakes are activated until stop |
braking distance |
|
movement of liquid inside a container as the container is moved |
liquid surge |
|
when app. are on the scene they are classed into two catagories: |
-Working- app. being used
-Parked- used as transportation of crew |
|
usually a distance of ____ is sufficient to allow the unit to operate yet remain safe. |
30 feet |
|
all aerial devices should be operated at a min. of _______ from all overhead wires. |
10 feet |
|
MUTCD traffic accident classes: |
-Major
-intermediate - 30 min - 2 hrs.
-minor - less than 30 min. |
|
MVAs are most likely to occur at ____. the number one priority is ______. |
intersections
traffic control |
|
sprinkler systems should be supplied at _______ unless other specified. |
150 psi |
|
atmospheric pressure caused by the weight of the atmosphere _____ |
is 14.7 psi |
|
dependable lift |
the height a column of water can be lifted in a quantity considered sufficient to provide reliable fire flow, generally considered to be 15 ft. |
|
low level strainer used mostly in portable water tank because ______. |
water is clean and wont allow debris into tank |
|
floating strainer |
designed to operate below water scum, above weeds, and silt in water source. require 24" |
|
number one cause of cavitation during drafting |
whirl pool |
|
second leading cause of cavitation during drafting |
plugged intake screen |
|
the _______ is the most important pumper in a relay. |
source pumper |
|
a good rule of thumb is no relay operation should exceed _______ |
800 feet |
|
A _____ allows you to hook into a relay with out shutting down. |
relay valve |
|
foam tetrahedron |
-water
-foam concentrate
-air
-mechanical agitation |
|
foams two basic types |
-chemical
-mechanical
|
|
class B |
-hydrocarbon
-comb. fuels
-polar solvents |
|
protein foams |
class B fires involving hydrocarbons |
|
flouroprotien foams |
subsurface applications to hydrocarbon fuel storage tanks |
|
low expansion |
up to 20:1 |
|
medium expansion |
20:1 200:1 |
|
high expansion |
200:1 1000:1 |