std for fire app. driver operator professional qualifications

NFPA 1002

When raised the first elevated streams could raise ______ in the air.

30ft(9meters)

the triple combination pumper was introduced in _____.

1906

If a pump is rated at greater than 1500 gpm it is capable of taking suction through _______ of suction hose and can discharge water in less than ______.

-20ft



-45 sec

Per NFPA 1901 a pumper shall be equipped with a permanently mounted pump with a minimum rating of _______.

750 gpm

pumpers must carry a min. of ______ water

300 gal

a pumper must have at a min. _____ soft suction, _____ of hard suction hose.

- 15ft



- 20 ft

pumper must be designed with a min. of ____ of enclosed weather resistant storage space.

40 ft

initial attack fire apparatus must pump at a min of ______.

250 gpm

Initial attack fire pumper must have a tank which holds a minimum of ________.

200 gal.

initial attack fire pumper has min _____ enclosed weather resistant compartments.

22 ft

mobile water supply apparatus or tenders are designed to carry enough water to extinguish most fires that are held to only _______ bedrooms of a home.

one or two

tenders must have a min. certified capacity of ______ and a min. of ____ enclosed weather-resistant compartment space.

-1000 gal



-20 ft

Aerials must be equipped with a min. _____ total ground ladders.

115 ft

aerials must have a min. ______ enclosed weather resistant storage.

40 ft

a quint must have a pump rated at _____ and a water tank with a min. certified capacity of _____ .

-1000 GOM



-300 gal

the quint must have ____ ground ladders and ____ enclosed storage.

-85 ft




-40 ft

special service fir app. must have a min. of _____ enclosed storage

120 ft

mobile foam fire app. shall have a pump rated at a min. of _______.

750 GPM

mobile foam fire app. shall be equipped with one or more foam concentrate tanks with min. capacity of ______

500 gal.

water in liquid form weighs _____ per gallon.

8.33 pounds

The volume of water vapor is _____ times greater than that of an equal amount of liquid water.

1700 times

The three parts of a municipal water system:

-the water source



_the treatment plant



_the distribution system

in a municipal water system the pressure ranges from _______ at the delivery point.

-20 to 80 psi.

municipal water large mains :

primary feeders, carry large amounts of water

municipal water system, smaller mains

secondary feeders dist. to smaller area

municipal water sys. distributors

smallest pipes, carry water to users and hydrants

pressure in the system when the water is not moving

static pressure

pressure in a system during normal consumption

normal operationg pressure

pressure that remains in the sys. when water is flowing

residual pressure

pressure acts in all directions equally

Pascal's law

atmospheric pressure decreases approx. _____ for every _____ above sea level

-0.5



-1000

used to measure the flow pressure in psi and calculate the flow in gpm.

pitot gauge

Combo (fog) nozzles traditionally have a NP of _____

100 psi

Low press. fog nozzles rated at ______

50 -75 psi

smooth bore hand lines _____

50 psi

rotary gear pump is the type of positive displacement pump most commonly used in the fire service as a _____ for a centerfugial pump.

priming

the most commonly used pump today

centerfuigal pump

two-stage pump

most common type of multi-stage pump

the most common power system found in pumps is the -----

TRANSFER CASE

The engine oil level is checked after the engine has been turned off for ______

15 min

the parking break will engage when break pressure is below ______

40 psi

An aerials three recommended tests

-full fit



-extension



-90 degree rotation

FCSP

-Fuel



-Choke



-Switch



-Pull



the process of sending out an emergency response promptly to an address an incident location for a specific purpose.

Dispatch

Brake required to hold app. on at least ____ grade.

20%

if the engine does not start in ____ allow the motor _____ before trying again.

-15 sec



-60 sec

in good driving conditions follow the ______

three second rule

in poor weather conditions you should ____ the three second rule

double to the 6 sec. rule

the distance it takes to recognize the hazard,apply the brakes, and come to a complete stoop.

stopping distance

distance the app. travels after you recognize the hazard, remove foot from accelerator, and apply brakes

reaction distance

distance the app travels once brakes are activated until stop

braking distance

movement of liquid inside a container as the container is moved

liquid surge

when app. are on the scene they are classed into two catagories:

-Working- app. being used



-Parked- used as transportation of crew

usually a distance of ____ is sufficient to allow the unit to operate yet remain safe.

30 feet

all aerial devices should be operated at a min. of _______ from all overhead wires.

10 feet

MUTCD traffic accident classes:

-Major



-intermediate - 30 min - 2 hrs.



-minor - less than 30 min.

MVAs are most likely to occur at ____. the number one priority is ______.

intersections



traffic control

sprinkler systems should be supplied at _______ unless other specified.

150 psi

atmospheric pressure caused by the weight of the atmosphere _____

is 14.7 psi

dependable lift

the height a column of water can be lifted in a quantity considered sufficient to provide reliable fire flow, generally considered to be 15 ft.

low level strainer used mostly in portable water tank because ______.

water is clean and wont allow debris into tank

floating strainer

designed to operate below water scum, above weeds, and silt in water source. require 24"

number one cause of cavitation during drafting

whirl pool

second leading cause of cavitation during drafting

plugged intake screen

the _______ is the most important pumper in a relay.

source pumper

a good rule of thumb is no relay operation should exceed _______

800 feet

A _____ allows you to hook into a relay with out shutting down.

relay valve

foam tetrahedron

-water



-foam concentrate



-air



-mechanical agitation

foams two basic types

-chemical



-mechanical


class B

-hydrocarbon



-comb. fuels



-polar solvents

protein foams

class B fires involving hydrocarbons

flouroprotien foams

subsurface applications to hydrocarbon fuel storage tanks

low expansion

up to 20:1

medium expansion

20:1 200:1

high expansion

200:1 1000:1