• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/98

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

98 Cards in this Set

  • Front
  • Back

Displacement of the fifth metacarpel

Boxers

How many bones in the body

206

Name 1

Pedicle

Name 2

Lamina

C1 landmark

Mastoid tip

C2 C3 landmark

Gonion

C5 landmark

Thyroid cartlige

C7 landmark

Vertebra prominens

T1 landmark

2in above sternal notch

T2 T3 landmark

Manubrial notch and superior margin of scapula

T4 T5 landmark

Sternal angle

T10 landmark

Xiphoid tip

L3 landmark

Coastal margin, level of umbilicus

L4 landmark

Illiac crest

S1 landmark

Asis

Coccyx landmark

Pubic symphysis and greater trocanters

Leg rotation for the ankle mortise

15-20

CR entrance point for ap shoulder

1 in below coracoid process

Tube angle for the sunrise view

30°

Term used to describe child abuse

Non accidental trauma NAT

Normal adult creatinine level

.6-1.5

Procedure most effective for demonstrating small polyps in the colon

Double contrast BE

Peristalsis is an example of what type of digestion

Mechanical

How many degrees of rotation is used for oblique SI joints

25-30

Angle for a PA axial clavical

25-30 caudad

Synarthroses

Immovable

Amphoarthroses

Slightly moveable

The navicular is best shown in what exam

Ulnar deviation

The kucheudorf position is used to demonstrate

The patella

Kite position is used for

Clubbed feet

The cuboid bone lies on what side of the foot

Lateral

The innominate bone is

The hip bone

CR for a ap hip

Midfemoral neck

A pt in a diabetic coma needs what (hyperglycemia)

Insulin

Window width

Contrast

During a 2 part conversion system a _____________ converts xray photons to light

Scintillator

1 ma = ___ A

.001

Brightness gain has a range of

5000 to 30000

Input phosphor converts

Xrays to light

Half value layers are measured using

Dosimetry equipment

The active layer of the Dr imaging plate is made up of

Photostimuable fluorohailoids

When the cr imaging plate is scanned the phosphors of the latent image releases energy in the form of

Light

mAs increases, exposure

Increases

mas increases, contrast

Doesn't change

Use a grid when the part measures more than

10 cm

Grid conversion factors

0-1


5-2


6-3


8-4


10-5


12-5


16-6


Mas1=gcf1


Mas2=gcf2

Filtration increases, skin exposure

Decreases

Filtration increases, heam heardness

Increases

Filtration increases, receptor exposure

Decreases

3 factors that contribute to the absorbing ability of a body part

Thickness


Atomic number


Specific gravity

Additive or destructive


Atelectasis

Additive

Additive or destructive


Congestive heart failure

Additive

Additive or destructive


Pleural effusion

Additive

Additive or destructive


Pneumonia

Additive

Additive or destructive


Tb

Additive


Additive or destructive


Acities

Additive

Additive or destructive


Cirrhosid

Additive

Additive or destructive


Bowel obstruction

Destructive

Additive or destructive


Carcinoma

Destructive

Additive or destructive


Gout

Destructive

Additive or destructive


Multiple myeloma

Destructive

Intensifying screens are

Contrast enhancers

Motion has the greatest impact on

Detail

The effective focal spot is _____ than the actual focal spot

Smaller, the reduction in size is called the line focus principal

Angle of the tube causes

Elongation

Angle of the part causes

Forshortening

How to get the best signal to noise ratio

Increase mas


Decrease kvp


Increase collimation

Focusing cup is made of

Molybdenum or nickle

Anode is made of

Tungsten

Leakage radiation should not exceed

100 mR/hr at 1 meter

Back up timer should be set at

150% the anticipated manual exposure time or 600 mas

Ohms law

V=IR


Rem=rad×QF

Electrical circuits operate in

69 cycle AC

Parallel circuit formula

Lowest resistor divided by 2

Series circuit formula

Add all resistors

Turns ratio

Ts/tp

Turns and voltage formula

Vs=ts


Vp=tp

Rectifiers convert

A.C. to DC

Input phosphor is comprised of

Cesium iodide

Photocathode

Converts light photons to electrons

Output phosphor converts

Electrons to light

Output phosphor is made of

Zinc cadmium sulfide

Brightness gain formula

Flux×minification

The active layer in cr is made from

Europium activated barium fluorohalide

Cr is read by

Helium neon laser

Pt scheduling order

Non contrast


Uptake


Urinary


Biliary


Lower


Upper

Pt priority

Stat


Fasting


Ped and geriatric


Diabetic

% of o2 through nasal cannula

21-60

Iv is hung

18 to 20 in

Adult heart rate

60-100

Adult bp

100-140


60-80

Systolic

Beating

Diastolic

Restinh

Respiratory range for adult

30 to 60

Colles fracture

Outward

Smith's fracture

Inward

BUN

8-25

Gfr

90 to 120